ICharger 4010DUO User Manual - page 13
iCharger
iCharger
iCharger
iCharger Synchronous
Synchronous
Synchronous
Synchronous Balance
Balance
Balance
Balance Charger/Discharger
Charger/Discharger
Charger/Discharger
Charger/Discharger
4010DUO
4010DUO
4010DUO
4010DUO
- 13 -
① LiXX
LiXX
LiXX
LiXX Battery
Battery
Battery
Battery Charge
Charge
Charge
Charge Setup
Setup
Setup
Setup
Select
Program→Charge to enter Charge setup interface.
Note: 1.The charger first charges with constant current (CC) according to the user setting then turns
to constant voltage (CV) when the charging voltage reaches the peak point. In the CV phase
the current gradually falls, and the charger will terminate charging when the current falls
below than percent of the configured charge current.
2.Charge mode has
Balance, Not Balance two modes available, when choose Balance mode,
balance board must be connected except for connecting 1S battery. The balance charge
mode is for balancing the voltage of battery cells while charging. In this mode the battery
balance lead must be connected to the balance port, and the charger can monitor the
voltage of individual cells and adjust the input current fed into each cell to normalize the
voltage.
3.Tick
Show
Show
Show
Show to display this program on MEMORY SETUP, and the built-in program is ticked by
default.
4. When the value of charge cells voltage exceeds the recommended value (LiPo 4.2V, LiIo 4.1V,
LiFe 3.6V), there will alarm and beep tones
.
As long as the users change the value, the main
charging interface, "battery types" and "cells voltage" setting value will displayed alternately.
Switch to
Balance mode on Chg Mode to active "
" button and click to enter
Balance mode setup interface.
Switch to
User mode on Balance Speed to active Balance Diff, Balance Set Point, Balance Over Charge, Balance
Done Delay setting, after setting click"
" to return to the previous interface.
LiXX Battery Charge Program Setup
Chg Current:
0.05A-40A; default:2A
Chg Mode:
Balance (default), Not Balance
Chg End Current:
1%-50%; default: 10%
Chg Cell Volt:
3.85V/Cell-4.35V/Cell;
Default: 4.2V/Cell
LiXX Battery Balance Setup
Balance Start:
CV, CV-0.1V--1V, Always
Default: CV-0.2V
Balance Speed:
User, Fast,
Normal(default), Slow
LiXX Battery Charge Balance Setup
Balance Diff:
1mV-10mV; default: 5mV
Balance Set Point:
1mV-50mV; default: 5mV
Balance Over Charge:
0mV-10mV; default: 0mV
Balance Done Delay:
0Min-20Min; default: 1Min