Jbc DR 5650 Reference Manual - English
ENGLISH
2
DR 5650 Ref.5650000
Desoldering tip
Heating element
Pushbutton vacuum pump
Vacuum hose
Desoldering iron cable
Solder tin deposit
Metal
Glass
Cartridge fixing screw
-
The condition of the filter must be checked
and replaced if dirty or damaged.
-
The deposit needs to be inserted with
spiral filter put into place. Then the whole
must be closed by screwing the lid shut.
Lid
Brush
Ref. 0786640
Filter Ref.0780840
Deposit
Spiral
To empty the solder tin deposit and change
the filter (vertical position)
For this, the lid needs to be unscrewed and first
the tin deposit with the desoldering in vertical
position, and then its spiral must be removed to
clean the inner part of the deposit with a brush.
Change of desoldering tip
This operation should be done while the tip is
hot, at a minimum temperature of 250°C, so
that any tin left inside is in molten state.
- Unscrew the tip to be replaced, with the aid
of the spanner supplied.
- Fit the new tip, and tighten up with the
spanner to achieve a good air tightness.
Ref. 0780550
- Fit the new tip, and tighten up with the
spanner to achieve a good air tightness.
-
Do not file the tips or use abrasive tools
which may damage the tip's protective
surface coating and avoid knocking them
about.
-
If th tip has been a long time without being
tinned, use a metal brusch to remove any
dirt and oxid.
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT: DO NOT press the pushbutton
vacuum pump while tinning the desoldering
tip, as the fumes given off by the flux would
quickly soil the ducts and filter of the air
circuit.