- DL manuals
- Jelrus
- Furnace
- Infinity L-30
- Operator's Manual
Jelrus Infinity L-30 Operator's Manual - page 23
INFINITY M-30 (ALL VOLTAGES)
INFINITY L-30 100, 115 VOLT
INFINITY L-30 220/230, 240 VOLT
22
Figure 4
INFINITY WITH UPPER REAR PANEL REMOVED
Heating Plate Wire
Power Terminal
Heater (Power) Leads
Rear Insulating Panel
Thermocouple
Thermocouple Clamp
Ceramic Insulating
Bushing
Insulating Filler
Rear Insulating Panel
Thermocouple
Thermocouple Clamp
Ceramic Insulating
Bushing
Insulating Filler
Heating Plate Wire
Power Terminal
Heater (Power) Leads
Jumper
Heating Plate Wire
Power Terminal
Heater (Power) Leads
Jumper
Insulating Filler
Ceramic Insulating
Bushing
Thermocouple Clamp
Thermocouple
Rear Insulating Panel
Summary of Infinity L-30
Page 1
I n f i n i t y b u r n o u t f u r n a c e s tm operator’s manual a6732 iso 13485:1996 iso 9001:2000 air techniques inc. Hicksville, ny.
Page 2: Table Of Contents
1 introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 . Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 safety ....
Page 3: Warranty
Thank .You .For .Purchasing .An .Infinity burnout furnace . . . We .Have .Designed .And .Manufactured .This .Furnace .Using .The .Latest .In .Microcomputer .Technology .To .Give .You .Many . Years .Of .Dependable .Service . .The .Controls .On .Your .New .Infinity .Are .Different .From .Those .You .M...
Page 4: Specifications
Specifications infinity m-30 infinity l-30 electrical 100v . 50/60hz . 1150w 115v . 50/60hz . 1150w 220/230v . 50/60hz . 1150w 240v . 50/60hz . 1150w 100v . 50/60hz . 1610w 115v . 50/60hz . 1610w 220/230v . 50/60hz . 1610w 240v . 50/60hz . 1610w capacity .8-1 .3/4” .Rings .Or .2-3” .Rings 15-1 .3/4”...
Page 5
Display description 1 . . Night .Time . . . Press .To .Start .A .Delayed .Program . .The .Number .Entered .Is .The .Time . . . (delay .Start) . . . Required .For .The .Program .To .Be .Completed .And .Ready .To .Cast . . . . . . . . . . . When .A .Program .Is .Running, .Press .To .Display .The .Time...
Page 6
5 figure 1 infinity m-30 and l-30 identification 13 10 11 9 8 7 6 5 12 4 3 2 1 front panel heating chamber vent tube key parts identification and explanation.
Page 7
Key parts identification and explanation lower back panel (figure 2) display description 1 . . Power .Cord . A . .On .100v .And .115v .Furnaces, .The .Ac .Power .Cord .Is .Permanently . . . . Connected .To .The .Unit . . . B . . On .220/230v .And .240v .Furnaces, .The .Ac .Power .Cord .Is .Detachabl...
Page 8: Installation
Unpack and set-up installation 7 1 . . Unpack .The .Contents .Of .The .Box . .Remove .The .Following .Materials: . A . .Vent .Tube .- .Remove .From .Bubble .Wrap .And .Insert .In .Hole .On .Top .Of .Furnace . . B . .Calibration .Table .Kit .- .Remove .Plastic .Bag .Containing .Two .Tablets .And .Sav...
Page 9: Installation
Installation 8 when .A .Program .Is .Completed, .20 ."beeps" .Sound .Every .15 .Minutes .To .Remind .The .Operator .That .The . Material .Is .Ready .To .Cast . 1 . . .Be .Sure .The .Infinity .Is .In .The .Idle .Mode .- .No .Program .Us .Running . 2 . . .Press . . . .And .(while .Holding) .Press .Pro...
Page 10: Operation
Program and operate - one stage program .(figure .1) 9 operation 1 . . Turn .The .Power .Switch .On . 2 . . Press .Program .Number . . .Use . . . . . . . .To .Display .The .Desired .Program .Number .(p1 .- .P30) . 3 . . Press .Enter ./ .Review .To .Select .The .Displayed .Program .Number . .Stage .1...
Page 11: Operation
Operation program and operate - two stage program (figure .1) 10 1 . .Follow .One .Stage .Program, .Steps .1 .- .6 . 2 . .Press .Enter ./ .Review . . .Stage .1 .Light .Turns .Off, .Stage .2 .And .Heat .Rate .Lights .Turn .On . . .Main . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 12: Operation
Operation program and operate - three stage program (figure .1) 11 1 . .Follow .Two .Stage .Program, .Steps .1 .- .4 . 2 . .Press .Enter ./ .Review . . .Stage .2 .Light .Turns .Off, .Stage .3 .And .Heat .Rate .Lights .Turn .On . . .Main . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 13: Operation
Operation program and operate - four stage program (figure .1) 12 1 . .Follow .Three .Stage .Program, .Steps .1 .- .4 . 2 . .Press .Enter/review . . .Stage .3 .Light .Turns .Off, .Stage .4 .And .Heat .Rate .Lights .Turn .On . . .Main . . . .Display .Shows .Four .Heat .Rate .Choices . . .Choose .One:...
Page 14: Operation
Operation review a program (figure .1) 13 1 . . .Turn .The .Power .Switch .On . 2 . . .Press .Program .Number . 3 . . .Press . . . . . . . .To .Select .The .Program .Number .To .Be .Reviewed . . .The .Program .Number .(p1 .- .P30) . . . . .Will .Appear .On .The .Main .Display . 4 . . The . Number . ...
Page 15: Operation
Operation edit while a program is running (figure .1) 14 1 . . .To .Identify .Which .Program .Is .Running, .Press .Program .Number . Note: the program number cannot be changed using while the program is running. 2 . . .To .Determine .The .Time .Remaining .For .The .Completion .Of .The .Program, .Pre...
Page 16: Operation
Night time delay start operation sample one stage program (to .Be .Completed .And .Ready .To .Cast .In .24 .Hours) . Heat rate temp hold time stage 1 stage 2 stage 3 stage 4 24:00 10 °f .(6°c) 1600 °f .(871°c) 1:00 no no no * .* .* * .* .* * .Though .Any .Number .May .Appear, .The .Unit .Is .Deactiv...
Page 17: Operation
To .Start .Immediately, .Press .Start ./ .Stop . Follow .The .Same .Programming .Procedures .If .A .Three .Or .Four .Stage .Program .Is .Desired . Press .Night .Time .(delay .Start) .To .Start .An .Overnight .Burnout . . .(see .Sample .On .Stage .Program .To .Pro- gram .Night .Time .(delay .Start) ....
Page 18: Error Codes
Error codes note: . .“beeps” .Occur .When .The .Error .Code .Appears .On .The .Main .Display error code description probable cause invalid .Entry . Error: . .Stage, . Heat .Rate .And . Temp .Lights .Flash occurs . When . The . Heat .Rate . Is . Set . To . Cool . But . The . Temp . Of . That . Stage ...
Page 19: Error Codes
Error codes error code description probable cause shorted . Thermocouple . Or .Defective . . Heater .Plates occurs .If .The .Thermocouple .Wires .Are .Shorted .Or .The .Heater .Plates .Are . Defective .Causing .Infinity .To .Achieve .A .Heat .Rate .Of .Less .Than .6% .Of .The . Maximum .Attainable ....
Page 20: Service
19 caution: the infinity should be serviced only by qualified service technicians. Be sure to unplug the power cord and wait for the furnace to cool before performing any service oper- ation. For help with operating or servicing your jelrus equipment, please call jelrus any time between 9:00am and 5...
Page 21: Service
20 1 . . If .A .Power .Failure .Occurs, .The .Infinity .Memorizes .The .Conditions .Prior .To .The .Loss .Of .Power . . .When .The .Power . . . . . Returns, .The .Infinity .Returns .To .The .Proper .Point .In .The .Program . . 2 . . When .Power .Is .Returned, .The .Hr:min .Light .Flashes .Indicating...
Page 22: Field Service
1 . . Remove .The .Back .Panel .Of .The .Furnace . 2 . . Remove .The .Nuts .Which .Hold .The .Heating .Plate .Wires .To .The .Power .Terminals .And .Straighten .The .Heating . . Plate .Wires .(figure .4) . 3 . . Open .The .Furnace .Door .And .Find .The .Two .Ceramic .Sections .At .The .Front .Of .Th...
Page 23
Infinity m-30 (all voltages) infinity l-30 100, 115 volt infinity l-30 220/230, 240 volt 22 figure 4 infinity with upper rear panel removed heating plate wire power terminal heater (power) leads rear insulating panel thermocouple thermocouple clamp ceramic insulating bushing insulating filler rear i...
Page 24: Field Service
1 . . Remove .The .Front .Panel .(figure .5) . 2 . . Note .And .Record .The .Color .And .Location .Of .Each .Wire .On .The .Thermocouple .Terminals .Located .On .The .Main . Pc .Board . .Remove .Both .Wires . 3 . . Remove .The .Calibration .Jack .Connector .(j1) .From .The .Main .Pc .Board .By .Pull...
Page 25
Figure 5a other components 24 figure 5 infinity with front panel / main pc board removed.
Page 26: Field Service
1 . . Remove .The .Bottom .Front .Panel .And .The .Upper .And .Lower .Rear .Panels .Of .The .Furnace . .(note .The .Position .Of . . . The .Vent .Louvers .On .The .Rear .Panels .) 2 . . Note .And .Record .The .Color .And .Location .Of .The .Wires .On .The .Thermocouple .Terminals .Located .On .The ....
Page 27: Field Service
Field service replacement of the triac (pn 15475) 26 1 . . Remove .The .Lower .Rear .Panel .(figure .2) . 2 . . Note .And .Record .The .Color .And .Location .Of .Each .Of .The .Three .Wires .On .The .Triac .Terminals . (figure .5a) . .Remove .Each .Of .The .Three .Wires .By .Pulling .Straight .Up .O...
Page 28: Spare Parts List
27 spare parts list description 100v 115v 220/230v 240v power .Cord .Kit-japan .& .U .S . . 15288 . 15288 . N/a . N/a power .Cord .Kit-australia . N/a . N/a . 23206 . 23206 power .Cord .Kit-england . N/a . N/a . 23202 . 23202 power .Cord .Kit-europe . N/a . N/a . 23203 . 23203 power .Cord .Kit-italy...
Page 29: Spare Parts List
28 spare parts list description 100v 115v 220/230v 240v power .Cord .Kit-japan .& .U .S . . 15289 . 15289 . N/a . N/a power .Cord .Kit-australia . N/a . N/a . 23206 . 23206 power .Cord .Kit-england . N/a . N/a . 23202 . 23202 power .Cord .Kit-europe . N/a . N/a . 23203 . 23203 power .Cord .Kit-italy...
Page 30: Program Card Forms
Program card forms stage 1 stage 2 stage 3 stage 4 heat temp hold rate time program # metal(s) stage 1 stage 2 stage 3 stage 4 heat temp hold rate time program # metal(s) stage 1 stage 2 stage 3 stage 4 heat temp hold rate time program # metal(s) stage 1 stage 2 stage 3 stage 4 heat temp hold rate t...
Page 31: Program Card Forms
Program card forms stage 1 stage 2 stage 3 stage 4 heat temp hold rate time program # metal(s) stage 1 stage 2 stage 3 stage 4 heat temp hold rate time program # metal(s) stage 1 stage 2 stage 3 stage 4 heat temp hold rate time program # metal(s) stage 1 stage 2 stage 3 stage 4 heat temp hold rate t...
Page 32
Pn .15813 .Rev . .E infinity .Is .A .Trademark .Of .Air .Techniques .Inc . ©2004 .Air .Techniques .Inc . Jelrus international, .A .Division .Of .Air .Techniques .Inc ., .Has .Been .A .Leading .Manufacturer .Of dental .Laboratory .Equipment .Essential .To .The .Fabrication .Of .Porcelain .Caps, .Crow...