I WARM 760 Operation Manual

Summary of 760

  • Page 1

    Maj : 16.09.11 1 thermostat i warm 760 operation manual content important information for safe usage 1 introduction 1 function 2 controls and display 2 buttons 2 start-up of the thermostat 2 menu structure of the thermostat 2 basic settings 3 set the language 3 set the date and the time 3 daily prog...

  • Page 2

    Maj : 16.09.11 2 function the i-warm 760© is designed for the control of electrical underfloor heating systems (heating mats or cable units) or other electrical indoor heating systems. It automatically maintains a specified temperature exactly when you need it. There is no need to think about your h...

  • Page 3

    Maj : 16.09.11 3 to select a parameter, press the menu button. Basic settings the following chapters will present the basic setting options. You can choose between manifold options. The settings will enable you to adjust your heating system to your requirements and to operate the heating system ener...

  • Page 4

    Maj : 16.09.11 4 the displays animation confirms the settings made and the indicator will go back to the menu. Using the up and the down arrow buttons to choose the subdivision save settings and exit and press the menu button. The device now runs in its operating mode. This operating mode is intende...

  • Page 5

    Maj : 16.09.11 5 press the menu button to set this time interval as a comfort period . Keep on pressing the selection button and the menu button to extend the comfort period to the time interval 22:00-22:30. Keep on pressing the selection button until you reach the time interval 23:30–24:00 while le...

  • Page 6

    Maj : 16.09.11 6 set a heating program, according to your set of comfort periods, planned for weekends as described in the previous section daily program mode, then you will see the message if the heating program should be copied to sunday. Set a heating program, according to your set of comfort per...

  • Page 7

    Maj : 16.09.11 7 the window for choosing the type of indication, in the device's operating mode, appears. The following types of indication are available: a) «clock» — displays the current daytime in large figures b) «thermometer» — displays the current roomtemeprature c) «none» — the main indicatio...

  • Page 8

    Maj : 16.09.11 8 installation of floor-mounting temperature sensor the floor temperature sensor is installed when you perform your heating element (mat or cable section) installation. The sensor is connected to the thermostat via a junction box. Place the sensor in the corrugated plastic tube near i...

  • Page 9

    Maj : 16.09.11 9 technical data supply voltage 240 v ac , 50/60 hz maximum load current 16a consuming power 0,45w weight 150 g dimensions 80 × 80 × 52 mm time of setting storage when supply is disconnected 12 month ingress protection ip20 floor mounting temperature sensor ntc 6,8 k? Length of sensor...