    Ozonator o3 tb1 230 vac, 3-wire connection use copper conductors only. Wire size must be appropriate per nec and/or local codes 2 1 flow switch hi-limit/freeze sensor temperature sensor j2 j3 f1 20a 250v sc-20 circ. Pump main pump spa light transformer 230 vac j4 hi lo grn logic jumper settings all ...

  • Page 2: Attention New Spa Owner!

    Attention new spa owner! Congratulations on the purchase of your new jacuzzi® spa! The following is a list of automated functions performed by your spa. These functions are listed below in an attempt to suppress any operational concerns you may have during the first 24-hours of ownership! Also liste...

  • Page 3: Table Of Contents

    Table of contents 1.0 important spa owner information ..............................................1 2.0 fcc notice ....................................................................................1 3.0 important safety instructions .....................................................2 4.0 choo...

  • Page 4

    13.0 water quality maintenance .......................................................29 13.1 phcontrol....................................................................................29 13.2 sanitizing......................................................................................29 13.3 o...

  • Page 5: Herein.

    Page 1.0 important spa owner information your jacuzzi ® 200 series spa is constructed to the highest standards and is capable of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the spa for effi- cient operation, an uncovered spa surface di...

  • Page 6

    Page 2 3.0 important safety instructions read and follow all instructions carefully when installing and using this electrical equipment, basic safety precau- tions should always be followed, including: . Warning: to reduce the risk of injury, do not permit children to use this product unless they ar...

  • Page 7

    Page 3 8. Warning: to reduce the risk of injury: 9. The water in the spa should never exceed 04°f (40°c). Water temperatures between 00°f (38°c) and 04°f (40°c) are consid- ered safe for a healthy adult. Lower water temperatures are recom- mended for young children and when spa use may exceed 0 min-...

  • Page 8

    Page 4 important csa safety instructions (canada only) when using this electrical equipment, basic safety precautions should always be followed, including the following: . Read and follow all instructions. 2. A green colored terminal or a terminal marked g, gr, ground, grounding or the symbol* is lo...

  • Page 9: Save These Instructions

    Page 5 warning: water temperature in excess of 40°c (04°f) may be injuri- ous to your health. Warning: before entering the spa, measure the water temperature with an accurate thermometer. Warning: do not use a spa immediately following strenuous exercise. Warning: prolonged immersion in a spa may be...

  • Page 10: Ber #6530-082.

    Page 6 a warning sign is provided in your warranty packet. Please install it at a location near your spa, where it is visible to the user of the spa. For additional or replacement signs please contact your local jacuzzi spas dealer and reference item num- ber #6530-082. Cautions . Persons suffering ...

  • Page 11: 4.0 Choosing A Location

    Page 7 4.0 choosing a location important: because of the combined weight of the spa, water and users, it is extremely important that the base upon which the spa rests be smooth, flat, level and capable of uniformly supporting this weight, without shifting or settling, for the entire time the spa is ...

  • Page 12

    Page 8 it is in place. Proper support is critical especially if the spa is to rest on a second story or higher. For spas that are to rest on balconies, roofs or other platforms not specifically tied into the main structural support, you should consult a professional structural engineer with experien...

  • Page 13

    Page 9 5.0 general electrical safety instructions your new jacuzzi ® spa is equipped with a “state-of-the-art” equipment system. It contains the most advanced safety and self-protective equip- ment in the industry. Nonetheless, this spa must be installed properly to insure dependable usage. Please c...

  • Page 14: 240V/40A*

    Page 0 us/canada j-230 2-pump model (60hz) 240v/40a* 240v/50a** 240v/60a*** voltage: 240 vac 240 vac 240 vac # of wires: 3 3 3 frequency: 60hz 60hz 60hz current draw: 26a 36a 45a circuit breaker: 40a, 2-pole 50a, 2-pole 60a, 2-pole * in 40a configuration, the heater will not operate while either jet...

  • Page 15: Son!

    Page 7.0 electrical wiring instructions important notice: the electrical wiring of this spa must meet the requirements of the national electrical code/usa (nec) and any applicable state or local codes. The electrical circuit must be installed by a qualified electrician and approved by a local buildi...

  • Page 16: Do Not

    Page 2 dance with these instructions will void both the independent testing agency listing and the manufacturer’s warranty. 2. Dedicated 230-240v power models: this spa must be permanently connected (hard-wired) to the power supply. No plug-in connections or extension cords are to be used in conjunc...

  • Page 17

    Page 3 figure-b - control box . Terminal block 2. Bonding lug 3. Grounding terminal tb 3 2 7 8 3 6 2 2 figure-a equipment area . Control box 2. Power supply inlet(s) 3. 2-speed pump # 4. Heater 5. Pump drain plug flow note: pump locations vary by model 5 5 4 6. -speed pump #2 7. Optional cd ozonator...

  • Page 18: 2.   Fill Spa

    Page 4 8.0 spa fill up procedure for best results, read each step in its entirety before proceeding with that step: 1. Prepare the spa for filling • clear all debris from the spa. (although the spa shell has been polished at the factory, you may want to treat it with a specially for- mulated spa cle...

  • Page 19: 7.   Set Spa To Heat

    Page 5 4. Activate jets pump 1 depress the jets button on the control panel once to activate jets pump #. 5. Add start-up chemicals add the spa water chemicals as recommended by your authorized jacuzzi dealer. See section 3.0 “water quality maintenance” (page 29) for general guidance. 6. Establish a...

  • Page 20: Water Fill Volume By Model

    Page 6 will reduce the time required for heating, thereby minimizing operat- ing costs. • the time required for initial heat-up will vary depending on the start- ing water temperature. Danger: risk of injury, always check water temperature carefully before entering spa! Decontamination procedure (st...

  • Page 21

    Page 7 12. Fill spa until water covers all jets but does not touch the bottom of the lowest headrest. Do not overfill. Caution: never fill with water from a water softener. If your water is extremely “hard”, it is preferable to fill half-way with hard water and the rest of the way with softened wate...

  • Page 22: 9.0 Control Functions

    Page 8 9.0 control functions 9.1 control panel a. Led display: can display current water temperature (default dis- play), water temperature set point, selected filtra- tion/heating mode, and error messages. B. Warmer ( + ) button: increases water temperature set point. C. Cooler ( - ) button: decrea...

  • Page 23

    Page 9 9.2 spa features and controls 1 4 2 2 4 4 7 5 9 8 10 3 . Control panel 2. Air controls 3. Filter/skimmer 4. Therapy jets 5. Massage selector (j-220 only). J-20 models use a “diverter jet” which functions as a diverter in these models. See page 23 for details. 6. Therapy seats 7. Spa light 8. ...

  • Page 24: (J-210 & J-220 Models)

    Page 20 9.3 jet/air controls diagram (j-210 & j-220 models).

  • Page 25: (J-230 Models)

    Page 2 9.4 jet/air controls diagram (j-230 models).

  • Page 26: 10.2 Activate Pumps

    Page 22 10.0 operating instructions the spa control system has automatic functions that operate upon start- up and normal operation to protect the system. Upon power up, the readout displays the following information: . Control panel displays current software release (e.G. 5.55), then; 2. Control pa...

  • Page 27: 10.6 Air Controls

    Page 23 mode, then repeatedly press the button to turn the light off or to select one of 6 constant colors illustrated below. You must press the light button within 5 seconds between each “off” or “color” step in the light sequence to prevent it from resetting. Pressing the button after 5 seconds re...

  • Page 28: 11.3 Lock Modes (L1-L2)

    Page 24 11.0 automatic filtration cycles the control system activates a programmable “standard” or “economy” filtration cycle to remove debris from your spa. These cycles use the low speed pump, skimmer basket, and filter cartridge quickly clear “skim” the water of debris and minimize their “bathtub...

  • Page 29: Lock Modes (L1-L2)

    Page 25 economy filtration/heating modes (f4-f6) f4 4 hours of filtration/heating per day (one 2-hour cycle every 2 hours). F5 6 hours of filtration/heating per day (one 2-hour cycle every 8 hours). F6 8 hours of filtration/heating per day (one 2-hour cycle every 6 hours) lock modes (l1-l2) l1 lock ...

  • Page 30: To Drain Spa:

    Page 26 to accomplish this, follow these steps: 1. Turn off power to the spa at the home’s breaker panel or select the l1 “lock out” mode (page 24) to disable all spa functions. 2. Remove the filter strainer lid assembly. 3. Remove the filter cartridge by rotating it counterclockwise to unthread it ...

  • Page 31

    Page 27 cap and attach garden hose to drain hose fitting. 4. Lay drain hose down on ground, making sure water drains away from spa. After refilling, turn on power to the spa and follow the steps listed under the “spa fill up procedure” (page 4). 12.3 cleaning the spa interior to preserve the sheen o...

  • Page 32: 12.7 Winterizing

    Page 28 12.7 winterizing your jacuzzi spa is designed to automatically protect itself against freezing when operating properly. During periods of severe freezing temperatures, you should check periodically to be certain that the elec- trical supply to the spa has not been interrupted. In extreme, bi...

  • Page 33: 13.1 Ph Control

    Page 29 13.0 water quality maintenance maintaining the quality of the water within specified limits will serve to enhance your enjoyment and prolong the life of the spa’s equipment. It is a fairly simple task, but it requires regular attention because the water chemistry involved is a balance of sev...

  • Page 34: 14.1 Panel Displays Sn1

    Page 30 13.3 optional cd ozone water maintenance system if you have elected to have your spa equipped with the optional jacuzzi cd ozone water purification system you will find that your water stays fresh and clear with significantly less chemical sanitizer usage. You will also probably be able to g...

  • Page 35: 14.6 Panel Displays Ice

    Page 3 14.6 panel displays ice freeze protection - a potential freeze condition has been detected. No action is required. The pump and heater will operate to circulate and warm water through the plumbing until spa is out of danger. See “winterizing” (page 28). 14.7 panel displays oh water temperatur...

  • Page 36: 15.3 Poor Jet Action

    Page 32 refilled. Press the jets button several times, never leaving the motor on for more than 5 to 0 seconds at a time. Turn power off and let the air out by loosening the cap on the diverter valve (j-220 models only) and/or remove the filter. Refer to section 9.2 (page 9). Make certain you tighte...

  • Page 37

    Page 33 16.0 j-210/j-220 convertible circuit diagram (60hz) this wiring diagram is used for the j-20/j-220 us/canada 20/240 vac (60hz) convertible power models. Optional ozonator o3 standard 3-wire 120 vac connection (60 hz, 1 phase, 15a service) use copper conductors only. Wire size must be appropr...

  • Page 38

    Page 34 17.0 j-230 circuit diagram (60hz) this wiring diagram is used for all j-230 us/canada 240 vac (60hz) dedicated power models. O z o n a t o r ( o p t io n a l) o 3 grn tb1 standard 240 v ac, 3-wire connection (60hz, 1-phase service) use copper conduct ors onl y. Wire size must be appropria te...

  • Page 39

    Page 35 standard 3-wire 230 vac connection (50 hz, 1 phase service) use copper conductors only. Wire size must be appropriate per nec and/or local codes. Blk blk blu blu blu blu blu blu brn brn brn brn brn brn brn heater 2.7kw @ 230 vac pressure switch hi-limit/freeze sensor temperature sensor j2 j3...

  • Page 40

    Page 36 19.0 j-230 export circuit diagram (50hz) this wiring diagram is used for all j-230 export 230 vac (50hz) dedicated power models. Optional stereo and power supply on j-335, j-345 models only . Power supply o z o n a t o r ( o p t io n a l) o 3 grn tb1 230 v ac 3-wire connection (50hz, 1-phase...

  • Page 41: Notes

    Page 37 notes.

  • Page 42

    Page 38.

  • Page 44: 230 Vac, 3-Wire Connection

    Ozonator o3 tb1 230 vac, 3-wire connection use copper conductors only. Wire size must be appropriate per nec and/or local codes 2 1 flow switch hi-limit/freeze sensor temperature sensor j2 j3 f1 20a 250v sc-20 circ. Pump main pump spa light transformer 230 vac j4 hi lo grn logic jumper settings all ...