Icom CY 5000 Instruction Manual

Summary of CY 5000

  • Page 1

    Instruction manual vhf fm repeater cy 5000 uhf fm repeater cy 6000

  • Page 2

    Important read this instruction manual carefully before attempting to operate the repeater. Save this instruction manual– this manual contains important safety and operating instructions for the cy fr series. Explicit definitions word definition warning personal injury, fire hazard or electric shock...

  • Page 3

    Forward thank you for purchasing this icom america systems cy fr vhf/uhf repeater. With proper care, this product should provide you years of trouble-free operation. Features ❍ automatic battery backup and charging system a built-in backup system supports automatic switching to an external battery (...

  • Page 4: Panel Description

    ➊ microphone/speaker connector [mic/sp] this 8-pin modular jack accepts the optional field service aid. ➀ ➇ 1 panel description ■ front panel 1 ➀ +8 v dc output (max. 15 ma) ➁ output port for pc programming ➂ afo ➃ m ptt (input port for tx control) ➄ microphone ground ➅ microphone input ➆ ground ➇ i...

  • Page 5

    ➊ lighted power switch [power] toggles to turn the repeater ac power on or off. Located on the back panel of the repeater. Note: does not effect dc power input. ➋ transmit antenna connector [tx/ tx•rx] ➥ connects a transmit antenna (impedance: 50 Ω ) and outputs transmit signals. ➥ when an optional ...

  • Page 6

    Pin no. Pin name description specification 1 cfs chassis fan sensor — 2 txd output terminal for serial communication data. — 3 rxd input terminal for serial communication data. — 4 rts output terminal for request-to-send data. — 5 cts input terminal for clear-to-send data. — 6 nc no connection — 7 g...

  • Page 7: Installation and Connections

    2 installation and connections ■ unpacking after unpacking, immediately report any damage to the delivering carrier or dealer. Keep the shipping cartons. For a description and a diagram of accessory equipment included with the cy fr series, see ‘supplied accessories’ of this manual. ■ selecting a lo...

  • Page 8: Required Connections

    ■ required connections installation and connections 2 [dc power input terminal] make sure the back up battery is correctly connected. Use a cable with following current capacity. Solder or clamp the cable plug when connecting the power cable to the backup battery to prevent voltage drops. Power cabl...

  • Page 9: Power

    Make sure the ac [power] switch is turned off when connecting an ac power cable or a backup battery (emergency power supply). The cy fr series can operate with either an ac or dc input. If ac power is interrupted and there is an external dc source (emergency power supply), the repeater will continue...

  • Page 10: Optional Unit Installation

    3 optional unit installation ■ opening the repeater’s case follow the case and cover opening procedures shown here when an optional unit is installed or adjust the internal units, etc. Caution: disconnect the ac power cable and/or dc power cable from the repeater. Otherwise, there is danger of elect...

  • Page 11: Operation

    4 operation ■ turning power on ➀ on rear panel, toggle ac power switch up to turn ac power on. ■ receiving and transmitting receiving ➀ connect optional field service aid microphone/speaker. •when receiving a signal, rx indicator turns on and audio is emitted from the speaker. Transmitting for local...

  • Page 12: Maintenance

    5 maintenance ■ fuse replacement if a fuse blows or the repeater stops functioning, try to find the source of the problem, and replace the damaged fuse with a new, rated fuse. 9 caution : disconnect the dc power cable from the repeater. Otherwise, there is a danger of electric shock and/or equipment...

  • Page 13: Specifications and Options

    6 specifications and options ■ specifications ◆ ur-fr5000 general power supply 105-130 vac 50/60 hz 5a max requirement (nominal) 185-250 vac 50/60 hz 13.6 vdc (nominal) 16.2 amp max dimensions (projections 480 (w) x 133 (h) x 364 (d) mm; not included) 18.90 (w) x 524 (h) x 14.33 (d) in. Weight: 8.6 ...

  • Page 14: Options

    11 ■ options • field service aid microphone speaker • hm-152 hand microphone • hm-152t dtmf microphone hand microphone with a dtmf keypad • sm-25 desktop microphone • sp-22 speaker • ias vhf dup kit vhf duplexer kit with rf jumpers • ias uhf dup kit uhf duplexer kit with rf jumpers • 220v ac power c...

  • Page 15

    Memo.

  • Page 16

    Count on us! 10084 11/09 ©2009 icom america inc. The icom logo is a registered trademark of icom inc. All specifications and information is subject to change without notice or obligation. All other trademarks remain the property of their respective owners..