LEAK TESTING:
STEP 1
Mix a solution of liquid dish soap and water (or obtain profession leak detector liquid).
Turn on Gas.
STEP 2
Spray or brush detector liquid thoroughly on all fuel line connections (Fig. 7). If soap
bubbles are generated at any connection, tighten the fitting and re-test. If a leak is
detected that cannot be successfully repaired, immediately turn off the gas and
contact your dealer for further assistance.
LIGHTING INSTRUCTIONS:
1.
Turn the main gas supply ON.
2.
Depress the side burner control knob down slightly and turn SLOWLY counter clo
ck wise until the ‘click’ of
the igniter is heard. (This side burner has a built in ignition system).
3.
If the side burner does NOT light, turn the control knob to the OFF position and try again.
4.
Once the burner has lit, turn the control knob counter clock wise to the desired heat level.
NOTE: To turn the unit off, turn the gas control clockwise to the OFF position.
GAS CONVERSION: (Optional Orifice not included)
1. Remove the Cook Grid and Burner,
2. Remove the original O
rifice, using a ¼”
Socket Wrench, with an extension and
7mm socket (Fig. 8)
3. Lightly coat threads of the replacement Orifice
with Teflon Tape or Gas Fitting Dope.
4. Install the new Orifice into Side Burner (Fig. 9)
5.
Propane; Please ensure that the fuel source is regulated to 11” WC.
6.
Natural Gas; Please ensure that the fuel source is regulated to 4.5” WC.
TECH TIP
Do NOT over tighten orifice; threads
can easily be broken off!