IBM xSeries 346 User Manual

Manual is about: Types 8840 and 1880

Summary of xSeries 346

  • Page 1

    Ibm xseries 346 type 8840 user’s guide sc25-r347-40 e rserver.

  • Page 3

    Ibm xseries 346 type 8840 user’s guide sc25-r347-40 erserver.

  • Page 4

    Note: before using this information and the product it supports, read the general information in appendix b, “notices,” on page 39. Third edition (september 2004) © copyright international business machines corporation 2004. All rights reserved. Us government users restricted rights – use, duplicati...

  • Page 5: Contents

    Contents safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . V chapter 1. Introducing the ibm xseries 346 type 8840 . . . . . . . . . 1 related documentation . . . . . . . . . . . . . . . . . . . . . . 1 notices and statements used in this document . . . . . . . . . . . . . . 2 features a...

  • Page 6

    Using the documentation . . . . . . . . . . . . . . . . . . . . . 37 getting help and information from the world wide web . . . . . . . . . . 38 software service and support . . . . . . . . . . . . . . . . . . . 38 hardware service and support . . . . . . . . . . . . . . . . . . . 38 appendix b. Not...

  • Page 7: Safety

    Safety before installing this product, read the safety information. Antes de instalar este produto, leia as informações de segurança. Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí. Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit produc...

  • Page 8

    Läs säkerhetsinformationen innan du installerar den här produkten. Important: all caution and danger statements in this documentation begin with a number. This number is used to cross reference an english caution or danger statement with translated versions of the caution or danger statement in the ...

  • Page 9

    Statement 2 caution: when replacing the lithium battery, use only ibm part number 33f8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery cont...

  • Page 10

    Statement 4 ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb) caution: use safe practices when lifting. Statement 5 caution: the power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have ...

  • Page 11

    Statement 12 caution: the following label indicates a hot surface nearby. Statement 13 danger: overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed the branch circu...

  • Page 12

    Statement 16 caution: some accessory or option board outputs exceed class 2 or limited power source limits and must be installed with appropriate interconnecting cabling in accordance with the national electric code. Statement 17 caution: the following label indicates moving parts nearby. Warning: h...

  • Page 13: Chapter

    Chapter 1. Introducing the ibm xseries 346 type 8840 the ibm ® eserver ™ xseries ® 346 type 8840 server is a 2-u 1 -high server that can be upgraded to a symmetric multiprocessing (smp) server through a microprocessor upgrade. Performance, ease of use, reliability, and expansion capabilities were ke...

  • Page 14

    Depending on the server model, additional documentation might be included on the ibm xseries documentation cd. The server might have features that are not described in the documentation that you received with the server. The documentation might be updated occasionally to include information about th...

  • Page 15

    Features and specifications the following information is a summary of the features and specifications of the server. Depending on the server model, some features might not be available, or some specifications might not apply. Racks are marked in vertical increments of 1.75 inches. Each increment is ...

  • Page 16

    What your server offers the server uses the following features and technologies: v baseboard management controller the baseboard management controller provides environmental monitoring for the server. If environmental conditions exceed thresholds or if system components fail, the baseboard managemen...

  • Page 17

    V light path diagnostics light path diagnostics provides leds to help you diagnose problems. For more information, see the section about light path diagnostics in the installation guide. V redundant connection the addition of an optional network interface card (nic) provides a failover capability to...

  • Page 18

    V parity checking on the small computer system interface (scsi) bus and pci buses v power management: compliance with advanced configuration and power interface (acpi) v power-on self-test (post) v predictive failure analysis ® (pfa) alerts v redundant ethernet capabilities with failover support v r...

  • Page 19

    V reduced downtime v increased productivity of it personnel and users v reduced service and support costs for more information about ibm director, see the ibm director cd that comes with the server, the ibm director documentation on the cd, and the ibm xseries systems management web page at http://w...

  • Page 20

    Information panel. Usb connector system-error led information led system-locator led scsi activity led power-control button power-on led release latch the following controls, leds, and connectors are on the operator information panel: v release latch: slide this latch to the left to access the light...

  • Page 21

    Tx/rx tx/rx link link ethernet 2 ethernet 1 mouse universal serial bus (usb) serial video keyboard remote supervisor adapter ii ethernet slimline asm scsi system-locator led ethernet link status leds ethernet activity leds power cords ac power led dc power led ethernet link status leds: when these l...

  • Page 22

    System-locator led: use this led to visually locate the server among other servers. You can use ibm director to light this led remotely. Usb connectors: connect usb devices to these connectors. Video connector: connect a monitor to this connector. Mouse connector: connect a mouse or other ps/2 ® dev...

  • Page 23

    Statement 5 caution: the power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are d...

  • Page 24

    12 ibm xseries 346 type 8840: user’s guide.

  • Page 25: Chapter

    Chapter 2. Configuring the server the following configuration programs and capabilities come with your server: v configuration/setup utility the configuration/setup utility program is part of the basic input/output system (bios) code in your server. Use it to configure serial port assignments, chang...

  • Page 26

    V set and change settings for advanced hardware features v view and clear error logs starting the configuration/setup utility program complete the following steps to start the configuration/setup utility program: 1. Turn on the server. 2. When the prompt press f1 for configuration/setup appears, pre...

  • Page 27

    This choice is on the full configuration/setup utility menu only. V system security select this choice to set passwords. See “passwords” on page 17 for more information about passwords. This choice is on the full configuration/setup utility menu only. – power-on password select this choice to set or...

  • Page 28

    Manually enable the memory connectors. Use the arrow keys to highlight the pair of memory connectors that you want to enable, and use the arrow keys to select enable. Select memory configuration to enable memory mirroring or online-spare memory. You can enable either online-spare memory or memory mi...

  • Page 29

    Passwords from the system security choice, you can set, change, and delete a power-on password and an administrator password. The system security choice is on the full configuration/setup menu only. If you set only a power-on password, you must type the power-on password to complete the system start...

  • Page 30

    Administrator password if an administrator password is set, you must type the administrator password for access to the full configuration/setup utility menu. You can use any combination of up to seven characters (a–z, a–z, and 0–9) for the password. The administrator password choice is on the config...

  • Page 31

    V detects the scsi raid adapter, controller, or integrated scsi controller with raid capabilities and runs the scsi raid configuration program (with lsi chip sets for serveraid adapters only) v checks the microcode (firmware) levels of a serveraid adapter and determines whether a later level is avai...

  • Page 32

    Installing your operating system without serverguide if you have already configured the server hardware and you decide not to use the serverguide program to install your operating system, complete the following steps to download the latest operating-system installation instructions from the ibm supp...

  • Page 33

    Configuring the controller complete the following steps to use the scsi hostraid feature to configure a raid level-1 array: 1. From the scsiselect utility main menu, select configure/view hostraid settings. 2. From the list of ready drives, type c to create an array. 3. Select raid-1 when asked to s...

  • Page 34

    Using the baseboard management controller the baseboard management controller provides environmental monitoring for the server. If environmental conditions exceed thresholds or if system components fail, the baseboard management controller lights leds to help you diagnose the problem and also record...

  • Page 35

    V remote console com port: com 1 v remote console baud rate: 19200 v remote console data bits: 8 v remote console parity: none v remote console stop bits: 1 v remote console text emulation: ansi v remote console keyboard emulation: ansi v remote console active after boot: enabled v remote console fl...

  • Page 36

    7:2345:respawn:/sbin/agetty -h ttys0 19200 vt102 2. Add the following line at the bottom of the /etc/securetty file to enable a user to log in as the root user through the sol console: ttys1 lilo configuration: if you are using lilo, complete the following steps: 1. Complete the following steps to m...

  • Page 37

    Original /etc/lilo.Conf contents prompt timeout=50 default=linux boot=/dev/hda map=/boot/map install=/boot/boot.B message=/boot/message linear image=/boot/vmlinuz-2.4.9-e.12smp label=linux initrd=/boot/initrd-2.4.9-e.12smp.Img read-only root=/dev/hda6 image=/boot/vmlinuz-2.4.9-e.12 label=linux-up in...

  • Page 38

    Modified /etc/lilo.Conf contents prompt timeout=50 default=linux-monitor boot=/dev/hda #map=/boot/map install=/boot/boot.B #message=/boot/message linear # this will allow you to only monitor the os boot via sol image=/boot/vmlinuz-2.4.9-e.12smp label=linux-monitor initrd=/boot/initrd-2.4.9-e.12smp.I...

  • Page 39

    Kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 console=tty1 console=ttys0,19200 initrd /initrd-2.4.9-e.12smp.Img note: the entry that begins with kernel /vmlinuz is shown with a line break after console=tty1 . In your file, the entire entry must all be on one line. The following examples show the o...

  • Page 40

    Modified /boot/grub/grub.Conf contents #grub.Conf generated by anaconda # # note that you do not have to rerun grub after making changes to this file # notice: you have a /boot partition. This means that # all kernel and initrd paths are relative to /boot/, eg. # root (hd0,0) # kernel /vmlinuz-versi...

  • Page 41

    A. Comment out the gfxmenu line by adding a # in front of the word gfxmenu . B. Add the following line before the first title line: # this will allow you to only monitor the os boot via sol c. Append the following text to the first title line: sol monitor d. Append the following text to the kernel l...

  • Page 42

    Modified /boot/grub/menu.Lst contents notes root chainloader +1 title failsafe kernel (hd0,1)/boot/vmlinuz.Shipped root=/dev/hda2 ide=nodma apm=off vga=normal nosmp 1 disableapic maxcpus=0 3 initrd (hd0,1)/boot/initrd.Shipped note 1: the kernel line is shown with a line break. In your file, the enti...

  • Page 43

    Original bootcfg program output boot loader settings ---------------------------- timeout: 30 default: multi(0)disk(0)rdisk(0)partition(1)\windows boot entries ---------------- boot entry id: 1 os friendly name: windows server 2003, standard path: multi(0)disk(0)rdisk(0)partition(1)\windows os load ...

  • Page 44

    Opens. 3. Follow the prompts to complete the installation. The installation program prompts you for a tcp/ip port number and an ip address. Specify an ip address, if you want to limit the connection requests that will be accepted by the utility program. To accept connections from any server, type in...

  • Page 45

    The utility starts automatically when the server is started. You can also locate the /ect/init.D directory to start the utility and use the following commands to manage the utility: smbridge status smbridge start smbridge stop smbridge restart using the baseboard management controller utility progra...

  • Page 46

    Use the following commands in cli mode: – identify control the system-locator led on the front of the server. – power turn the server on and off remotely. – sel perform operations with the system event/error log. – sysinfo display general system information that is related to the server and the base...

  • Page 47

    5. Use the arrow keys to select a choice from the menu. 6. Follow the instructions on the screen to change the settings of the selected items, and press enter. Scsiselect utility menu choices the following choices are on the scsiselect utility menu: v configure/view scsi controller settings select t...

  • Page 48

    36 ibm xseries 346 type 8840: user’s guide.

  • Page 49: Appendix

    Appendix a. Getting help and technical assistance if you need help, service, or technical assistance or just want more information about ibm products, you will find a wide variety of sources available from ibm to assist you. This appendix contains information about where to go for additional informa...

  • Page 50

    Getting help and information from the world wide web on the world wide web, the ibm web site has up-to-date information about ibm xseries and intellistation products, services, and support. The address for ibm xseries information is http://www.Ibm.Com/eserver/xseries/. The address for ibm intellista...

  • Page 51: Appendix

    Appendix b. Notices this information was developed for products and services offered in the u.S.A. Ibm may not offer the products, services, or features discussed in this document in other countries. Consult your local ibm representative for information on the products and services currently availab...

  • Page 52

    Trademarks the following terms are trademarks of international business machines corporation in the united states, other countries, or both: active memory predictive failure analysis active pci ps/2 active pci-x serveraid alert on lan serverguide bladecenter serverproven c2t interconnect techconnect...

  • Page 53

    Cd-rom drive speeds list the variable read rate. Actual speeds vary and are often less than the maximum possible. When referring to processor storage, real and virtual storage, or channel volume, kb stands for approximately 1000 bytes, mb stands for approximately 1 000 000 bytes, and gb stands for a...

  • Page 54

    In the netherlands, the following applies. Electronic emission notices federal communications commission (fcc) statement note: this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide r...

  • Page 55

    European union emc directive conformance statement this product is in conformity with the protection requirements of eu council directive 89/336/eec on the approximation of the laws of the member states relating to electromagnetic compatibility. Ibm cannot accept responsibility for any failure to sa...

  • Page 56

    Power cords for your safety, ibm provides a power cord with a grounded attachment plug to use with this ibm product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet. Ibm power cords used in the united states and canada are listed by underwriter’s laborat...

  • Page 57

    Ibm power cord part number used in these countries and regions 14f0033 abu dhabi, bahrain, botswana, brunei darussalam, channel islands, china (hong kong s.A.R.), cyprus, dominica, gambia, ghana, grenada, iraq, ireland, jordan, kenya, kuwait, liberia, malawi, malaysia, malta, myanmar (burma), nigeri...

  • Page 58

    46 ibm xseries 346 type 8840: user’s guide.

  • Page 59: Index

    Index a ac power led 9 acoustical noise emissions 3 active memory 4 attention notices 2 availability 5 b baseboard management controller 4 baseboard management controller utility programs 33 c caution statements 2 class a electronic emission notice 42 command-line interface commands identify 34 powe...

  • Page 60

    Notices electronic emission 42 fcc, class a 42 notices and statements 2 o online publications 2 operator information panel 7 osa smbridge management utility program enabling and configuring 22 installing 31 p pci expansion slots 3 power cords 44 power supply specifications 3 power-control button 8 p...

  • Page 62