Haier 1U12LC2VHA Installation Manual - page 8
INSTALLATION
•
Using the OPERATING INSTRUCTIONS, explain to the user how to use the air conditioner (the remote controller, removing
the air filters, placing or removing the remote controller from the remote controller holder, cleaning methods, precautions for
operation, etc.)
•
Recommend that the user read the OPERATING INSTRUCTIONS carefully.
Model Name
Outdoor
1U12LC2VHA
1U18LC2VHA
Indoor
AW12LC2VHA
AW18LC2VHA
Operating Range
Cooling °F(°C)
0~115(-18~46)
0~115(-18~46)
Heating °F(°C)
5~75(-15~24)
5~75(-15~24)
Power Supply
Voltage, Cycle, Phase V/Hz/-
208-230/60/1
208-230/60/1
Outdoor Unit
Compressor Type
DC Inverter Driven Rotary
Maximum Fuse Size A
15
25
Minimum Circuit Amp A
15
15
Refrigerate Line
Connections
Flare
Flare
Liquid O.D. in
1/4
1/4
Suction O.D. in
3/8
1/2
Factory Charge Oz
R410A / 42.32
R410A / 45.86
Maximum Line Length Ft / m
50/15
83/25
Maximum Height Ft / m
33/10
50/15
•
The outdoor unit should be installed at least ½ mile away from the salt water, including seacoasts and inland waterways. If
the unit installed from 1/2 mile to 5 miles away from the salt water, including seacoasts and inland waterways, please follow the
installation instruction below.
•
Install the outdoor unit in a place (such as near buildings etc.) where it can be protected from sea breeze which can damage
the outdoor unit.
•
If you cannot avoid installing the outdoor unit by the seashore, construct a protection wall around it to block the sea breeze.
•
A protection wall should be constructed with a solid material such as
Protection walls
Sea breeze
ODU
concrete to block the sea breeze and the height and the width of the wall
should be 1.5 times larger than the size of the outdoor unit. Also, secure
over 28 in (700mm) between the protection wall and the outdoor unit for
exhausted air to ventilate.
Sea
ODU
•
Install the outdoor unit in a place where water can drain smoothly.
•
If you cannot find a place satisfying above conditions, please contact manufacturer. Make sure to clean the sea water and the
dust on the outdoor unit heat exchanger
Sea breeze
ODU
Sea
ODU
Sea breeze
ODU
Sea
Section 9 - Seacoast Application
Section 8 - System Specifications
Section 7 – Explaining Operation to the End User
E
N
G
L
IS
H