Holman CCOF-4 Installation And Operation Instructions Manual - page 6
6
INSTALLATION
LOCATION
Do not install the Holman Counter top Convection Oven directly on the Floor. Holman/Star
Manufacturing has stands available to accommodate your new oven.
DO NOT install oven closer than 1" on the control side, from another oven.
DO NOT install oven closer than 12" on the control side, from a uncontrolled heat source
(char broiler, open flame, griddle, etc.), unless a Hi-Temperature Spacer is installed then
it can be reduced to 1".
ELECTRICAL
The ovens are equipped for the voltage indicated on the nameplate mounted on the lower right
side panel of the oven. They will operate on alternating current (AC) only. A cord & plug is provided
installed.
All electrical connections must be made by a licensed electrician and in accordance with local codes
or in the absence of local codes with NFPA No. 70 latest edition (in Canada use: CSA STD. C22.1)
DO NOT CONNECT TO DIRECT CURRENT (DC).
DO NOT CONNECT TO ANY OTHER TYPE OF CURRENT THAT IS OTHERWISE SPECIFIED
FOR THIS SPECIFIC UNIT, OR MACHINE WILL BE SERIOUSLY DAMAGED.
AIR SUPPLY
Make certain not to obstruct the flow of combustion (gas) and ventilation air. Provisions for adequate
air supply must be furnished.
LEVELING THE UNIT
This Holman Oven comes with legs installed at the factory, proper leveling is essential to receive a
proper baking performance. Level unit by adjusting the (4) feet which have an adjustment of -3/4”
(43.75mm) for accurate leveling.
WATER CONNECTION
CCOF-4 UNIT ONLY
It is vital that the water supply line be thoroughly flushed with clean water before being connected to
the oven’s water manifold.
Note the reading on the water pressure regulator gauge (not provided),
should read 20-25 PSI. If it reads more of less, adjust regulator until it falls into the proper
range.
Connect water supply to 3/8” female quick disconnect fitting located at right rear corner of the oven.
(3/8” female quick disconnect fitting accepts a 1/4” male quick disconnect coupler) Once the water
manifold and water supply are connected to the oven turn the oven ON and press the -shot steam
button for 30 seconds to remove the air and any impurities from the system.
WATER QUALITY REQUIREMENTS
Model CCOF-4 has a steam injection system, to ensure your new equipment works at it premium
performance, we recommend that in areas where hard water is present, a water softener is used.
Contact your local water equipment system provider to assist you in determining your specific water
quality, or contact Star Technical support for assistance, 1-800-807-9054.
WARNING
CAUTION