Golmar Jazz GB2 User manual

Other manuals for Jazz GB2: User Manual
Manual is about: Video Door Entry System Kit 2-wire

Summary of Jazz GB2

  • Page 1

    User manu al code 50122156 t en jazz vesta2-vesta7 rev.0 1 3 7 jazz gb2 video door entry system kit 2-wire installation technology.

  • Page 2

    Jazz gb2 video door entry system kit - house introduction first of all, we thank and congratulate you for purchasing this product. Our commitment to achieving the satisfaction of customers like you is manifested through our iso-9001 certification and the manufacture of products like the one you have...

  • Page 3

    Characteristics - video door entry system with simplified wiring (non-polarised 2-wire bus). - up to 4 access panels (dp-gb2a distributor required for more than one access panel) per installation. - up to 2 apartments per installation. - maximum 6 vesta2 monitors or 4 vesta7 monitors per installatio...

  • Page 4

    Description of the jazz surface panel 4 input for exterior door opening button (cv-, cv+). : contact 'c' for auxiliary device (2nd ac lock release, gate, etc.). : contact 'n.O.' for auxiliary device (2nd ac lock release, gate, etc.). : 12vdc output for golmar dc electric lock. : communication bus (n...

  • Page 5

    5 exploded view of the parts of the panel. Aluminium front electronic module shield description of the door panel: installation of the door panel locate the top of the door panel at a height of 1.65m. The door panel has been designed to withstand diverse environmental conditions. It is however advis...

  • Page 6

    6 removing the metal front: installation of the door panel remove the screw at the bottom of the door panel using the allen key supplied with the product. Wiring the door panel: ap- c1 na1 ap+ cv- busbus cv+ remove the metal front as shown in the drawing. Positioning the door panel: present the shie...

  • Page 7

    7 installation of the door panel codes assigned to the door panel call buttons: button 'p2': codes 16-21. (apartment 2) 2-button door panels only. Button 'p1': codes 0-5. (apartment 1). The sound module's p1 and p2 buttons are assigned with factory codes. - apartment 1, button 'p1': enables codes 0-...

  • Page 8

    8 installation of the door panel description of the configuration jumper: bus important: do not change the configuration jumper's factory position. Description of the door panel illumination leds (for low light conditions): the door panel lighting leds will turn on during a call if the door panel li...

  • Page 9

    9 installation of the door panel setting ringtone operating mode: to configure the door panel ringtone when making a call, follow these steps: see p. 7. - in the configuration dip switch, set dip 1 and dip 2 to off and dip 3 to on. - the card reader illumination will blink slowly. - then with the p1...

  • Page 10

    10 installation of the door panel setting the activation time for cv- and cv+ (lock release) and c1 and na1 (auxiliary device): to change the activation time for the lock release and auxiliary device, follow these steps: see p. 7. - in the configuration dip switch, set dip 1 to on, dip 2 to off and ...

  • Page 11

    Positioning the card reader: positioning the button identification labels: after completing the wiring and configuration work, position the card reader in the electronic module. Fix using the screws supplied. Important: before closing the card reader, make a test call to the apartment(s) to ensure t...

  • Page 12

    12 installation of the door panel closing the door panel: fix the metal front with the screw using the allen key supplied with the product, as shown in the drawing. Once the work is complete, make a test call to the apartment(s) to check it works correctly. Jazz gb2 video door entry system kit - hou...

  • Page 13

    13 installation of the power supply unit installing the fa-gb2/a power supply unit: replace the protective cover once the input terminals have been wired. Please note that current regulations stipulate that the power supply must be protected by a circuit breaker. Connect the fa-gb2/a power supply un...

  • Page 14

    Wiring diagrams: one-apartment installation with vesta2 monitor and golmar dc lock release. 14 lock release 12 vcc/270ma. Max. Ap on 1 2 3 sw1 ( ) 1 ( ) 1 access panel bus code 0 two-apartment installation with 1 vesta2 monitor per house and golmar dc lock release. Configure the end of line in the l...

  • Page 15

    Wiring diagrams: one-apartment installation with vesta2 monitors in parallel (in-out) and golmar dc lock release. 15 two-apartment installation with vesta2 monitors in parallel (in-out) and golmar dc lock release. ( ) 1 distances and cross-sections: a b c configure the end of line in the last monito...

  • Page 16

    Wiring diagrams: one-apartment with 6 vesta2 monitors, 2 dp-gb2a distributors and golmar dc lock release. 16 configure the end of line in the last monitor. Dip 6 to on. ** configu the end of line in re the last distributor. Switch to on. * distances and cross-sections: dp-gb2a a c b c (1) d twisted ...

  • Page 17

    Wiring diagrams: one apartment with 6 vesta2 monitors, 3 d2l-gb2 distributors and golmar dc lock release. 17 configure the end of line in the last monitor. Dip 6 to on. ** remove the jumper from all of the distributors except the last. * set the jumper in this position for 4.3” gb2 monitors of all o...

  • Page 18

    Wiring diagrams: two apartments with 6 vesta2 monitors, 2 dp-gb2a distributors and golmar dc lock release. 18 bus bus bus bus d c b a dp- 2 gb a end of line code 0 ** distances and cross-sections: dp-gb2a a c b c (1) d bus bus bus bus d c b a dp- 2 gb a end of line code 17 ** off apartment 2 apartme...

  • Page 19

    Wiring diagrams: two apartments with 6 vesta2 monitors, 4 d2l-gb2 distributors and golmar dc lock release. 19 bus bus bus bus d2 d1 d2l- gb2 ( ) 2 bus bus bus bus d2 d1 d2l- gb2 off end of line mains 100~240vac n l cn bus (m) bus(pl) fa- 2 gb /a l twisted pair 2x0.75mm 2 twisted pair 2x1mm 2 6 m 0 a...

  • Page 20

    Wiring diagrams : one-apartment installation with vesta7 monitor and golmar dc lock release. 20 lock release 12 vcc/270ma. Max. Ap on 1 2 3 sw1 ( ) 1 ( ) 1 access panel bus code 0 two-apartment installation with 1 vesta7 monitor per house and golmar dc lock release. Configure the end of line in the ...

  • Page 21

    Wiring diagrams: one-apartment installation with vesta7 monitors in parallel (in-out) and golmar dc lock release. 21 two-apartment installation with vesta7 monitors in parallel (in-out) and golmar dc lock release. ( ) 1 distances and cross-sections: a b c configure the end of line in the last monito...

  • Page 22

    Wiring diagrams: one apartment with 4 vesta7 monitors, 1 dp-gb2a distributor and golmar dc lock release. 22 configure the end of line in the last monitor. Dip 6 to on. ** bus bus bus bus bus bus bus bus d c b a dp- 2 gb a end of line on code 3 code 2 code 1 code 0 ** ** ** ** configur the end of lin...

  • Page 23

    Wiring diagrams: one apartment with 4 vesta7 monitors, 2 d2l-gb2 distributors and golmar dc lock release. 23 configure the end of line in the last monitor. Dip 6 to on. ** bus bus bus bus bus bus d2 d1 d2l- gb2 end of line on code 3 code 2 ** ** remove the jumper from all of the distributors except ...

  • Page 24

    Wiring diagrams: two apartments with 4 vesta7 monitors, 2 dp-gb2a distributors and golmar dc lock release. 24 bus bus bus bus d c b a dp- 2 gb a end of line code 0 ** distances and cross-sections: dp-gb2a a c b c (1) d bus bus bus bus d c b a dp- 2 gb a end of line code 16 ** off apartment 2 apartme...

  • Page 25

    Wiring diagrams: two apartments with 4 vesta7 monitors, 2 d2l-gb2 distributors and golmar dc lock release. 25 bus bus bus bus d2 d1 d2l- gb2 ( ) 2 bus bus code 1 code 0 ** ** bus bus code 16 code 17 ** ** bus bus bus bus d2 d1 d2l- gb2 end of e lin on * off end of e lin mains 100~240vac n l cn bus (...

  • Page 26

    Wiring diagrams: 26 bus bus bus bus d c b a dp- 2 gb a end of line off access panel 2 access panel 1 house with distributors house without distributors (up to 4 monitors) (1) video door entry system with 4 access panels, dp-gb2a distributor for door panels and golmar dc lock release. Or mains 100~24...

  • Page 27

    To the fa-gb2/a power supply access panel wiring diagrams: 27 connection of one golmar ac lock release. Important: fit the varistor supplied with the kit directly to the terminals of the lock release. - to switch voltages higher than 12vdc/1a between terminals 'c1' and 'na1' on the door panel, consu...

  • Page 28

    Golmar@golmar.Es www.Golmar.Es sistemas de comunicación s.A. Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice. Golmar s.A. C/ silici, 13 0894...