Haier AB142ACNBC Operation Manual - Specifications
All electrical repairs must be carried
out by qualified electricians. Inadequate
repairs may result in a major source of
danger for the user of the air
conditoiner.
Do not damage any parts of the air
conditioner that carry refrigerant by
piercing or perforating the air
conditioner's tubes with sharp or
pointed items, crushing or twisting any
tubes, or scraping the coatings off the
surfaces. If the refrigerant spurts out
and gets into eyes, it may result in
serious eye injuries.
Do not obstruct or cover the
ventilation grille of the air conditioner.
Do not put fingers or any other things
into the inlet/outlet and swing louver.
Do not allow children to play with the
air conditioner. In no case should
children be allowed to sit on the
outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
Cooling
Indoor
Maximum:
Minimum:
D.B / W.B
D.B /
D.B
Outdoor
Maximum:
Minimum:
D.B
43 C/ 26 C
15 C
18 C/ 14 C
32 C/ 23 C
Cautions
Other Instructions
*
2. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similar qualified person.
3. If the fuse on PC board is broken please
change it with the type of T 3.15A /250VAC.
4.
Use copper wire only. The connecting cable
should be H05RN-F4G(3X2.5+1X0.75)mm
2
2
********
The power cable should be H05RN-F 3G 2.5mm.
5. The wiring method should be in line with
the local standard.All the cables shall have
got the European authentication certificate.
6. The air breaker should be all-pole switch.
and the distance between it's two
connecters should no less than 3mm.
7. Air conditioner must use special power supply
system (above 20A), and qualified electrician
makes wiring and fixing according to wiring
regulations specified in national standard.
8. In socket, exactly distinguish earth wire with
neutral wire and it is wrong to connect them
together.
9. A leakage breaker must be installed.
10. Connection method is Y-connection .If the
power cord is damaged, it must be replaced
by professional people of manufacturer or its
maintenance department or similar to avoid
dangers.
11. The air breaker and the power switch should
installed the conveniently reachable place for
user.
Attention:
As a result of poor conditions of the electrical
MAINS, shortly voltage drops can appear
when starting the EQUIPMENT. This can
influence other equipment (et.Blinking of a
lamp). If the MAIN-IMPEDANCE Zmax< 0.
4624277HM, such disturbance are not
expected. In case of need , you may contact
your local supply authority for further
information.
Attention:
1. The waste battery shall be disposed properly.When
throw away the waste batteries, please perform in
accordance with the local regulation.
2. The indoor unit installation height is at least 2.5m.
certificate.