Setting the power level (PWR)
The power level setting is the Golden Mask 5 sensitivity. The higher the number, the
deeper the signal goes. But be aware, that on mineralization higher number of power level
does not always mean deeper penetration of the signal. On highly mineralized ground a
higher number of the power level setting could lead to impossibility to ground-balance
the machine and/or reduced depth.
Although the numbers start at 0, a number of 0 does not mean zero sensitivity. With
power level at zero, the detector still has a good depth, so don’t be afraid to lower the
power level, especially on highly mineralized ground this could be the right decision.
Lower power level value also leads to a faster recovery speed.
To set the power level value, press the POWER LEVEL button at the top-right of the control
panel. A new screen with numbers will appear. Select the desired value number by navi-
gating left or right with the - and the + buttons and press ENTER to confirm your choice.
POWER LEVEL
22
23
21
Setting the sound volume
To set the sound options, press the tone button at the middle of the right column on the
control panel of the detector. A screen with options (that you already know from the dual-
tone mode chapter) will appear. Select the VOLUME option and confirm your choice with
the ENTER button.
Now you will see a screen with number. By selecting the desired value, you change the
sound volume. At every push of the button, you will hear a sound. When the sound vol-
ume matches your desired level, confirm with the ENTER button.
SELECT
volume
tone
VOLUME
4
5
3