JDS Technologies HomeRunner RBI User Manual - page 30
30 HomeRunner RBI User Manual – Rev 1.03a
To name the event, click on the default event name and select “Edit Event Name.” This will
highlight the existing name (New Event 0001) in the left side Event Name list. Type the name you
want to replace it with (Desk Lamp ON), then click anywhere or press “Enter.” You can also
double-click on the name in the left side Event Name list or right-click and select “Edit Event
Name” to edit the name. The new name will then appear in the left side Event Name list as well as at
the top of the event in the schedule to the right.
Rather than create the second event from scratch, we can simply copy and paste the first event, then
edit the pasted copy with the correct values.
To Copy and Paste the first event, click on the event name (Desk Lamp ON), then select “Copy
Event” (or type “Ctrl C”).Then click in the workspace above or below and select “Paste
Event(s)” (or type “Ctrl V”).
Next, click on the name of the pasted event (“Desk Lamp ON (1)”) and select “Edit Event Name.”
Change the name “Desk Lamp ON (1)” to “Desk Lamp OFF” then click anywhere or press
“Enter.”
Next, click on the If statement (TIME equals 06:00:00 PM Mon,Tue,Wed,Thu,Fri) and select
“Edit.” Change the time setting to “Equals 11:30:00 PM Weekdays” then click OK. TheIf
statement now reads: “TIME: Equals 11:30:00 PM Mon,Tue,Wed,Thu,Fri.”
Next, click on the Then statement (INSTEON Device: Desk Lamp ON at 100%”) and select
“Edit.” Change the Device action from “ON” to “OFF” then click OK. TheThen statement now
reads: “INSTEON Device: Desk Lamp OFF.”
Your two-event schedule is now ready to be uploaded to the HomeRunner RBI controller, but first
let’s name it. Click “Schedule” then click “Save Schedule As” then type a name in the “File name”
box (for example: “Home”) and click “Save.”
Special Cases: Crossing Over Midnight And New Year
When creating events based on a range of times that cross over midnight or dates that cross over the
new year, care must be taken to use the correct logic type. To HomeRunner RBI, a “Time is After”
condition is considered true from one second past the specified time up to and including 11:59:59
PM. A “Time is Before” condition is considered true from 12:00:00 AM (midnight) up to and
including one second before the specified time. Since it can never be before midnight AND after
midnight, you must use OR logic when crossing over midnight.
Example:
//Cross Over Midnight
If
Time is After 6:00:00 PM Sun,Mon,Tue,Wed,Thu,Fri,Sat
or Time is Before 1:00:00 AM Sun,Mon,Tue,Wed,Thu,Fri,Sat
Then
X10: [A-1] Porch light ON
Else
X10: [A-1] Porch light OFF
In the above event, the Porch light will be ON from 6:00:01 PM through 12:59:59 AM and OFF from
1:00:00 AM through 6:00:00 PM.