Haier AD122ALEAA Operation & Instruction Manual

Other manuals for AD122ALEAA: Operation Manual And Installation Manual
Manual is about: DUCT TYPE 20Pa INDOOR UNIT

Summary of AD122ALEAA

  • Page 1

    Operation & instruction manual no. 0010577975 b duct type air conditioner ad122alera ad182alera ad242alera ad122aleaa ad182aleaa ad242aleaa please read this operation manual before using the air conditioner. Please keep this manual carefully and safely..

  • Page 2: Table of Contents

    1 table of contents malfunction 7-8 care and maintenance 9 for preparation of heating 10 is the unit installed correctly 11 installation manual for indoor unit 12-21 safety precautions 3-5 parts and functions 6 cautions 2 22-23 failure code.

  • Page 3: Cautions

    Cautions 2 all electrical ropairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes...

  • Page 4: Safety Precautions

    Safety precautions before starting to use the system, read carefully this"safety precautions" to ensure a proper operation of the system. Safety precautions described here are classified to " warning" and " caution". Precautions which are shown in the column of " waning" means that an improper handi...

  • Page 5: Safety Precautions

    4 caution do not wash the air conditioner with water. Do not install the system where the air outlet reaches directly the flora and fauna. Make sure to use a fuse of proper electric rating. Do not operate the system while the air outlet grill is removed. It is strictly prohibited to place a containe...

  • Page 6: Safety Precautions

    5 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3. If the fuse on pc board is broken please change it with the type of t 3.15a /250vac. 4. The wiring method should be in line with the local wiring standard. 1. Applicable...

  • Page 7: Parts and Functions

    Parts and functions 6 electrical components case drain pan evaporator air outlet frame.

  • Page 8: Malfunction

    Please check the following things about your air conditioner before making a servie call. Unit fails to start on off is the power source switch adjust cut in? Is city supply power in normal? Power stoppage? Isn't the signal receiving section exposed to the direct sunlight or strong illumination? Isn...

  • Page 9: Malfunction

    8 the followings are not malfunction shuru shuru when the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble. Wa...

  • Page 10: Care and Maintenance

    9 care and maintenance points to observe turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. On off thinner do not use! Benzine tooth powder cleaning caution do not dry the air filter with fire. Do not run the air conditioner without the air filter. ...

  • Page 11: For Preparation of Heating

    10 for preparation of heating "hot keep"is operated in the following cases. When heating is started: in order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room piping temperature when heating operation is started. Wait for approx. 2 to 3 minute, and the operation...

  • Page 12

    11 is the unit installed correctly for inspection and maintenance when you change your address or the installation place electric work confirm the following items for safe and comfortable use of air conditioner. The installation work is to be burden on the sales dealer, and do not conduct it by your...

  • Page 13: 1.  Safety Precautions

    12 installation manual for indoor unit 1. Safety precautions warning please read these "safety precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, and , those points which are related to the strong possibi...

  • Page 14

    13 installation manual for indoor unit the indoor unit shall be installed at locations where cold and hot air could evenly circulated. The following locations should be avoided: places with rich saline matters (seaside regions). Places with plenty of gas sulfides (mainly in warm spring areas where t...

  • Page 15

    14 installation manual for indoor unit a b c d e f g h i fig 2 after selecting the unit installation location, proceed the following steps: 1. Drill a hole in the wall and insert the connecting pipe and wire through a pvc wall-through tube purchased locally. The wall hole shall be with a outward dow...

  • Page 16

    15 installation manual for indoor unit each of the air sending duct and air return duct shall be fixed on the prefabricated panel of the floor by the iron bracket. The recommended distance between the edge of the air return duct and the wall is over 150mm. The gradient of the condensate water pipe s...

  • Page 17

    16 installation manual for indoor unit installation of indoor unit duct 1. Installation of air sending duct this unit uses rounded duct, the diameter of the duct is 180mm. The rounded duct needs to add a transition duct to connect with the air-sending duct of indoor unit, then connect with respectiv...

  • Page 18

    17 installation manual for indoor unit installing the suspension screw: use m8 or m10 suspension screws (4,prepared in the field)(when the suspension screw height exceeds 0.9m,m10 size is the only choice).These screws shall be installed as follows with space adapting to air conditioner overall dimen...

  • Page 19

    18 installation manual for indoor unit in order to drain water normally, the drain pipe shall be processed as specified in the installation manual and shall be thermal insulated to avoid dew generation. Improper hose connection may cause indoor water leakage. Requirements the indoor drain pipe shall...

  • Page 20

    19 installation manual for indoor unit double-spanner operation for series 122 182 for series 242 in installation, if there is refrigerant gas leakage, please take ventilation measures immediately. The refrigerant gas will generate poisonous gas upon contacting fire. After installation, please verif...

  • Page 21: Electric Wiring

    20 installation manual for indoor unit the notch upward(attached detail view) indoor unit subsidiary insulation tube field piping side electric wiring warning danger of bodily injury or death turn off electric power at circuit breaker or power source before making any electric connections. Ground co...

  • Page 22

    21 (2) wiring connection make wiring to supply power to the outdoor unit, so that the power for the indoor unit is supplied by terminals. 30ma item phase switch breaker (a) circuit breaker overcurrent protector rated capacity (a) power source wire size (minimum) 1 40 26 2.5mm 2 switch breaker earth ...

  • Page 23: Failure Code

    22 resumable if lower than 100 degree for remote type, flash times 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 failure description indoor ambient temp. Sensor failure indoor coil temp. Sensor failure outdoor ambient temp. Sensor failure outdoor coil temp. Sensor failure over -current prote...

  • Page 24: Failure Code

    23 for remote type, flash times 1 2 3 4 5 6 8 9 10 11 12 13 15 17 18 19 20 failure description indoor ambient temp. Sensor failure indoor coil temp. Sensor failure outdoor ambient temp. Sensor failure outdoor coil temp. Sensor failure/compressor dischar ging temp. Sensor abnormal over -current prote...

  • Page 25

    Haier group qingdao haier air conditioner electric co., ltd. Address: haier garden ,qianwangang road , economic development zone, qingdao ,shandong 266500, p.R.C web site: http://www.Haier.Com.