Haier AP182ACBEA Operation And Installation Manual - page 14
13
Tool necessary
1. Screw driver
2. Hacksaw
3. 70mm dia.hole core drill
4. Spanner(dia. 17,27mm)
5. Spanner(14,17,27mm)
6. Pipe cutter
7. Flaring tool
8. Knife
9. Nipper
10. Gas leakage detector
or soap water
11. Measuring tape
12. Reamer
13. Refrigerant oil
Following parts shall be field
supplied
Mark
Part name
Adhensive tape
Pipe clip
Connecting hose
Insulation material
Putty
Drain hose
A
B
C
D
E
F
Note: There isn't connecting wire with this unit.
Fixing of the unit
1. Position of the wall hole
Wall hole should be decided according to installation
place and piping direction.(refer to installation drawings).
2. Making a wall hole
Drill a hole of 120X70mm dia. with a little slope towards
outside.
Indoor side
Outdoor side
Thickness
of wall
Wall hole
70mm
(Cross section of wall hole)
Installation Manual