Goodman GME95 Technical Manual

Summary of GME95

  • Page 1

    Rt6612024r2 august 2013 gme95 40" up to 96% gas furnace • refer to service manual rs6610004 for installation, operation, and troubleshooting information. • all safety information must be followed as provided in the service manual. • refer to the appropriate parts catalog for part number information....

  • Page 2: Product Identification

    Product identification 2 the model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. Warning warning high voltage! Disconnect all power before servicing or installing this uni...

  • Page 3: Product Identification

    Product identification 3 gme950403bxa* gme950603bxa* gme950805cxa* gme951005dxa* the model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. The united states environmental pr...

  • Page 4: Product Design

    4 product design 3. Installer must supply the following gas line fittings, de- pending on which entrance is used: left -- two 90º elbows, one close nipple, straight pipe. Right -- straight pipe to reach gas valve. Accessibility clearances (minimum) position* front sides rear top flue floor upflow 3 ...

  • Page 5: Component Identification

    5 component identification upflow/horizontal 1 gas valve 2 gas line entrance (alternate) 3 pressure switch 4 gas manifold 5 combustion air intake connection / “coupling” 6 hot surface igniter 7 rollout limit 8 burners 9 flame sensor 10 flue pipe connection / “coupling” 11 flue pipe (internal) 12 pri...

  • Page 6: Component Identification

    Component identification 6 gme95*****xa* note: airflow area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and noise issues. Low v o l t a g e el ec t r ic a l h o l e hi g h v o l t a g e el e c t r ic al h o l e si d e c u t -o u t le f t...

  • Page 7: Product Design

    7 product design t r ip p o in t c o il c o v e r p r essu r e sw it c h c o il c o ver pr ess u r e sw it c h pa r t # t r ip p o in t id b l o w e r pr e ssu r e sw it c h id b l o w e r pr ess u r e sw it c h pa r t # t r ip p o in t co il c o v e r pr es s u r e sw it c h t r ip p o in t id b l ...

  • Page 8: Product Design

    8 product design part number 10123535 10123519 open setting (°f) 150 160 gme950403bxa* 1 gme950603bxa* 1 gme950805cxa* 1 gme951005dxa* 1 auxiliary limit switches part number 10123533 10123517 open setting (°f) 200 210 gme950403bxa* 1 gme950603bxa* 2 gme950805cxa* 2 gme951005dxa* 2 rollout limit swit...

  • Page 9: Product Design

    9 product design coil matches: a large array of amana ® brand coils are available for use with the gmh95 furnaces, in either upflow or horizontal applica- tions. These coils are available in both cased and uncased models (with the option of a field installed txv expansion device). These 95%+ furnace...

  • Page 10: Product Design

    10 product design filters: filters are required with this furnace and must be provided by the installer. The filters used must comply with ul900 or can/ulcs111 standards. Installing this furnace without filters will void the unit warranty. This furnace has provisions for the installation of return a...

  • Page 11: Furnace Specifications

    Furnace specifications 11 1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice c...

  • Page 12

    Blower performance specifications 12 1. Cfm in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling and medium-s...

  • Page 13

    Blower performance specifications 13 30 40 50 60 70 80 90 11 0 12 0 10 0 13 0 14 0 15 0 10 0 90 80 70 60 50 40 30 20 10 o u t p ut bt u/hr x 1 0 0 0 b t u out p ut vs t e m p e r ature rise cha rt te mp erat ur e r is e 6 00 c f m 70 0 900 100 0 11 00 120 0 1 400 160 0 18 00 2 000 2200 24 00 c f m f...

  • Page 14: Wiring Diagrams

    14 wiring diagrams wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. Gme95*****xa* h ig h v o l t ag e! Dis c onnect al l pow e r bef o re servici ng or in s t a l l in g t h is unit . M u l t ipl e po w e r so ur ces m a y be p r esen t . F ...