Haier AB092XCERA Operation And Installation Manual

Other manuals for AB092XCERA: Service Manual
Manual is about: X MULTI SERIES

Summary of AB092XCERA

  • Page 1

    No.0010577258 a r410a multi split series room air conditioner operation & installation manual ab092xcera ab122xcera ab142xcera ab182xcera please read this manual carefully before usingthis air conditioner. Please keep this manual safely for future use. Cassette type indoor units.

  • Page 2: Contents

    Contents cautions ........................................................................................... Main points of operation................................................................ Parts and functions ........................................................................... Safet...

  • Page 3: Cautions

    Cautions 1 for the purpose of safety, the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight o...

  • Page 4: Specifications

    2 all electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sha...

  • Page 5: Main Points of Operation

    3 main points of operation operation of air conditioner when the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode. 3-minute protection function if restart the unit immediately after stopping, the compressor will start only 3 minutes later to protect ...

  • Page 6: Main Points of Operation

    4 main points of operation prevent cool air blowing off in heating mode,the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off. Defrosting function in heating mode, when frost formed on the outdoor heat exchanger, the air conditioner will automatically defr...

  • Page 7: Parts and Functions

    5 parts and functions swing louver (air flow direction can be adjusted by using the swing button on the remote controller) air inlet grille air filter (inside of the inlet grille) operating control panel.

  • Page 8: Safety Cautions

    6 below are listed four kinds of safety cautions and suggestions: be sure to conform with the following important safety cautions. The safety cautions should be at hand so that they can be checked at any time when needed. If the air conditoner is transferred to the new user, this manual should be as...

  • Page 9: Safety Cautions

    7 warning no goods or nobody is permitted to be placed on or stand on outdoor unit. Donít clean air conditioner with water. Safety cautions the falling of goods and people may cause accidents. Don't operate the air conditioner with damp hands. Otherwise will be shocked. Only use correct type fuse. M...

  • Page 10: Maintenance

    8 maintenance clean the unit turn off the power supply switch do not touch with wet hand. Do not use hot water or volatile liquid the 4 fixed bolts must be loosed as shown in the figure by arrow if they are bolts, the method is that: push the blots inward till to another edge. Clean the air filter c...

  • Page 11: Maintenance

    9 seasonal reserve operate the unit with fan mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover t...

  • Page 12: When Trouble Happens

    10 when trouble happens insufficient cooling or heating the operation controller adjusted as required air filter too dirty ? Horizontal swing louver upward ? (in heat mode) any obstacle exists at the air inlet or outlet? Door or window left opened ? Insufficient cooling any other heat sources in the...

  • Page 13: Customer Need-to-Know

    11 customer need-to-know customer need-to-know please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual f...

  • Page 14: Installation Procedures

    12 1.Selection of installation place (1) place above the ceiling where have enough space to arrange the unit. (2) place where the drainage pipe can be arranged well. (3) place where inlet and outlet air of indoor and outdoor unit will not be blocked. (4) do not expose the unit to the place with heav...

  • Page 15: Installation Procedures

    13 (3) install a suspending bolt to support the unit weight ,anchor bolt should be used in the case of already exists ceiling. Fow new ceiling, use flush-in type bolt, built-in type bolt or parts pretared in the field. Before going on installing, adjust space to ceiling. 3. Installation of indoor un...

  • Page 16: Installation Procedures

    14 4. Installation of water drainage pipe (1) install water drainage pipe pipe diameter shall be equal or larger than that of connecting pipe (pipe of polythene; size: 25mm; o.D.: 32mm ) drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming. If downward slop...

  • Page 17: Installation Procedures

    15 6. Installation of ornament panel install ornament panel on indoor unit (1) check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the ornament panel. (2) fa...

  • Page 18: Installation Procedures

    16 7. Piping connection (1) dimension of connecting pipe (2) the maximum length and drop height of connecting pipe cautions for piping connection smear refrigerant oil on the joints of piping and flare. The bending radius shall be as large as possible. Align the pipe center when fastening, and tight...

  • Page 19: Installation Procedures

    8.Electrical wiring wiring methods: 1 wiring method of ring terminal for connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and pass it through the end ring of connecting line,then connect it to the terminal block and tighten screw. Wiring method ...

  • Page 20: Instructions to Installation

    18 1.There are two methods to set the communication address a. Use the remote controller(default status in first installation). B. Use dip switches on the indoor unit pcb. 2. Address setting procedure when using the remote controller. A. Set the addresses only after the successful installation of th...

  • Page 21: Instructions to Installation

    4. How to check the addresses? When finish all the above works, please power off and power on again to the whole system but set all the indoor units in standby. Then continously press the emergency switch until you hear the buzzer sound 5 times(pi pi pi pi pi), and then the timer led board will show...

  • Page 22: Trouble Shooting

    20 the followings are not malfuncition hua hua trouble shooting water flowing sound is heard when the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì bi- bi-î or ìgodo-godoî. It is the flowing sound of the...

  • Page 23: Trouble Shooting

    21 **? On off air does not blow or the fan speed cannot be changed during drying. In dry mode, when room temperature becomes 2 c higher than temperature setting, unit rill run intermittently at lo speed regardless of fan setting during heating,indoor fan is still running even unit is stopped. To get...

  • Page 24: Trouble Shooting

    Note: 1. Please contact the installers or distributors when trouble happens to repair it. 2. Turn the power off and power on again, if the failure code recurs, please inform the franchiser. 3. Failrue codes maked with are resumable. Abnormal communication between wired controller and indoor unit pcb...

  • Page 25

    Haier group qingdao haier air conditioner electric co., ltd. Address: haier garden, qianwangang road, economic development zone, qingdao, shandong 266555, p.R.China web site: http://www.Haier.Com.