Jandy AquaPalm Installation And Operation Manual

Manual is about: Wireless Handheld Remote (For use with AquaLink RS OneTouch and All Button Systems)

Summary of AquaPalm

  • Page 1

    Installation and operation data installation and operation manual aquapalm wireless handheld remote (for use with aqualink ® rs onetouch and all button systems) warning for your safety - this product must be installed and serviced by a professional pool/spa service technician. The procedures in this...

  • Page 3: Table of Contents

    Page 3 table of contents section 1. Important safety instructions ........... 4 section 2. Product description .......................... 6 2.1 basic functions .............................. 6 2.2 aquapalm handheld remote and transceiver j-box dimensions ....... 6 section 3. Installation ..............

  • Page 4

    Page 4 section 1. Important safety instructions read and follow all instructions lire la notice technique. All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precaution...

  • Page 5

    Page 5 caution a ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional ...

  • Page 6: Section 3. Installation

    Page 6 section 2. Product description note for use with an aqualink ® rs system only, software revision “m” or later. This document gives instructions for installing and operating the jandy aqualink ® rs aquapalm. The instructions must be followed exactly. Read through the instructions completely be...

  • Page 7

    Page 7 figure 3. Aquapalm j-box cable connection to power center pcb conduit knockout for low voltage aquapalm j-box wire heyco fittings for low voltage jva and sensor wires low voltage raceway high voltage knockouts for conduit (do not run any low voltage wires through these knockouts) 3.2 aquapalm...

  • Page 8

    Page 8 4. Re-install the cover for the battery chamber and secure with the two (2) screws removed in step 2. 3.4 changing the frequency channel if your aqualink rs aquapalm system is turning items on or off at undesignated times, another aqualink rs aquapalm system may be in close proximity using th...

  • Page 9: Remote Operation

    Page 9 note the default setting for hotkeys 1 and 2 are aux1 and aux2 respectively. However, these buttons can be assigned to any piece of equipment or onetouch mood setting. 6. On the aquapalm handheld remote display screen, a prompt will appear with instructions to slide the j-box learn switch out...

  • Page 10: Remote Menus

    Page 10 4.3 battery status the battery icon , located on the left corner of the display screen, indicates the status of the battery. The aquapalm handheld remote uses two (2) aa batteries. The batteries are located behind the cover on the back side of the handheld remote. If the batteries have full ...

  • Page 11

    Page 11 5.3 filter pump (pool mode) equipment on/off > filter pump the filter pump selection turns the main filtration pump on or off for circulation to the pool. The filter pump also activates if the spa is turned on, if the pool cleaner is turned on, or if the spa spill-over effect is activated. T...

  • Page 12

    Page 12 5.5 pool heat equipment on/off > filter pump > pool heat > (set to desired temperature) the pool heat selection enables the heater for the pool. It uses the setting from set temp menu, or you can increase/decrease when enabling. Equipment filter pump spa pool heat spa heat solar heat aux 1 a...

  • Page 13

    Page 13 5.7 solar heat equipment on/off > solar heat the solar heat selection controls solar heating. A solar heating system and optional solar sensor are required for solar heat selection to operate and must be part of the normal circulation system. Note if a solar sensor is not installed, extra au...

  • Page 14

    Page 14 5.9 set temperature menu menu > set temp > pool or spa > set temp value the set temp menu allows you to preset the pool and spa thermostats. Note for pool/spa combination systems, the default pool temperature is 80°f and the default spa temperature is 102°f. For pool only/spa only systems, t...

  • Page 15

    Page 15 5.12 auto shut-off menu menu > palm options > set auto-off > set time the auto-off feature of the handheld remote can be set to a two (2) minute, five (5) minute, or ten (10) minute auto shut off. The display can be re-enabled by pressing the power on/off button. Note aquapalm default is set...

  • Page 16

    Page 16 figure 26. Boost menu - start to change the hotkeys setting highlight menu and press select. Highlight palm options and press select. Highlight assign hotkeys and press select. Highlight 1 or 2 and press select. Use the up/down arrow keys to change the setting. Then press the select button t...

  • Page 17

    Page 17 5.17 aquapalm handheld remote menu flow chart set time set month, day, year & time aquapalm options set auto-off backlight assign hotkeys set aquapure set output % boost start go back equipment on/off select equipment on off all off light on light off 2 minutes 5 minutes 10 minutes 1 2 oneto...

  • Page 18: Section 6. Troubleshooting

    Page 18 section 6. Troubleshooting 6.1 aquapalm quick troubleshooting guide the aqualink rs aquapalm will stop communicating anytime interference (such as a 900 mhz device) prevents a valid signal transmission. When communication is lost the aquapalm handheld remote will lock on the startup screen u...

  • Page 19

    Page 19 notes.

  • Page 20: Limited Warranty

    Limited warranty thank you for purchasing jandy ® pool and spa products. Jandy pool products, inc. Warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase, with the following exceptions: • aqualink ® rs units ins...