ELECTROLYTIC CHLORINE GENERATOR
BASIC POOL MAINTENANCE REQUIREMENTS
888-921-POOL
WEEKLY
MONTHLY
QUARTERLY
Free Chlorine 1.0 - 3.0 ppm Turn output dial up to increase,
pH 7.2 - 7.6
down to decrease -OR- increase
Too low - add soda ash.
or decrease pump filtration time.
Too high - add muriatic acid
Alkalinity 80 - 120 ppm
Salt 2700 - 3400 ppm Add salt as required to increase.
Add baking soda to increase.
Stabilizer 60 - 80 ppm Add cyanuric acid to increase.
Calcium 200 - 400 ppm Add calcium to increase.
Electrolytic Cell inspect & clean Refer to section in manual.
TEST IDEAL RANGE ADJUSTMENT REQUIRED
Drain and add water to decrease.
Add acid as required to decrease.
Electronic Chlorine Generator
www.goldlinecontrols.com
N. Kingstown, RI 02852 USA
092009K