Goodman GPH1336M43 Series Specifications

Other manuals for GPH1336M43 Series: Installation instructions manual
Manual is about: AIR CONDITIONERS AND HEAT PUMP UNITS GPC/GPH 13 SEER M SERIES WITH R-410A

Summary of GPH1336M43 Series

  • Page 1

    Ss-gph13mc www.Goodmanmfg.Com 2/12 supersedes 8/11 13 seer c ooling c apacity : 34,000 - 57,500 btu/ h h eating c apacity : 33,800 - 57,000 btu/ h standard features • energy-efficient compressor with internal relief valve • fully charged with r-410a chlorine- free refrigerant • eem blower motor; psc...

  • Page 2

    P roduct s pecifications p roduct s pecifications 2 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 3 n omenclature g p h 13 36 m 4 3 a * 1 2 3 4,5 6,7 8 9 10 11 12 brand engineering g goodman minor revision or dis0nc0ons™ engineering packaged unit major revision p voltage designator typ...

  • Page 3

    P roduct s pecifications p roduct s pecifications 2 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 3 s pecifications gph13 36m43** gph13 48m43** gph13 60m43** cooling capacity total btu/h 34,000 48,000 57,500 sensible btu/h 24,140 36,800 40,800 seer / eer 13/10.8 13/11.5 13/11 decibels ...

  • Page 4: — Gph1336M43 **

    P roduct s pecifications p roduct s pecifications 4 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 5 e xpanded c ooling d ata — gph1336m43 ** outdoor ambient t emper ature 65ºf 75ºf 85ºf 95ºf 105ºf 115ºf entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63...

  • Page 5: — Gph1336M43 ** (

    P roduct s pecifications p roduct s pecifications 4 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 5 e xpanded c ooling d ata — gph1336m43 ** ( cont .) outdoor ambient t emper ature 65ºf 75ºf 85ºf 95ºf 105ºf 115ºf entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 6...

  • Page 6: — Gph1348M43**

    P roduct s pecifications p roduct s pecifications 6 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 7 e xpanded c ooling d ata — gph1348m43** outdoor ambient t emper ature 65ºf 75ºf 85ºf 95ºf 105ºf 115ºf entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 ...

  • Page 7: — Gph1348M43** (

    P roduct s pecifications p roduct s pecifications 6 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 7 e xpanded c ooling d ata — gph1348m43** ( cont .) outdoor ambient t emper ature 65ºf 75ºf 85ºf 95ºf 105ºf 115ºf entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67...

  • Page 8: — Gph1360M43**

    P roduct s pecifications p roduct s pecifications 8 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 9 e xpanded c ooling d ata — gph1360m43** outdoor ambient t emper ature 65ºf 75ºf 85ºf 95ºf 105ºf 115ºf entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 ...

  • Page 9: — Gph1360M43** (

    P roduct s pecifications p roduct s pecifications 8 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 9 e xpanded c ooling d ata — gph1360m43** ( cont .) outdoor ambient t emper ature 65ºf 75ºf 85ºf 95ºf 105ºf 115ºf entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67...

  • Page 10

    P roduct s pecifications p roduct s pecifications 10 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 11 e xpanded h eating d ata gph1336m43 ** outdoor ambient temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 mbh 42.5 40.2 37.9 35.4 33.8 32.8 30.4 28.1 23.9 22.1 20.3 19.2 ...

  • Page 11: , H

    P roduct s pecifications p roduct s pecifications 10 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 11 h eat k it e lectrical d ata (b lower o nly , h eat m ode ) model & heat kit usage circuit #1 actual kw / btu@ 240v mca¹ mod² gph1336m43** 3.06 / 3.06 -- -- hkr3-15b 39 / 45 60 / 60 15...

  • Page 12

    P roduct s pecifications p roduct s pecifications 12 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 13 a irflow d ata model speed volts e.S.P (in. Of h₂o) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 gph13 36m43* low 230 cfm 1122 1078 1032 972 915 804 687 558 watts 338 330 321 310 300 283 264 250 me...

  • Page 13

    P roduct s pecifications p roduct s pecifications 12 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 13 d imensions h b d imensions f ilters model w" d" h" b h model dimensions qty. Gph1336m43 47 51 34¾ 16" 32½" gph13mfr102 (for medium models) 16” x 25” x 2” 1 gph1348m43 47 51 42¾ 18" 40...

  • Page 14: — Gph1336M43**

    P roduct s pecifications p roduct s pecifications 14 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 15 w iring d iagram — gph1336m43** wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ w arning high voltage: disconnect all...

  • Page 15: — Gph1348-60M43**

    P roduct s pecifications p roduct s pecifications 14 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com 15 w iring d iagram — gph1348-60m43** wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ w arning high voltage: disconnect ...

  • Page 16

    P roduct s pecifications p roduct s pecifications 16 www.Goodmanmfg.Com ss-gph13mc ss-gph13mc www.Goodmanmfg.Com pb goodman manufacturing company, l.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2012 • goodm...