Service manual & parts list mc7700 qcp.
Service access face plate and top cover ............................................................................................................ 1 belt cover .............................................................................................................................................
1 service access (1) face plate top cover [to remove] 1. Open the face plate. Remove the setscrews (b), (c) and (d). Raise the carrying handle and remove the top cover. [to attach] 2 follow the above procedure in reverse. [to remove] 1. Remove the setscrews (a) (2 pcs.) to remove the face plate. [to...
2 service access (2) belt cover [to remove] 1. Remove the setscrew (a). Loosen the setscrews (b) and (c). Remove the belt cover. [to attach] 2. Follow the above procedure in reverse. Setscrew (b) setscrew (a) belt cover setscrew (c).
3 machine base [to remove] 1. Remove the setscrews (a) (4 pcs.). Remove the machine base. [to attach] 2. Follow the above procedure in reverse. Base cover [to remove] 1. Remove the setscrews (b) (4 pcs.). Remove the base cover. [to attach] 2. Follow the above procedure in reverse. Bed cover [to remo...
4 free-arm cover [to remove] 1. Remove the machine base and bed cover (see page 3). Remove the needle plate. 2. Remove the setscrew (a) and pin. Unlock the hook (a) and (b) from the inside. Remove the tab (a) and (b) from the holes. Slide the free-arm cover to the left to remove the free-arm cover. ...
5 [to remove] 1. Remove the top cover, machine base, base cover and free-arm cover (see pages 1, 3 and 4). 2. Loosen the setscrews (a), (b), (c), and (d). Unlock the rear cover hooks (e) from the front cover. Remove the connectors from the circuit board a (see page 20). Remove the front cover. [to a...
6 [to remove] 1. Remove the top cover, machine base, base cover and free-arm cover (see pages 1, 3 and 4). 2. Remove the setscrews (a) (6 pcs.). Unlock the rear cover hook from the front cover. Remove the rear cover. [to attach] 3. Follow the above procedure in reverse. Rear cover setscrews (a) sets...
7 mechanical adjustment needle drop position when the straight stitch is selected, the needle should be at the center of the hole of the needle plate. When the maximum zigzag width (7.0) is selected, the distance between the needle and the edge of the hole of the needle plate at the right and left n...
8 setscrew e setscrew b presser bar height and alignment (1) when the presser foot is lifted, the distance between the surface of the needle plate and the bottom of the zigzag foot should be 6 mm. Setscrew (a) led lamp needle bar supporter spring 1. Attach the zigzag foot a. Adjust the presser foot ...
9 with the block (a) removed, the presser foot will be lowered needle plate 6.6 mm 6.0 mm washer no gap gap block (a) presser foot lifter setscrew (h) presser bar supporter presser bar height and alignment (2) 8 place the block (a) (6.6 mm) between the presser foot and needle plate. (the presser foo...
10 1. Loosen the setscrew on the rotation stopper while the presser foot holding the block (a) (see page 9 for the block (a)). Adjust the direction of the presser bar. The gap between the block and the rotation stopper must be 0.3 mm. 2. Remove the block (a). Lower the presser foot to check the dire...
11 1. Remove the machine base (see page 3). 2. Turn the power switch on and select stitch pattern ( ) . 3. Set the zigzag width at “0.0” and turn the power switch off. 4. Remove the presser foot, needle plate and bobbin holder. 5. Turn the handwheel toward you to lower the needle bar at its lowest p...
12 1. Turn the power switch on and select stitch pattern ( ). 2. Set the zigzag width at “0.0” and turn the power switch off. Remove the top cover (see page 1). 3. Open the face plate. Remove the presser foot, needle plate, and bobbin holder. 4. Turn the handwheel toward you until the tip of the hoo...
13 mechanical adjustment clearance between needle and rotary hook the clearance between needle and the tip of the rotary hook (j) should be between –0.1 and +0.05 mm [adjustment ii] 1. Remove the base cover and bed cover (see page 3). 2. Turn the power switch on, and select the stitch pattern . Adju...
14 a a a a a b b b b b mechanical adjustment 1. Remove the base cover (refer to page 3) 2. Remove the needle, needle plate and bobbin holder. 3. Loosen the hexagonal socket screw (d). 4. If the backlash is too much, turn the lower shaft bushing in direction a. If the backlash is too little, turn the...
15 nut setscrew (a) adjusting screw (b) presser foot 0.80 – 0.90mm surface of needle plate feed dog hexagonal socket screw (i) left-handed setscrew (d) threaded hole (c) [adjustment i] 1. Turn the power switch on. Adjust the stitch length at maximum length. Turn the power switch off. 2. Remove the b...
16 1. Set the thread tension dial (a) to “auto”. 2. Open the face plate. Adjust the tension by turning the thread tension adjusting screw. To loosen the tension, turn it clockwise. (in the direction of “–”) to tighten the tension, turn it counter clockwise (in the direction of “+”). Thread tension d...
17 thread tension unit replacement [to remove] 1. Open the face cover. Remove the top cover. 2. Remove setscrew (a) and (b). Remove the thread tension unit. [to attach] 3. Reverse the procedure above. Check the thread tension (see page 16). Adjust the thread tension mechanism (see page 18). Setscrew...
18 1. Open the face plate. Remove the top cover (see page 2). 2. Lower the presser lifter. 3. Adjust the thread tension dial at “9”. Loosen the setscrew (a). 4. Press the tension release plate to the disk holder. 5. Tighten the setscrew (a). Raise the presser foot lifter. Make sure the tension disks...
19 mechanical adjustment setscrew (a) setscrew (a) printed circuit board “f” replacement [to remove] 1. Remove the front cover (see page 5). 2. Pull out the connector from the printed circuit board a (see page 21). 3. Remove setscrwes (a) and printed circuit board f. [to attach] 4. Follow the above ...
20 circuit board “a” replacement [to remove] 1. Remove the front cover (see page 5). 2. Remove the connectors (5 pcs) from the circuit board a. Remove the setscrews (3 pcs). Remove the circuit board a. [to attach] 3. Reverse the above procedure. Setscrew setscrew setscrew connectors circuit board a ...
21 printed circuit board f (black) zigzag stepping motor (white) m line sensor (red) dc motor (white) foot control (white) touch panel (white) bobbin winder spindle (blue) auto thread cutter motor (white) phase sensor (black) printed circuit board a solenoid 1 thread tension release (white) slide vo...
22 needle threader plate replacement [to remove] 1. Remove the foot holder. 2. Pull out the threader plate unit (a). [to attach] 3. Push the threader plate unit (a) up to snap it with the pin (b) as shown in fig. I. 4. Attach the foot holder [adjustment] 5. If the threader hook thrusts or hits again...
23 1. Remove the needle plate. Loosen the hexagonal nut. 2. Adjust the distance of the lower side of thread drawing lever from the surface of the hook race to 5.5 –6 mm by moving the thread drawing lever up or down. 3. Tighten the hexagonal bolt 4. Attach the needle plate. Thread drawing lever 5.5 –...
24 [to check] 1. Turn the power on. Select the stitch ( ). 2. Press the stitch length adjusting key. Adjust the stitch length to “0”. Turn the power switch off. 3. Lower the feed dogs. 4. Remove the machine base and belt cover (see page 2 and 3). 5. Check if the bed and upper feed lower shaft rear a...
25 [to check] 1. Attach the dual feed foot. 2. Set the upper feed dog. Turn the power switch on. Select the stitch ( ). 3. Press the stitch length adjusting key. Adjust the stitch length to “0”. 4. Lower the feed dog. Remove the top cover 5. Set the upper feed dog adjusting dial to “0”. 6. Lower the...
26 the clearance between the lower edge of the needle eye and the upper surface of the needle plate should be 0.9 mm. Upper feed dog height adjustment 1. Remove the face plate and top cover. 2. Remove the front bracket (unit) and needle bar supporter spring (see page 8). 3. Loosen the setscrew (a). ...
27 to replace driving motor driving motor replacement [to remove] 1. Remove the front cover and belt cover. (see page 2 and 5) 2. Remove the motor belt. 3. Pull out the connector from the circuit board a. 4. Remove the 2 setscrews (a) and pull out the driving motor. [to attach] 5. Tighten the 2 sets...
28 lower shaft shield plate position adjustment when the machine is set for zigzag stitch, the needle should start to swing 7.7 to 8.7 mm above the surface of the needle plate. 1 while pressing the needle up/down and lock stitch buttons, turn the power switch on. The lcd screen display “factory adju...
29 [to check] 1. While pressing the needle up/down and lock stitch buttons, turn the power switch on. The lcd screen will display “factory adjust”. 2. Turn the jog dial to select “06. Sensor”. Press the confirm button. 3. Turn the jog dial to select “m line”. Press the confirm button. The needle pos...
30 bh lever sensor buttonhole lever position adjustment 1. While pressing the needle up/down and lock stitch buttons, turn the power switch on. The lcd screen will display “factory adjust”. 2. Turn the jog dial to select “06. Sensor”. Press the confirm button. 3. Open the face plate. Lower the butto...
31 presser bar lifter switch position adjustment 1. While pressing the needle up/down and lock stitch buttons, turn the power switch on. 2. Turn the jog dial to select “06. Sensor”. Press the confirm button. 3. Remove the top cover (see page 1). 4. When the presser bar is at normal up position , the...
32 thread cutter sensor position adjustment when the thread cutter motor is initialized, the distance between the edge of moving cutter and the end of thread cutter plate slit should be in the range of 0.4 to 1.2 mm. [to check] 1. Turn off the power switch. Remove the base cover, bed cover and free-...
33 setscrew setscrew setscrew cord holder switching power supply connector switching power supply replacement [to remove] 1. Remove the top cover, front cover, rear cover, belt cover and free-arm cover. (see page 1, 2, 5 and 6) 2. Pull out the power switch connector (white) from the circuit board a....
34 solenoid position adjustment when the tension disk is closed, the clearance between the plunger and the end of yoke should be 2.0 mm. Mechanical adjustment [adjustment] 1. Remove the top cover (see page 1) 2. Loosen the setscrews a. 3. Adjust the clearance between the plungr and the yoke to 2 mm ...
35 (a) (b) 33 – 39 mm (a) (b) adjustment of stretch stitch feed balance adjust the stretch stitch balance dial (c) at the setting mark (d). The measurement of five of test pattrens should be in the range of 33 to 39 mm as shown in fig. 1. [to adjust] 1. While pressing the needle up/down and lock sti...
36 1 3 2 diagnosis test to start the diagnosis test 1. While pressing the needle up/down and lock stitch buttons, turn the power switch on. The lcd screen display “factory adjust”, then adjusting screen will appear. 2. Turn the jog dial to select “03.Self-check”. 3. Press the confirm button. Note: 1...
37 step 1 (lcd display) step 2 (function of buttons) step 3 (detecting switch) [correct condition] 1) lcd display and led blink at 1 second interval. 2) sewing light turns on. Press the reverse stitch button to proceed to the next step. [correct condition] (1) bobbin winding switch (spool) bobbin wi...
38 step 4 (speed control lever and foot control) slide volume [correct condition] move the speed control lever slowly. The display shows when the lever is: at the left end: 000-008 at the right end: 1012-1024 foot control [correct condition] connect the foot control to the machine. The display shows...
39 step 6 (phase check) 1) turn the handwheel toward you. The “phase state” changes “bm”, “–”, “fm” and “–” in order. “--” to “bm” when the phase state is at “bm”, and confirm button is pressed, zigzag width motor and cutting motor will be initialized. When the phase state is at “fm”, and confirm bu...