IBC Water AFM20-180 Installation And Operating Instruction - page 8
Page 8
SET TIMER
Determine a regeneration schedule for the
conditioner and adjust the automatic timer as follows
(Reference Figures 7 and 8):
1. Pull all SKIPPER PINS out (away from control).
2. Rotate SKIPPER WHEEL until DAY ARROW
points to day of week or number 1.
3. Depress SKIPPER Pin(S) for day(s)
regeneration is required.
4. Pull TIMER KNOB out (away from timer face)
and rotate until BLACK ARROW on tripper arm
points to correct time of day on face plate.
5. Timer will automatically initiate regeneration on
preset days at 2:30AM. To alter time, simply
reset TIMER KNOB to an earlier or later time,
which will change the time of regeneration by
the same number of hours. (Time indicated as
BLACK ARROW will no longer be correct).
Each additional pin either pulled out or pushed in
equals 3 minutes
SET BACKWASH TIMING
Pull pins as shown for desired backwash time.
- See chart.
SET PAUSE TIME
Depress pins as shown for desired time.
- See chart. (Minimum of two pins down)
SET FAST RINSE TIME
Pull pins as shown for desired fast rinse time.
- See chart
BACKWASH CYCLE TIME INSTRUCTIONS
BACKWASH OR
FAST RINSE
PAUSE
NO. OF
PINS
OUT
TIME
NO. OF
PINS IN
TIME
1
8min.
2
1.5 min.
2
11 min.
3
4.5 min.
3
14 min.
4
7.5 min.
4
17 min.
5
10.5 min.
5
20 min.
6
13.5 min.
6
23 min.
7
16.5 min.
7
26 min.
8
19.5 min.
8
29 min.
9
22.5 min.
9
32 min.
10
25.5 min.
10
35 min.
11
28.5 min.
11
38 min.
12
31.5 min.
12
41 min.
13
34.5 min.
13
44 min.
14
37.5 min.
14
47 min.
15
40.5 min.
15
50 min.
16
43.5 min.
PIN TIME CHART
Figure 7