IBM Asia Pacific Hardware Announcement AG12-0014
IBM is a registered trademark of International Business Machines Corporation
12
– 6.1 bels (idling)
– 6.1 bels (operating)
Note: The noise emission level stated is the declared (upper limit) sound power
level, in bels, for a random sample of machines. All measurements made in
accordance with ISO 7779 and reported in conformance with ISO 9296.
System x3620 M3 servers are intended for use as rack-drawer servers and are
tested and designed to operate in a horizontal position.
Standards
These systems support or comply with the following standards:
• Multi Processor Specification (MPS) 1.4
• Peripheral Component Interconnect (PCI) specification 2.3
• Hardware-enabled to meet the International Organization for Standardization
(ISO) 9241, Part 3
Equipment approvals and safety
• Japan VCCI, Class A
• Australia/New Zealand AS/NZS CISPR 22:2009, Class A
• IEC-60950-1 (CB Certificate and CB Test Report)
• Taiwan BSMI CNS 13438, Class A); CNS 14336
• China CCC (China GB 4943-2001, GB 9254-2008 Class A, GB 17625.1:2003)
• Korea KN22, Class A; KN24
Operating environment
Air temperature:
• Server on:
– 10° C to 35° C (50° F to 95° F); altitude: 0 to 915 m (3,000 ft)
– 10° C to 32° C (50° F to 90° F); altitude: 915 to 2134 m (3,000 to 7,000 ft)
– 10° C to 28° C (50° F to 83° F); altitude: 2134 to 3050 m (7,000 to 10,000 ft)
• Server off: 5° C to 45° C (41° F to 113° F)
• Shipment: -40° C to +60° C (-40° F to 140° F)
Humidity:
• Server on: 20% to 80%, Max Dew Point 21° C, Max rate of change 5° C/hr
• Server off: 8% to 80%, Max Dew Point 27° C
• Shipment: 5% to 100%
Japan energy saving standard
Energy value tables - X3620 M3
Energy
Machine Category Power (Watts) CTP Consumption Input (Hz)
Type/Model 2005/2007 Consumption MTOPS Efficiency Frequency
737646x F/C 219 153486 0.001427 60
Hardware requirements
For attended installation of an operating system, this server requires a compatible:
• USB keyboard
• USB mouse
• HDD