Icom IC-FR5100 Series Handbook - page 33
Scan
33
• Talk back timer is set in Talk Back (Sec) in the
Scan Setting screen.
¾ Text
Select the text indication capability from OFF, Text or
Start CH during scan.
Disable
The secondary channel is not used.
Prio-A CH
The priority A channel is used as the
secondary channel.
Prio-B CH
The priority B channel is used as the
secondary channel.
Start CH
Scan start channel is used as the
secondary channel.
CH Number
Select
The selected channel is used as the
secondary channel.
¾Secondary CH
(Available when "Priority Scan" is
selected in Scan Type.)
Select the desired channel as a secondary channel.
The selected channel is monitored during priority scan.
The secondary channel is lower priority than the
primary channel.
Last CH
Transmission is performed in the last
busy channel. If thee is no busy
channel, the scan start channel is
selected for transmission.
Prio-A CH
Transmission is performed on the
priority A channel.
Prio-B CH
Transmission is performed on the
priority B channel.
Start CH
Transmission is performed on the scan
start channel.
CH Number
Select
Transmission is performed on the
selected channel.
¾TX CH
(Available when "Normal Scan" or "Priority
Scan" is selected in Scan Type.)
Select the desired channel as a transmission channel.
¾ Talk Back
(Available when "Normal Scan" or
"Priority Scan" is selected in Scan Type.)
Select the talk back function ON or OFF.
If "Last CH" is selected in TX CH, this function is not
available.
ON
When transmission is performed within the
talk back timer time* (after the resume
timer has passed), the signal is transmitted
on the last busy channel.
OFF
Even if transmission is performed within
the talk back timer time* (after the resume
timer has passed), the signal is transmitted
on the channel that is selected in TX CH.
Cancel
Scan
Scan is canceled and transmission is
performed on the channel that is
selected in TX CH.
If Talk Back is turned ON and
transmission is performed within the
talk back timer time, the signal is
transmitted on the last busy channel.
Pause
Scan
Scan is paused until the signal
disappears and then resumes after the
resume timer time* has passed.
¾TX Action
(Available when "Normal Scan" or
"Priority Scan" is selected in Scan Type.)
Select the scan condition when transmission is
performed during scanning.
* Resume timer is set in Resume (Sec) in Scan
Setting screen.
¾
Cancel CH (Available when "Normal Scan" or
"Priority Scan" is selected in Scan Type.)
Select the desired channel type that is selected
when scan is cancelled (except for transmission.)
Start CH
The scan start channel is selected
automatically.
Start
CH/Talk
Back
The scan start channel is selected
automatically when scan is canceled
during scanning.
The last busy channel is selected
automatically when scan is canceled while
receiving a signal, or during scanning
within the talk back timer time (after the
resume timer has passed).
TX CH
The channel that is selected in TX CH is
selected automatically.
TX
CH/Talk
Back
The channel that is selected in TX CH is
selected automatically when scan is
canceled during scanning.
The last busy channel is selected
automatically when scan is canceled while
receiving a signal, or during scanning
within the talk back timer time (after the
resume timer has passed).
OFF
The text indication is turned OFF.
Text
The text indication is turned ON. The
channel's text that is programmed in
Display Text
as above is indicated during
scan.
Start
CH
The text indication is turned ON. The scan
start channel's text is indicated during scan.