- DL manuals
- Goldstein
- Fryer
- FRE-18D
- User Manual
Goldstein FRE-18D User Manual
Summary of FRE-18D
Page 1
Electric fryers proudly australian made installation procedure – user manual service instruction models fre-18d, fre-24d, fret-18d fre-24d fre-18d fret-18d established 1911 the cooking equipment professionals www.Goldsteineswood.Com.Au.
Page 2: Table of Contents
Table of contents 1. Introduction page 3 2. Installation page 4 & 5 3. Commissioning page 6 4. Operating instructions page 7 & 8 5. Draining & filtering instructions page 9 & 10 6. Technical data page 11 & 12 7. Resistance vs temperature page 13 8. Servicing page 14 & 15 9. Trouble shooting page 16 ...
Page 3
1 . Introduction congratulations for purchasing your goldstein commercial cooking appliance. J. Goldstein & co. Is a wholly owned australian company and has been operating since 1911, building high quality products. The information in this manual will assist your installer and ensure correct locatio...
Page 4
2. Installation receiving inspection – pre-installation please follow these instructions carefully • remove baskets and cartons from unit, check contents. • lift off base and screw the adjustable legs into the base. • set units in correct position. • adjust feet till they are all touching the floor ...
Page 5: Caution
2. Installation cont’d please follow these instructions carefully 1. Set unit in desired position. If rear wall is of combustible material ensure there is a minimum distance of 100mm between the back of the unit and the wall. 2. Adjust feet till they are all touching the floor and using a spirit lev...
Page 6: Commissioning Check List
3. Commissioning commissioning appliance – details, testing, checking pressure etc. Commissioning check list 1. Check for damage and missing ports. 2. Remove all plastic coating from s/steel panels. 3. Make sure all parts are in their correct position e.G. Trays elements. 4. Make sure all electric c...
Page 7
4. Operating instructions 1 operating before first use clean protective oil from bright parts and interior of pan with a solution of washing soda or other grease dissolving material. Drain through valve in bottom then rinse thoroughly. (note: it must be completely rinsed out for even a small particl...
Page 8
4. Operating instructions cont’d weekly a) completely drain the fryer vessel into either the filter or steel container. Do not use a plastic bucket or glass container. B) clean the vessel with a good grade of cleaner or hot water and a strong detergent. D) bring to a rolling boil, turn the heat down...
Page 9
5. Draining & filtering instruction a. Draining warning draining and filtering of shortening must be accomplished with care to avoid the possibility of a serious burn caused from careless handling. Warning the element must not be turned on when the fry pot is empty. A few minutes of element operatio...
Page 10
5. Draining & filtering instructions cont’d b. Boiling out the frypots clean new fry pots as follows before filling with shortening: 1. Before operating the element, close fryer drain valve and fill empty fry pot with a mixture of cold water and boil-out washing soda solution. Fill to the fry pot oi...
Page 11
6. Technical data fre-18d-24d fret-18d digital control srt 701 caho im013b2/p11.
Page 12
6. Technical data cont’d srt-701 caho features 1. Terminal design: adopts a special design with strong stress, provide good connection. Its also suitably for vibrating 2. Pcbs: whole series use double sided pcbs, quality can be assured. 3. Pcb’s location: be fixed by vertical type which will not be ...
Page 13
7. Resistance vs temperature rtd sensors - table for platinum resistance elements. R(0) = 100 ohm. Alpha-0.00385. Resistance values in ohms from 0 °c to + 150°c. Pt100 ohm rtd to din 43760 - iec 751 °c 0 1 2 3 4 5 6 7 8 9 0 100.00 100.39 100.78 101.17 101.54 101.95 102.34 102.73 103.12 103.51 10 103...
Page 14
8 servicing accessing fryers for servicing warning moving a fryer filled with hot shortening may cause splattering of the hot shortening. Extreme care must be exercised. Filling fill pan to level indicated on back of pan. The fre-18 size fryer takes approximately 27 litres of oil. The fre-18t takes ...
Page 15
8. Servicing cont’d accessing fryers for servicing warning moving a fryer filled with hot shortening may cause splattering of the hot shortening. Extreme care must be exercised. 1. Switch off main power – electrical lead and remove plug if fitted. 2. Remove restraining devices typically applied to t...
Page 16
9. Trouble shooting trouble shooting. These troubleshooting procedures must be carried out only by a goldstein authorised maintenance & repair centre or company specialising in restaurant cooking appliances. The problems and possible solutions given below cover those most commonly encountered. Facto...
Page 17
10. Wiring diagram – fet18 digital control fet18 digital control n a2 a1 nc micro switch cno main switch main switch contactor n b contactor n a probe tc 3 220 110 n 2 1 17 16 15 element 7.0kw n tc n b a contactor contactor n 220 110 2 3 n 1 probe 16 17 15 over temp. Over temp. Element 7.0kw n other...
Page 18
10a. Wiring diagram – fre-18d – 24d no cn c mi cr o sw it ch a ter m in a l bl oc k b co nt acto r temperature co nt ro ller sr-t 701 p r o be (p t -10 0) e l ements 7.0kw x 3 co nt acto r b a overtem p e r at ur e thermost at wi n g im013b2/p18.
Page 19
11. Drawings fre-18d & 24d model: fre-18/d, fre-24/d 15 14 29 10 12 11 6 18 1 17 26 2 9 3 22 23 31 19 20 30 32 27 16 24 28 7 25 8 13 4 5 9 21 26 7a 27 m013b2/p19.
Page 20
11. Spare parts fre-18d & 24d item no. Code description 1. Mbkfe180 basket – fre18 2. Fre18m02 scrap arrester – 355 x 355 2. Fre24m02 scrap arrester – fre24 3. Frg18p27 basket holder 3. Frg24p27 basket holder 4. Mth00238 control – elec. Overtemp. (238°c) 5. Eswm0006 micro switch 6. Eevm7501 element ...
Page 21
12. Drawing model: fret-18d im013b2/p21 29 13 13 1 3 23 18 22 2 6 21 9 16 26 17 24 28 7 8 5 4 4 24 20 19 11 12 10 14 15 30 31 27.
Page 22
12. Spare parts model: fret-18d item no. Code description 1. Mbkfe180 basket – fre18 2. Fet18m01 scrap arrester 3. Frg18p27 basket holder 4. Mth00238 control – ele overtemp. (238°c) 5. Eswm0006 micro switch 6. Eevm7501 element – 7kw fre18 / fre24 7. Etc00893 control – digital 893 fryer fre-d 8. Esw0...
Page 23
13. Warranty installation must be carried out according to local regulations by qualified trade persons. Isolating switch(es), shut-off valves etc must be within easy reach of the machine for future service and maintenance requirements. If in doubt call goldstein/eswood or their representative for f...
Page 24
14. J goldstein & co pty ltd branches for inquiries please call your nearest state branch: head office 211-213 woodpark road new south wales 2564 phone: 02 9604 7333 fax: 02 9604 5420 victoria queensland unit 13 unit 3 260-264 wickham road 49 logan road moorabbin woolloongabba victoria 3189 queensla...