  • Page 1

    Installation manual aqualink ® rs all button and onetouch tm control systems warning for your safety - this product must be installed and serviced by a professional pool/ spa service technician. The procedures in this manual must be followed exactly. Failure to follow warning notices and instruction...

  • Page 3: Table of Contents

    Page 3 section 1. Important safety instructions ...... 4 section 2. System overview .......................... 6 2.1 package contents .............................................. 6 2.2 systemcomponentspecifications and dimensions.................................................. 7 2.3 plumbing dia...

  • Page 4

    Page 4 section 1. Important safety instructions read and follow all instructions lire la notice technique. All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precaution...

  • Page 5

    Page 5 caution a ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional ...

  • Page 6

    Page 6 section 2. System overview 2.1 package contents package contents will depend on which aqualink rs system you are installing. All jandy aqualink rs systems come complete with the appropriate number of 3hp relays needed. Control system sub-assemblies all button dual equipment onetouch dual equi...

  • Page 7

    Page 7 2.2 systemcomponentspecificationsanddimensions specifications (usa and canada) power supply 120 vac; 60 hz; 3 a contact rating high voltage - 25 a; 3hp @ 240 vac 1½ hp @120 vac 1500 watts incandescent low voltage - class 2, 1 a @ 24 vac emergency service switch all circuits (located at power ...

  • Page 8

    Page 8 2.3 plumbing diagrams 2.3.1 basic plumbing refer to figure 1 when plumbing two separate sets of equipment. The basic setup consists of one pump, filter and heater for the pool and another set for the spa. Figure 1. Basic plumbing for dual equipment 2.3.2 plumbing - sharing one heater when the...

  • Page 9: Section 3.  Power Center

    Page 9 section 3. Power center connection (low voltage) 3.1 connecting power and mounting bezel warning risk of electric shock which can result in serious injury or death. Before attempting installation or service, ensure that all power to the circuit supplying power to the system is disconnected or...

  • Page 10

    Page 10 3.4 connecting heater to low voltage terminal note millivolt, electronic ignition, or heat pump with thermostatic circuitry of 24 vac or less. 1. Ifyouareconnectingalowvoltagepool heater (for example, a jandy brand heater), connect two 14 gauge wires, designed for use in hot environments, to...

  • Page 11: Dip Switch Settings

    Page 11 section 4. Power center pcb dip switch settings 4.1 dip switch functions s1 dip #1 on- aux 1 controls pool cleaner ifyouinstalledaboosterpumpforapoolcleaner, the relay coil for the booster pump must be plugged intotheaux1relaysocket.Ifanon-booster pump cleaner is installed, plug the jva into...

  • Page 12

    Page 12 4.2 dip switch settings for pool and spa combination s1 dip switch # off on 1 aux1= any equipment aux1= pool cleaner 2 aux2= any equipment aux2= low speed for a two-speed filter pump. Filter pump circuit becomes high speed. 3 not used not used 4 heater cool down operates. Heater cool down di...

  • Page 13

    Page 13 4.3 dip switch settings for pool or spa only s1 dip switch # off on 1 aux1= any equipment aux1= pool cleaner 2 aux2= any equipment aux2= low speed for a two-speed filter pump. Filter pump circuit becomes high speed. 3 aux3= any equipment no change 4 heater cool down operates. Heater cool dow...

  • Page 14: Diagram

    Page 14 section 5. Dual equipment wiring diagram figure 5. Dual equipment wiring diagram pool pump relay optional relay optional relay optional relay optional relay spa pump relay aux 1 relay line on e lin e tw o load on e loa d tw o aux 2 relay grounding bar wire nut to 120 vac power system power l...

  • Page 15

    Page 15 notes.

  • Page 16: Limited Warranty

    Sheet #6840, rev . J zodiac pool systems, inc. 6000condordrive,moorpark,ca,usa93021•800.822.7933•fax877.327.1403 litho in u.S.A. © 2009 zodiac pool systems, inc. 0906 this warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from...