IBC Water AFM20-180 Installation And Operating Instruction - Operating Principle
Page 2
General
Our AF Series Filters are fully automatic incorporating Backwash, Rinse-Pause, Fast Rinse
and Service Cycles, controlled by cam switches in the timer. Frequency of Backwashing can
be altered from that suggested in the Commissioning Section, if actual site conditions
dictate alterations.
Water enters the unit through the multi-port valve and passes through the media,
underdrain gravel and the distributor leaving through the multi-port valve.
Multi-Media Filters
Remove filterable turbidity at high flow rates several times the flow rate of conventional
filters, producing clear filtered water down to 10 micron through the stratified bed without
chemical flocculation. No additional pumping is necessary for Backwashing, as the
Backwash water required is normally only 80-90% of the service flow rate. Multi Media Filter
capacity is many times that of conventional filtration due to utilisation of the entire stratified
bed, resulting in low operating costs.
This unit is not designed to remove colloidal matter, a plant capable of coagulation is
required in such cases.
Operating Parameters
Water Temperature
5ºC - 48ºC
Water pH
5.5 - 9.0
Water Pressure
205 - 690 kPa
Oil
Free of Hydrocarbons
AF SERIES FILTERS
Table 2
OPERATING PRINCIPLE
TYPE
MODEL
CONTINUOS
FLOW RATE
L.P.M
PEAK FLOW
RATE L.P.M
BACKWASH
FLOW RATE
L.P.M
VALVE
APPROX.
WEIGHT
KG
OPERATING
PROCEDURES
Multi-
Media
AFM
20-180
120
160
114
180
320
Water Temp: 5ºC - 48ºC
Water pH: 5.5 - 9.0
Suspended Solids:
Max 100 mg/l
(Refer factory)
Iron: No Effect
Oil: Free of
Hydrocarbons
NOTE: Not recommended
for Colloidal Sediment
removal
Valve
180
Inlet
(mm)
40
Outlet
(mm)
40
Drain
(mm)
40
Operating Pressure: 205 - 690 kPa
Temperature: 5
º
C - 48
º
C Electrical: 240V 50Hz 3 watts maximum
Warning: A pressure reduction valve should be installed if water pressure is greater than 600kPa.
Warning: A pressure reduction valve should be installed if water hammer prevails.
Table at left shows recommended MINIMUM plumbing sizes.
FAILURE TO OBSERVE WARNING WILL VOID WARRANTY