Jeanneau SUN ODYSSEY 42 DS Owner's Manual - page 22
18/132
5.3.3 i) ISO 10 240, ISO 9094-1
LOCATION OF THE FIRE EXTINGUISHERS (ISO 9094-1)
An extinguisher or a fire blanket shall be set less than 2 m from any flame appliance.
Other locations are possible, the extinguishers shall be less than 5 m from all the berths.
An extinguisher shall be compulsorily set less than 2 m away from the extinguisher aperture.
An extinguisher shall be less than 1 m from the steering station.
WARNING
The extinguishers are part of the compulsory
equipment.
Extinguisher, per unit, minimum capacity
5 A/34 B.
For the SUN ODYSSEY 42 DS: 10 A/68 B
(2 extinguishers at least).
1. Against mast bulkhead
2. Under map table
3. In aft cabin
4. In cockpit locker
5. Extinguisher aperture of the engine
compartment
Emergency exits in case of fire
A. Deck hatch(es)of the forward cabin(s)
B. Deck hatch of the saloon
C. Companionway