  • Page 1

    Indoor unit r410a multi split series room air conditioner no.0010578129 a please read this manual carefully before using this air conditioner. Please keep this manual safely for future use. Installation manual af092xcera af122xcera.

  • Page 2: Contents

    Contents parts and functions operation hints maintenance installation manual of room air conditioner trouble shooting cautions 1-4 5-6 7 8 9 10-16.

  • Page 3: Cautions

    1 cautions for the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straig...

  • Page 4: Cautions

    2 cautions the machine is adaptive in following situation cooling heating indoor outdoor rated maximum minimum 27 32 18 19 23 14 35 43 10 24 26 6 20 27 15 14.5 -- -- 7 24 -15 6 18 -- db c wb c db c wb c indoor outdoor db c wb c db c wb c model af072xcera communication cable (sheilded wire) power cab...

  • Page 5: Safety Instruction

    3 please read the following safety instructions carefully prior to use. The instructions are classified into two levels, warning and caution according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Safety instruction ...

  • Page 6: Cautions

    4 cautions strict enforcement when abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Connect power supply cord to the outlet completely. After installed, the unit shall be tested for electric leakage. Take care not to damage the power supply cord. D...

  • Page 7: Parts and Functions

    5 parts and functions power timer run on/off remote controller's infrared receiver emergency and test switch "power" lamp (green) it lights up when the indoor unit is started. "timer" lamp (yellow) it lights up when "timer" function is acticated for programmed start/stop. "run" lamp (red) it lights ...

  • Page 8: Parts and Functions

    6 parts and functions on/off button remote controller's receiver room temperature sensor remote controller's infrared receiver it allows the reception of signals sent by the remote controller. If the signal is received, the unit emits a "bip" confirmation sound. On/off button when the remote control...

  • Page 9: Operation Hints

    7 power failure resume (please set and apply as necessary) with setting of power failure resume, if sudden power failure occurs, the unit will resume original operation when power is supplied again. Operation hints emergency operation carry out this operation only when the remote controller is defec...

  • Page 10: Maintenance

    8 maintenance cleaning of the unit take off the air inlet grill first switch off the power supply,take off the screw cap,loosen the screw with cross screwdriver . Clean the filter use water or vacuum cleaner to remove dust. If it is too dirt, clean with detergent or neutral soap water. Rinsing with ...

  • Page 11: Trouble Shooting

    9 trouble shooting is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(use curtain...

  • Page 12

    10 installation of indoor unit selection of installation place fig1 330 617 fig2 fig3 more than more than more than more than tool necessary installation manual of room air conditioner place where it is easy to route drainage pipe and outdoor piping. Place ,away from heat source and with less direct...

  • Page 13: Fixing of The Unit

    11 fixing of the unit 1. Position of the wall hole wall hole should be decided according to installation place and piping direction.(refer to installation drawings). 2. Making a wall hole drill a hole of 120x70mm dia. With a little slope towards outside. 3. Piping connection threads on the pipes may...

  • Page 14

    12 1. Arrangement of piping and drainage pipe after opening inlet grill,you will see a control box. Remove the cover before working. Cut away, with a hammer or a saw, the lid for piping according to piping direction. According to the piping method, connect the piping on indoor unit with union of con...

  • Page 15

    13 others the power plug should be connected as follows: l for live line, n for neutral line and for grounding. The signal wire must be shielded wire. 2. Piping cutting and flaring be sure to carry out deburring after cutting with a pipe cutter. Insert flaring tool to make a flare. Installation manu...

  • Page 16

    14 remove air intake screen and take out the front wires. Connect the wires as specified in the above methods and diagrams for indoor unit and wire con- nections. Properly apply capping clips on the wires. Replace the air intake screen. Do not link the connecting and signal wire with the same cable,...

  • Page 17

    15 indoor unit communication addresses setting caution! Fail to do this, the unit will not work. 3. Address setting procedure when using the dip switches sw01 and sw02. A. The dip switches sw01 and sw02 are on the indoor unit pcb. B. Before carrying out the address setting work, the system must be p...

  • Page 18

    16 when finish all the above works, please power off and power on again to the whole system but set all the indoor units in standby. Then continously press the emergency switch until you hear the buzzer sound 5 times(pi pi pi pi pi), and then the lcd display board will show the address of this indoo...

  • Page 19

    Haier group qingdao haier air conditioner electric co., ltd. Address: haier garden, qianwangang road, economic development zone, qingdao, shandong 266555, p.R.China web site: http://www.Haier.Com.