Temp
º
C
Air %
Time to stop 45 seconds
Power 70%
400 85
400
ºC Select
Temp
º
C
º
C
Program 8
380
Air 100%
Time 125s.
6
7
Position the extractor with the
appropriate suction cup and
press the suction button.
Heat the component by
pressing the heater button.
The component lifts off
automatically when the
solder melts.
Access Menu (pess key 2 seconds) & Confirm Selection
Selected temperature
Current temperature
% Instant power supplied
to heater
You can switch between operating modes (Manual Mode / Program Mode) by pressing the
“increase” and “decrease” keys simultaneously for 2 seconds. (Only when Program mode is ON)
Manual Mode
Decrease program
number
Increase program
number
Selected program
Current temperature
Selected flow
Graph of selected
program
Remaining time
Program Mode
Edit Program
This option allows you to edit or create a program.
First, you must select the program to edit and then modify the points that make up the program.
Each program is composed of 9 points, each point consisting of 3 parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
You can delete the last point of the program by selecting “-----” in the time parameter.
It should be taken into account that the regulation range permitted by the station is between 150°C
and 450°C, so it is not possible to create temperature ramps between room temperature (Toff) and
150°C.
The station can store up to 25 temperature programs.
The first three programs are edited as an example.
Copy Program
This option allows you to copy a program.
You must select the program source and the program destination (where it will be copied).
Delete Program
This option will allow you to delete a previously selected program.
Operation
Process Control
3. Releasing
1. Placing
2. Heating
www.jbctools.com
6