JEM HEAVY FOG GLACIATOR User Manual - page 2
NOTE! The JEM warranty will be void if any fluid other than JEM
approved fluid is used. If other fluids are used there could be serious
damage to the machine and the fluid may not have been tested for use
in public areas.
Fluids Suitable for this system:
Heavy Fog
Fluid B2
Heavy Fog
Fluid C3
HEAVY FOG GLACIATOR
CONNECTIONS
HEAVY FOG GLACIATOR
17
REMOTE
INTERF
ACE
1-GND, 2-12V OUT, 3-INPUT
1 FOG
2 STANDBY
3 TIMER
4 FAN
5 SPECIAL
6 GND
DMX
ADDRESS
1
2
4
8
16
32
64
128
256
SPECIAL 1
SPECIAL 2
SPECIAL 3
ON
1
2
3
4
5
6
7
8
9
10
11
12
DMX
DA
T
A
INPUT
IN
OUT
1
5
6
9
1 GND
2 COLD
3 HOT
FUSE RATINGS
The Heavy Fog Glaciator uses
four fuses.
They should be replaced with
the value and type detailed
below:
DMX receiver low voltage
2AT
Power PCB
12AT
Compressor control relay
12AT
Main input fuse
20AT
Three of these fuses are
located internally and should
not be accessed without first
disconnecting the power supply.
FILTERS
The Heavy Fog Glaciator uses
a washable synthetic fibre filter
in the air intake for the
condenser unit (located at the
top of the machine). This can
be removed for cleaning by
removing the ventilation grill
above it (two M5 screws). Use
the following guidelines for
when to check the filter.
:
Inspect and clean/replace every
250 hours
:
Inspect and clean/replace every
150 hours
Normal Conditions
Severe Conditions