Good Way HPW-2600G Operating and maintenance instructions manual - Pre-Operating Instructions
PRE-OPERATING INSTRUCTIONS
When unpacking the unit, if you find damage due to shipping, contact Goodway Technologies immediately.
INCOMING WATER SUPPLY
Connect a garden hose to the water inlet of the unit. The water supply must be able to deliver 8 gallons per
minute at a minimum pressure of 5 psi.
OUTGOING (HIGH PRESSURE) WATER
To the water outlet fitting, connect the high pressure hose, trigger gun, extension and a nozzle.
PUMP – OIL
Before operating the pump, check to see that the oil is level with the dot on the sight gauge which is located at
the rear of the pump. The oil level can also be checked using the dipstick which is attached to the oil filler cap.
Ensure that the vent hole in the cap/dipstick is clear of dirt. When oil is required, use #20 or #30 non-detergent
heavy duty oil.
BURNER – FUEL
FILL THE BURNER FUEL TANK WITH #1 OR #2 DIESEL FUEL ONLY
WARNING
DO NOT USE GASOLINE, CRANKCASE OIL, ANY OIL CONTAINING GASOLINE,
OR ANY OTHER VOLATILE SUBSTANCE FOR THE BURNER.
BATTERY
A battery is not supplied with the unit. Install a 12 volt lead acid battery size 16 (e.g. Champion model no.
16B).
CAUTION:
BATTERY MUST BE INSTALLED BEFORE STARTING THE ENGINE.
(THE ENGINE WILL START WITHOUT THE BATTERY INSTALLED, BUT DAMAGE
WILL OCCUR)