Manual oPeratIons
Thecontrollerwillstartrunningallstationswiththeselectedruntime.Thetimewilldecrementin
thedisplayandwillsequentiallymovethroughallstations,runningthemforthesamesetperiodof
time.Thisoptionisdesignedsothatitispossibletotestallsprinklersandvalvesthatmakeupthe
irrigationdesign.
Toskiptothenextstationpressthe
button.Togobackastationpressthe
button.Tostop
thesystemtest,changethepositionofthemaindial,to“OFF”.
hint: If you wish to alter the default value from 2 mins to some other value and set this as the new
default time, press the
and
together followed by
button. Then alter the run time using
the
or
buttons. Once the new default time is set press the
button again, and the new
default will now always appear when you select a “manual system test”.
run a ProGraM
Tomanuallyrunacompleteprogramortostackmultipleprogramstorun,rotatethedial
to“Run Program”.Theword“OFF”willbeflashing.
The DiSplay Will ShoW:
Toenableprogram1tostartpressthe
button.
Theicon“OFF”willchangeto“ON”.
Thisprogramhasnowbeenenabledsothatitcanbe
run.Tomakeprogram1run,pressthe
button.
nOtE: So long as there are run times in program 1 then program 1 will start and water the stations
associated with it.
Summary of RPS469
Page 1
Station models - available in 4, 6 or 9 stations. Outdoor model - supplied with 120vac x 24 ac or 240vac (international) x 24vac inbuilt transformer. Optional lead with plug. Instruction manual mid-size irrigation controller www.Krain.Com.
Page 2: Contents
Introduction ............................................ 1 glossary .................................................. 2 key features ............................................ 3 programming instructions introduction ................................................ 4 setautomaticprogram ............
Page 3: Introduction
Rps469isavailablein4,6and9stationconfigurations.Designedtocoverawiderangeof applicationsfromresidentialandcommercialturf,tolightagriculture,andprofessionalnursery. Thiscontrollerhasapossible6separateprogramswithupto36startsperday.Thecontrollerhas a7daywateringschedulewithindividualdayselectionperpro...
Page 4: Glossary
Glossary front mounted sensor switch on/offswitchforeasy accesstooverride terminal cover easytoremovefor easyaccess large high contrast lcd displaysall programminginformation large selection dial navigatesthroughall programminginformation quick program selction key the“p”keyallowsfasterprogram entry...
Page 5: Key Features
Key features 4,6&9stationmodels. Indoor/outdoormodelwithbuilt-intransformer. 6programs,eachofwhichhas6starttimes.Maximumof36starttimesperday. Stationruntimesfrom1minuteto12hours&59minutes. Selectablewateringoptions: -individual7dayselection. -oddorevendayselection. -intervalwateringdayselectionfrome...
Page 6: Programming Instructions
Programming instructions introduction thiscontrollerhasbeendesignedwith6separateprogramstoallowdifferentlandscapeareasto havetheirownindividualwateringschedules.Aprogramisamethodofgroupingstations(valves) withsimilarwateringrequirementstowateronthesamedays.Thesestationswillwater insequentialorderand...
Page 7: Programming Instructions
Programming instructions general tips for easy programming thiscontrollerhasbeendesignedforquickintuitiveprogramming. Rememberthesesimpletipsforhasslefreeprogramming. . Completethesparewateringplanneratthebackofthisbook. . Whensetting,onepushofthebuttonwillincrementoneunit. . Holdingonebuttondownwil...
Page 8: Programming
6 programming set current time & correct day turnthedialto“set clock/calendar”position. Thehourwillbeflashing.Usethe or toadjust. Note: am/pm must be set correctly. Press buttonandthe“minutes”willflash.Use or toadjust theminutes. Press andthe“day of the week”willflash.Use or tosetthe correctday. Set...
Page 9: Example: Set Program 1
Example: set program 1 step 1 – set start times note: all stations will come on in sequential order for each start time. Turnthedialto“set start times”andensurethat“prog no 1”isshowing.Ifnot,thenusethe buttontoselect“prog no 1”. The“startno”willbeflashing. The display will show: use or tochangethe“s...
Page 10: Programming
Programming step 2 – set watering days thisunithasintervalwateringfromeverydaytoevery15thday,individualdayselectionora365 daycalendarwithodd/evendayselectioninareaswherewaterrestrictionsrequirethisfeature. Individual day selection turnthedialto“set watering days”andensurethat“prog no 1”isshowing.Ifn...
Page 11: Programming
Interval day selection pressthe buttonuntilthe“interval days”isflashing. The display will show: “interval 1”willbeflashing.Thismeansthecontrollerwill watereveryday.Thedisplaywillshowhowmanydays areleftbeforeanactiveschedule. Forexample,ifitshowed“1”theninoneday’stimethecontrollerwillrunthisprogram.T...
Page 12: Programming
0 programming continueuntilallthestationsinprogram1havebeensetwitharuntimeorifastation(s)isnot requiredtobeactiveinthisparticularprogram,ensurethattheruntimeissetto“off”. Note: to turn a station “off” press the and at the same time when the station number is flashing or use to set minutes to 00 when...
Page 13: Manual Operations
Manual operations run a single station themaximumruntimeforastationis12hours59minutes.Tomanuallyrunasinglestationonce, turnthedialtothe“system test or run single station”position. The display will show: thedefaultruntimeforasinglestationis10minutes. Advancetotheselectedstationbypressing asmany times...
Page 14: Manual Operations
Manual operations thecontrollerwillstartrunningallstationswiththeselectedruntime.Thetimewilldecrementin thedisplayandwillsequentiallymovethroughallstations,runningthemforthesamesetperiodof time.Thisoptionisdesignedsothatitispossibletotestallsprinklersandvalvesthatmakeupthe irrigationdesign. Toskipto...
Page 15: Manual Operations
Theremaybetimeswhenitisdesirabletorunmorethanoneprogrammanually.Thecontroller allowsthistooccurusingitsuniquefeatureofenablingaprogram,beforerunningit.Forexample ifyouwishtorunprogram1andalsoprogram2,thecontrollerwillmanagestackingoftheprograms sotheydonotoverlap. Enableprogram1bypressingthe button....
Page 16: Manual Operations
Manual operations stop watering tostopanautomaticormanualwateringschedule,turnthedialtothe“off”position. Note: for automatic watering remember to turn the dial back to the “auto run” position, as “off” will stop any future watering cycles from occurring. Stacking start times shouldyouaccidentallyset...
Page 17: Other Features
Other features rain sensor wheninstallingarainsensor,firstremovethethefactory fittedlinkbetweenthe“c”and“r”terminalsshownhere bythewire. Replacewiththetwowiresfromtherainsensorintothese terminals,polaritynotrequired.Movetherainsensor switchonthefasciato“on”. Turnthedialto“set auxiliaries”toenableind...
Page 18: Other Features
6 other features rain sensor (cont.) ifastationisturned“on”thismeansthatthesensorwillcontrolit,shoulditrain.Thedefaultmode isforallstationstoberainsensor“on”.Shouldyouhaveastation(valve)thatalwaysneedstobe watered,e.G.Anenclosedgreenhouseorplantsthatareundercover,thentherainsensorcanbe turned“off”fo...
Page 19: Other Features
Thismeansthatallautomaticscheduleswillnotcomeon, buttheprogrammedinformationisstillretainedinthememory andtheclockstillkeepstrackoftimeeventhoughitisno longerbeingdisplayed. Toreactivatewatering,turnthedialtothe“auto run”position. Water budgeting & seasonal adjustment theautomaticstationruntimescanb...
Page 20: Special Functions
Special functions pump on/off selection inmostsystemsthewatersupplywillbefromawellorfromthemains.Thiscontrollerwillturnon eitherapump(wellsupply)ormastervalve(mainssupply)eachtimeanautomaticormanualstart occurs.Normallythepumpormastervalveisactivatedforallstations.Howeverifthereisadual watersupplyor...
Page 21: Special Functions
Stationno1willnowbeflashinganditwillbeoff. The display will show: thismeansthepumpwillnotturnonwhenstationno1 is running.Toturnthepumponoroffforaparticularstation pressthe buttonsothat“off”isnowflashing.Pressthe buttontoturnthe pumponorpressthe buttontoturnthepumpoffforthatparticularstationnumber. C...
Page 22: Special Functions
0 special functions note: each program can have its own pressure build time programmed. Toalterthepressurebuildtimepressthe button.Thedelaytimeissetto“off”andwillnow flashfortheselectedprogramnumber. Usethe or buttonstoincreaseordecreasethedelaytimeseconds. Thisvaluecanbeanythingfromoffto99seconds. ...
Page 23: Installation Instructions
Installation instructions mounting the controller installthecontrollerneara120vac/240vac(international)outlet.Preferablylocatedinahouse, garageorexteriorelectricaloutlet.Foreaseofoperation,eyelevelplacementisrecommended.Ideally, yourcontrollerlocationshouldnotbeexposedtorainorareaspronetofloodingorh...
Page 24: Glossary
Power supply connections itisrecommendedthatthetransformerisnotconnectedtoa120vac/240vac(international)supply whichisalsoservicingorsupplyingmotors(i.E.Airconditioners,poolpumps,refrigerators).Lighting circuitsaresuitableaspowersources. Thiscontrollerissuitableforoutdoorinstallationasthehousingiswea...
Page 25: Installation Instructions
Installation instructions pump start relay connection (water supply by pump system) thiscontrollerdoesnotprovidepowertodriveapump.Apumpmustbedrivenviaanexternalrelay andcontactorsetupasdetailedbelow.Thecontrollerprovidesalowvoltagesignalthatactuatesthe relaywhichinturnenablesthecontactorandfinallyth...
Page 26: Installation Instructions
Master valve installation thepurposeofthemastervalveistoshutoffthewatersupplytotheirrigationsystemwhen thereisafaultyvalveornoneofthestationsareoperatingcorrectly.It’susedlikeaback-upvalve orfailsafedeviceandisinstalledatthestartoftheirrigationsystemwhereitisconnectedtothe watersupplyline. Installat...
Page 27: Installation Instructions
Installation instructions pump protection (system test) insomecircumstancesnotalloperationalstationsmightbehookedup.Forexample,ifthecontroller wascapableofrunning9stationsbuttherewereonly7fieldwiresandsolenoidvalvesavailablefor connection.Thissituationcanposearisktoapumpwhenthesystemtestroutineforth...
Page 28: Troubleshooting Guide
6 troubleshooting guide suggestion checkfuse,checkfieldwiring, checktransformer. Checksolenoid.Testfieldcableforcontinuity. Testcommoncableforcontinuity. Checksolenoid.Testfieldcableforcontinuity. Testcommoncableforcontinuity. Testconnections. Ifunitworksmanuallythencheckthe programming.Ifnotthenche...
Page 29: Troubleshooting Guide
Suggestion checkwiringandswapfaultystation wire’sonthecontrollerterminalblock withknownworkingstations.Ifthesame outputsarestilllockedon,returnpanel tosupplierormanufacturer. Electriciantocheckvoltageon relayorcontactor. Returnpaneltosupplierormanufacturer. Slideswitchonfrontpaneltotheon position,te...
Page 30: Electrical Characteristics
Electrical characteristics electrical outputs power supply thisunitrunsoffa120vac60hz/240vac50hz(international)singlephasecircuit. Theinternaltransformerreducesthe120vac/240vac(international)toalowvoltagesupplyof24vac. Electricalpowersupply:input24volts50/60hz electricaloutputs:maximumof1.0amp to so...
Page 31: Servicing The Controller
Servicing the controller thecontrollershouldalwaysbeservicedbyanauthorizedagent. Followthesesimplestepstoreturntheunit: . Turnthepowerofftothecontroller. A)ifthecontrollerishardwired,aqualifiedelectricianwillberequiredtoremove theentireunitdependingonthefault. B)returntheentirecontrollerwithtransfor...
Page 32: Spare Watering Planner
0 spare watering planner.
Page 33: Spare Watering Planner
Spare watering planner.
Page 34: Notes
Notes.
Page 35: Notes
Notes.
Page 36: Warranty
Themanufacturerguaranteestotheoriginalpurchaserthatanyproductsuppliedbythemanufacturerwillbe freefromdefectsinmaterialsandworkmanshipforaperiodoftwoyearsfromthedateofpurchase.Anyproduct foundtohavedefectsinmaterialorworkmanshipwithintheperiodofthiswarrantyshallberepairedorreplaced bythemanufacturer ...