SPECIFICATION
HEAT EXCHANGER
2.5KW heater (240V)
Wide bore steel vaporizing coil
Ceramic thermal trip for over-temperature protection
Electronic Temperature control using thermocouple
FLUID SYSTEM
Oscillating piston high pressure fluid pump
Low fluid detection by electronic sensor
9.5L fluid containers (2.5 US Gal.)
DMX512 decoder:
Required Channels = 2
Output is proportional for all levels above 12%
Channels supported = 1 to 511
Valid start codes = 0 (dimmer data only)
Full framing error detection implemented
Analogue control via standard JEM Multifunction Contoller.
Optional PLC interface for simple switching control of the system.
CONTROL PANEL
2 x LED displays with 4 button keypad
Output level control from 0 to 100% for Fog
Timer range:
Delay time (toF) 0 seconds - 90 seconds
Run time (ton) 0 seconds - 90 seconds
REFRIGERATION UNIT
2/3 HP compressor with thermostatic control
Uses refrigerant R404A (0.850 Kg)
OUTPUT CONNECTION
Ducting adaptor to accept 150mm (6”) flexible ducting
POWER REQUIREMENTS
Input voltage 200 - 250vac
Input power (max) 3.1Kw
Main fuse 20AT
Frequency 50/60Hz dependant on model.
Maximum fluid consumption 120mL/minute
REMOTE CONTROL OPTIONS
HEAVY FOG GLACIATOR
USER
GUIDE
16
HEAVY FOG GLACIATOR
USER
GUIDE
USER GUIDE CONTENTS
Introduction
2
Features
2
Safety Guidelines
3
Machine Layout
4
Commissioning The Machine
5
Remote Control Options
5
DMX Operation
6
The Display
8
Control Panel Functions
10
The Timer
11
Basic Operation
12
The Fluid System
13
Display Messages
14
Basic Fault Finding
15
Specification
16
Connections
17
Fuse Ratings
17
Filter Maintenance
17
1
©
Martin Professional A/S, Denmark.
2000
All rights reserved. No part of this manual may be reproduced, in any form or
by any means, without permission in writing from Martin Professional A/S,
Denmark.