Haier AP242ACBEA Operation And Installation Manual

Other manuals for AP242ACBEA: Service manual
Manual is about: Commercial Air Conditioning 24 28 Universal Outdoor Unit air conditioning

Summary of AP242ACBEA

  • Page 1

    Ap242acbea ap42nacbea please read this operation manual before using the air conditioner. No.0010573531 e operation & installation manual cabinet type air conditioner please keep this manual carefully and safely..

  • Page 2: Content

    Operation content cautions parts operation operation hints energy saving maintenance trouble shooting when problems occur indoor & outdoor unit connection tools necessary installation procedures others 6-11 13 14-15 16 17-18 19 20 21-26 27 12 1-2 3-5.

  • Page 3: Cautions

    Cautions 1 disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, wh...

  • Page 4: Cautions

    2 the machine is adaptive in following situation applicable ambient temperature range: cooling heating indoor outdoor rated maximum minimum 27 32 18 19 23 14 35 43 10 24 26 6 20 27 15 14.5 -- -- 7 24 -7 6 18 -- db c wb c db c wb c indoor outdoor db c wb c db c wb c cautions for the purpose of safety...

  • Page 5: Parts

    Parts 3 1 2 3 4 1 outlet grill 2 operation panel 3 inlet grill 4 air filter [inside the unit] 5 remote-controller indoor unit 5 am timer clock set time time sleep low mid high set temp c temp temp swing mode fan speed on off : fresh high/so timer set filter b a m d health reset lock sleep fan temp o...

  • Page 6: Parts

    Parts 4 25 26 21 23 36 fresh high/so timer set filter b a m d health reset lock sleep fan temp on off swing mode clock code light off a u t o 1 2 3 4 6 7 9 10 13 17 15 5 8 18 19 22 34 33 24 27 28 32 31 30 35 20 14 16 remote controller 1.Temp setting button (used to set temperature. Setting ranges: 1...

  • Page 7: Parts

    5 am timer clock set time time sleep : 1 3 2 clock set displays when healthy run function is set. 22.Temperature display 34.Lock state display 33.Battery energy display notify the user when it is time to change the batteries. 24.Hign/so run display 26.Signal sending display 28.Fresh display 29.Auxil...

  • Page 8: Operation

    6 operation auto, cool , heat and dry operation 1. Unit start press on/off button,unit starts. Previous operation status appears on lcd (except for timer,sleep and swing setting) 3.Temperature setting then select auto run or select cool operation or select dry operation or select heat operation 2.Se...

  • Page 9: Operation

    7 operation fan operation 1.Unit start press on/off button to start your air conditioner. Previous operation status appears on lcd (except for timer, sleep, and swing setting). 2.Select operating mode press mode button. At each press, operation mode changes as follows: 3. Adjust fan speed press fan ...

  • Page 10: Operation

    8 operation swing louvers (vertical louvers) horizontal louvers (adjust by hand) up and down adjust the louvers by hand to proper position. Put louvers at up position in cooling and down position in heating mode. This will be helpful to keep an even room temp. Note: in cooling or dry operation, don'...

  • Page 11: Operation

    Sleep function before going to bed you can press down the sleep button and the air conditioner will run so as to make you sleep more comfortably. Before using this function, the clock must be set. Use of sleep function after the unit's start, set running mode and then press sleep button once to make...

  • Page 12: Manual Operation

    Every time the button is pressed, time increases 10 minuts. If the button is kept pressed, time changes quickly. Timer on/off function set clock correctly before starting timer operation 1.Unit start after unit start, select your desired operation mode (operation mode will be displayed on lcd) 2.Tim...

  • Page 13: Manual Operation

    Manual operation remote controller operation 11 operation timer on-off function set clock correctly before starting timer operation 1.Unit start after unit start, select your desired operation mode (operation mode will be displayed on lcd) 2.Timer mode selection press timer button on the remote cont...

  • Page 14: Unit  Operation

    Unit operation protection devices inside the unit will activate to stop unit operation, when ambient temp. Is extremely low or high. When unit is running under high humidity in cooling or dehumidifying mode, condensate might appear at outlet grill. 3-min delay protection fan speed changes cold draft...

  • Page 15: Energy Saving

    13 energy saving keep proper room temp. Too cold or too warm is no good to your health, and power consumption will be increased as well. Air filter should be periodically cleaned if air filter is clogged: it will cause poor cooling and heating efficiency, higher power consumption and even problem ma...

  • Page 16: Maintenance

    14 don't spray any paint or insecticide on the unit. Don't splash water directly on indoor unit. This will cause damage or even fire accident. This could be very dangerous maintenance disconnect power supply don't touch it with wet hand don't wash with hot water or solvent to clean the unit don't us...

  • Page 17: Maintenance

    15 maintenance after season maintenance before season maintenance let the unit run in fan mode for half a day in a fine weather to dry completely the unit inside. Turn off the unit and pull out power plug. There might be certain power consumption even if unit is stopped. Clean air filter and indoor ...

  • Page 18: Trouble Shooting

    16 trouble shooting followings are not problems sound of water flowings are not problems. Sound of cracking is heard. Smells are generated. During operation, white fog or steam comes out of indoor unit. In cooling operation, unit switches to fan operation. Unit will not restart after stop. Won't sta...

  • Page 19: When Problems Occur?

    17 when problems occur? Before ask for services, please first check your unit against following. Air conditioner won't start. Is power supply switch turned on? Power supply switch is not set at on. Are operation controlls adjusted correctly as specified? Are horizontal louvers at up position (in hea...

  • Page 20: When Problems Occur?

    18 when problems occur? 2. Power supply air conditioner must use an exclusive line (over 30a) when installation air conditioner in a wet place, try to use a circuit breaker against current leakage. For installation in other places, use circuit breaker as far as possible. Such means for disconnection...

  • Page 21

    19 indoor & outdoor unit connection power cable length approx 1.5m approx 2m pipe direction left rear right bottom over 10cm over 10cm over 10cm over 10cm over 10cm over 60cm over 15cm over 100cm.

  • Page 22: Tools Necessary

    20 tools necessary tools necessary 1. Screw driver 2. Hacksaw 3. 70mm dia. Hole core drill 4. Spanner (dia. 17, 27mm) 5. Spanner (dia.14, 17, 27mm) 6. Pipe cutter 7. Flaring tool 8. Knife 9. Nipper 10. Gas leakage detector or soap water 11. Measuring tape 12. Reamer 13. Refrigerant oil following par...

  • Page 23: Installation Procedures

    21 installation procedures display of whole unit installation of outdoor unit 190 380 190 580 installation dimension of outdoor unit (mm) try to bring the packed unit to the installation place. When it is inevitable to unpack the unit, be careful not to damage the unit. Wrap it with nylon etc. After...

  • Page 24: Installation Procedures

    22 installation procedures installation of indoor unit selection of installation place place where it is easy to route drainage pipe and outdoor piping. Place away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evenly to every corner of the room. Pla...

  • Page 25: Installation Procedures

    23 installation of fall-prevention fitting metal: fix the fitting metal to the wall by screws so that there is no clearance between them. With the unit set up vertically, fix the fitting metal to the unit with screws while making an adjustment at the long portion of the hole so that there is no clea...

  • Page 26: Installation Procedures

    24 2. Piping connection of indoor unit arrangement of piping and drainage pipe after opening inlet grill, you will see a control box as shown in the fig. Remove the cover before wiring work. Cut away, with a hammer or a saw, the lid for piping according to piping direction. Insulation material coppe...

  • Page 27: Installation Procedures

    25 3. Piping connection of outdoor unit. Connect the connecting pipe and inlet and outlet liquid pipe according to the piping method. When piping is longer than 5 m, charge additional refrigerant specified in this list. Pipe length refrigerant charge (g) 5m 10m 15m 20m 650 975 325 4.Purging method d...

  • Page 28: Installation Procedures

    26 electric wiring note: electric wiring must be done by qualified person. Use copper wire only, the parameter of connecting cable is h07rn-f 4g 0.75mm 2 . Wiring of indoor unit insert the cable from outside the wall hole where piping already exist. Pull it out from front. Loosen terminal screws and...

  • Page 29: Others

    27 others 2.Installation inspection and test run: please operate unit according to this manual. Items to be checked during test run. Please made a " "in " " are there any gas leakage? How is insulation at piping connection carried out? Are electric wires of indoor and outdoor unit firmly inserted in...