Haier 2HUM14HC03 Operation Manual

Manual is about: SPLIT TYPE

Summary of 2HUM14HC03

  • Page 1

    Please read this operation manual before using the air conditioner. ● keep this operation manual for future reference. Split type room air conditioner operation manual 10 2 3 9 11 parts and functions operation maintenance trouble shooting cautions indoor unit installaion 5 contents 00105 35380 as07g...

  • Page 2

    2 outdoor unit loading of the battery 1 2 3 4 parts and functions indoor unit outlet inlet connecting piping and electrical wiring drain hose remote controller remove the battery cover; load the batteries as illustrated. 2 r-03 batteries, resetting key (cylinder); be sure that the loading is in line...

  • Page 3

    3 operation air flow direction adjustment auto cool dry fan heat 2.Select operation mode press fan button. For each press, fan speed follows: press mode button. For each press, operation mode changes as follows: remote controller: remote controller: press button every time the button is pressed, tem...

  • Page 4

    Operation sleep operation use of sleep function operation mode 1. In cool,dry mode sleep operation starts sleep operation stops sleep operation starts sleep operation stops approx.6hrs 1 hr 1 hr 1 hr 3 hrs 3 hrs rises 1 o c rises 1 o c rises 1 o c temp.Setting temp.Setting unit stop unit stop in coo...

  • Page 5

    5 operation set clock correctly before starting timer operation. 1.After unit starts, select your desired operation mode. 2.Press timer button to change timer mode. Every time the button is pressed, display changes as follows: remote controller: blank timer on timer off timer on-off then select your...

  • Page 6

    Indoor unit installaion driver ƽ torque wrench ƽ (17mm,22mm,26mm) nipper ƽ reamer ƽ hacksaw ƽ pipe cutter ƽ gas leakage detector or ƽ soap-and-water solution hole core drill ƽ flaring tool ƽ spanner(17,19 and 26mm) ƽ knife ƽ measuring tape ƽ necessary tools for installation power source before inser...

  • Page 7

    Indoor unit installation fix to side bar and lintel a mounting bar, which is separately sold, and then ƽ fasten the plate to the fixed mounting bar. Refer to the previous article, “ when the mounting plate is ƽ position of wall hole. Make a hole of 60 mm in diameter, slightly descending to outside th...

  • Page 8

    1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not co...

  • Page 9

    9 setting of proper room temperature close doors and windows during operation if the unit is not to be used for a long time, turn off the power supply main switch. Use the timer effectively use the louvers effectively do not block the air inlet or outlet proper temperature during cooling operation p...

  • Page 10

    The power supply cord and so on. 2. Do not install in the place where there is any possibility of inflammable gas leakage around the unit. 3.Do not get the unit exposed to vapor or oil steam. Cautions please call sales/service shop for the installation. Do not attempt to install the air conditioner ...

  • Page 11: Haier Group

    Trouble shooting normal performance inspection noise is heard phenomenon cause or check points the system immediately. Smells are generated. Mist or steam are multiple check poor cooling when unit is stopped, it won't restart elapsed to protect the system. When the electric plug is pulled out and re...