Jacuzzi Platinum Series Owner's Manual - Control Panel Operation
Control Panel Operation
Initial Start-Up
The spa will automatically begin to operate when elec-
trical power is applied. There is no ON/OFF switch for
the spa system.
The control system is designed so that by simply con-
necting the spa to its properly grounded power source
and pressing the mode button, the spa will function
properly and safely at 100
°
F. In this mode, all control
panel buttons are completely functional. To use the full
capabilities, it is important to set the time of day.
OPERATION
7
Press
. Time of day will be shown. Then press
. SET TIME message will be shown. Then
press
. SET START FILTER 1 message will
be shown. At this point, each time the program button is
pressed, the filter start time, the heater enable status,
and the filter stop time will be indicated on the display.
When the filter start or filter stop times are displayed,
press
or
to reset the times.
When the SET HEAT message is displayed, press
or
to set the center display to ON or
In the ON position, the spa will warm to the set tempera-
ture. In the OFF position, the heater, in the economy
mode, will not be activated.
Panel Lock
The panel lock is provided to prevent tampering with the
control panel. When the panel lock is engaged, all the
automatic spa functions will operate normally.
Press these buttons within 3 seconds to activate the
lock. When locked, the display will show the spa
temperature along with the lock symbol. All the panel
buttons are now deactivated except the program button,
which is used to initiate the unlock sequence.
Press
. The center display will read
LOC
.
Then
.
The center display will read
0
.
Then
.
The center display will read
.
Setting the Time of Day:
Press
then
then
or
.
After either button is pressed once, hours will advance
or decrease automatically in one-minute increments.
Press either
or
again to stop the
display's time-setting cycle.
Filter System Operation
The spa is continuously filtered for 24 hours a day. The
blower will activate for 30 seconds periodically to clean
out the air channel and the jet pumps will operate for 5
minutes periodically to circulate the water. The ozone
generator also operatescontinuously.
Note: The ozone generator will be disabled for 1
hour whenever the jet pump, blower, or light button
is pressed.
Changing Heating Cycles
If you wish to leave the heater OFF during the day, the
following procedure can be used to change the auto-
matic heater operation.
OFF.