Jadever JCL User Manual

Other manuals for JCL: Service Manual

Summary of JCL

  • Page 1

    Vetek weighing ab jcl 0 user manual counting scale jcl..

  • Page 2: Table of Contents

    Vetek weighing ab jcl 1 table of contents 1. Introduction ………………………………….……………………………………........ 1 2. Precautions ……………………………………….…………………………………….. 1 3. Before using the product 3- 1 unpacking and checking………………………………………………………………… 3-2 installing components. ………………………………………..…………………………. 3-3 leveling t h...

  • Page 3

    Vetek weighing ab jcl 2 1. Introduction thank you for deciding to purchase a jcl counting scale from jadever. This goods has the excellent performance and splendid properties under severe quality management. It is recommended to read this manual in full before using it for good function application....

  • Page 4

    Vetek weighing ab jcl 3 4. Product introduction 1) leveler 2) leveling foot 3) rs-232 interface 4) plastic weighing pan 5) stainless steel weighing pan 6) on/off switch 7) two-stage switch 8) power socket 9) transport protection screw 10) plug buckle 4-1 specifications& general features specificatio...

  • Page 5

    Vetek weighing ab jcl 3 general features · a/d covered by aluminium plate, prevent pcb from static and moisture · tare, preset tare, auto zero tracking · automatic counting accuracy improvement (acai) for enhanced counting accuracy · hi/ok/lo quantity checking function · stainless steel weighing pan...

  • Page 6: 0 ~9

    Vetek weighing ab jcl 4 5) leveler 6) hi lamp (on) indicating parameter item is selected when setting buzz sounds. (see 5. Function setting, setting buzz sounds) ok lamp (on) -- indicating parameter item or is selected when setting buzz sounds. Low lamp (on) —indicating parameter item is selected wh...

  • Page 7

    Vetek weighing ab jcl 5 2) ● key decimal point; toggles between upper limit and lower limit setting when hi-lo-ok function is enabled. (see 7-2-1) 1) print key outputs data when prt.Pr (print stably) is selected as the print mode. 2) zero key zeros the display (within 2% of max.Capacity) or cancels ...

  • Page 8

    Vetek weighing ab jcl 6 5. Operation here we take jcl-15k model as an example. 5-1 basic weighing 5-1-1 weighing place item to be weighed on the scale. The weight window shown is 2000g, gross weight. 5-1-2 tare & preset tare tare when weighing a sample that must be held in a container, taring stores...

  • Page 9

    Vetek weighing ab jcl 7 4) press key smpl to save, and then press key zero to return to the weighing mode. 5-2-1 upper & lower quantity limit checking 1) under the weighing mode, press and hold key mc/ck to initial upper/lower limits setting. (“ ” is blinking. ) 2) use numeric keys to set the upper/...

  • Page 10

    Vetek weighing ab jcl 8 acai automatic counting accuracy improvement (acai) results in a more accurate count by increasing the reference weight without the need to count additional parts. A higher reference weight is important when there is a risk of inconsistent piece weights or if the reference we...

  • Page 11

    Vetek weighing ab jcl 9 2) here we take jcl-15k as an example. 6-1 single point calibration 1) press and hold key smpl while powering on the scale. 2) input 11 with numeric keys 3) again press key smpl to enter the zero point calibration modes. 4) wait till ― ‖ flashes, press numeric key 1 to select...

  • Page 12

    Vetek weighing ab jcl 10 7. Setting mode 1) turn on the power while pressing key zero and setting mode starts. Note: the following steps (2) ~ (11) do not require to operate in order. 3) press numeric key 0 to shift backlight modes. Options are on, off and onoff. =auto-on with items greater than 9 d...

  • Page 13

    Vetek weighing ab jcl 11 = there will be a warning sound when the quantity of material is less than the preset lower limit and the weight of the material is more than 20 divisions. = no sound alarm. 8) press numeric key 8 to select whether to save previously quantity checking values. . = previously ...

  • Page 14

    Vetek weighing ab jcl 12 8. Serial interface if external interface is needed, please select the proper two-in-one board first, which integrates rtc (time display), rs-232 and relay (weight checking) functional module onto one circuit board. Only when this board is adopted, the three functions can be...

  • Page 15

    Vetek weighing ab jcl 13 data format: kg g/n . W . : +/- k g cr lf weight u . W . : g / p c s cr lf unit weight t o t a l : p c s cr lf pcs example g.W. :+ 2.2352 kg u.W. :+ 0.5352 g/pcs total : 4176 pcs lb g/n . W . : +/- l b cr lf weight u . W . : l b / p c s cr lf unit weight t o t a l : p c s cr...

  • Page 16

    Vetek weighing ab jcl 14 eeprom chksum failure re-sold eeprom or contact our service. The weighed articles are overload. Do not load the item exceeds the maximum tolerance. The accumulated number of weighments, total count or weight exceeds display range. No more accumulation. The quantity of weighe...

  • Page 17

    Vetek weighing ab jcl 15.