Station models - available in 4, 6 or 9 stations. Outdoor model - supplied with 120vac x 24 ac or 240vac (international) x 24vac inbuilt transformer. Optional lead with plug. Instruction manual mid-size irrigation controller www.Krain.Com.
Introduction ............................................ 1 glossary .................................................. 2 key features ............................................ 3 programming instructions introduction ................................................ 4 setautomaticprogram ............
Rps469isavailablein4,6and9stationconfigurations.Designedtocoverawiderangeof applicationsfromresidentialandcommercialturf,tolightagriculture,andprofessionalnursery. Thiscontrollerhasapossible6separateprogramswithupto36startsperday.Thecontrollerhas a7daywateringschedulewithindividualdayselectionperpro...
Glossary front mounted sensor switch on/offswitchforeasy accesstooverride terminal cover easytoremovefor easyaccess large high contrast lcd displaysall programminginformation large selection dial navigatesthroughall programminginformation quick program selction key the“p”keyallowsfasterprogram entry...
Key features 4,6&9stationmodels. Indoor/outdoormodelwithbuilt-intransformer. 6programs,eachofwhichhas6starttimes.Maximumof36starttimesperday. Stationruntimesfrom1minuteto12hours&59minutes. Selectablewateringoptions: -individual7dayselection. -oddorevendayselection. -intervalwateringdayselectionfrome...
Programming instructions introduction thiscontrollerhasbeendesignedwith6separateprogramstoallowdifferentlandscapeareasto havetheirownindividualwateringschedules.Aprogramisamethodofgroupingstations(valves) withsimilarwateringrequirementstowateronthesamedays.Thesestationswillwater insequentialorderand...
Programming instructions general tips for easy programming thiscontrollerhasbeendesignedforquickintuitiveprogramming. Rememberthesesimpletipsforhasslefreeprogramming. . Completethesparewateringplanneratthebackofthisbook. . Whensetting,onepushofthebuttonwillincrementoneunit. . Holdingonebuttondownwil...
6 programming set current time & correct day turnthedialto“set clock/calendar”position. Thehourwillbeflashing.Usethe or toadjust. Note: am/pm must be set correctly. Press buttonandthe“minutes”willflash.Use or toadjust theminutes. Press andthe“day of the week”willflash.Use or tosetthe correctday. Set...
Example: set program 1 step 1 – set start times note: all stations will come on in sequential order for each start time. Turnthedialto“set start times”andensurethat“prog no 1”isshowing.Ifnot,thenusethe buttontoselect“prog no 1”. The“startno”willbeflashing. The display will show: use or tochangethe“s...
Programming step 2 – set watering days thisunithasintervalwateringfromeverydaytoevery15thday,individualdayselectionora365 daycalendarwithodd/evendayselectioninareaswherewaterrestrictionsrequirethisfeature. Individual day selection turnthedialto“set watering days”andensurethat“prog no 1”isshowing.Ifn...
Interval day selection pressthe buttonuntilthe“interval days”isflashing. The display will show: “interval 1”willbeflashing.Thismeansthecontrollerwill watereveryday.Thedisplaywillshowhowmanydays areleftbeforeanactiveschedule. Forexample,ifitshowed“1”theninoneday’stimethecontrollerwillrunthisprogram.T...
0 programming continueuntilallthestationsinprogram1havebeensetwitharuntimeorifastation(s)isnot requiredtobeactiveinthisparticularprogram,ensurethattheruntimeissetto“off”. Note: to turn a station “off” press the and at the same time when the station number is flashing or use to set minutes to 00 when...
Manual operations run a single station themaximumruntimeforastationis12hours59minutes.Tomanuallyrunasinglestationonce, turnthedialtothe“system test or run single station”position. The display will show: thedefaultruntimeforasinglestationis10minutes. Advancetotheselectedstationbypressing asmany times...
Manual operations thecontrollerwillstartrunningallstationswiththeselectedruntime.Thetimewilldecrementin thedisplayandwillsequentiallymovethroughallstations,runningthemforthesamesetperiodof time.Thisoptionisdesignedsothatitispossibletotestallsprinklersandvalvesthatmakeupthe irrigationdesign. Toskipto...
Theremaybetimeswhenitisdesirabletorunmorethanoneprogrammanually.Thecontroller allowsthistooccurusingitsuniquefeatureofenablingaprogram,beforerunningit.Forexample ifyouwishtorunprogram1andalsoprogram2,thecontrollerwillmanagestackingoftheprograms sotheydonotoverlap. Enableprogram1bypressingthe button....
Manual operations stop watering tostopanautomaticormanualwateringschedule,turnthedialtothe“off”position. Note: for automatic watering remember to turn the dial back to the “auto run” position, as “off” will stop any future watering cycles from occurring. Stacking start times shouldyouaccidentallyset...
Other features rain sensor wheninstallingarainsensor,firstremovethethefactory fittedlinkbetweenthe“c”and“r”terminalsshownhere bythewire. Replacewiththetwowiresfromtherainsensorintothese terminals,polaritynotrequired.Movetherainsensor switchonthefasciato“on”. Turnthedialto“set auxiliaries”toenableind...
6 other features rain sensor (cont.) ifastationisturned“on”thismeansthatthesensorwillcontrolit,shoulditrain.Thedefaultmode isforallstationstoberainsensor“on”.Shouldyouhaveastation(valve)thatalwaysneedstobe watered,e.G.Anenclosedgreenhouseorplantsthatareundercover,thentherainsensorcanbe turned“off”fo...
Thismeansthatallautomaticscheduleswillnotcomeon, buttheprogrammedinformationisstillretainedinthememory andtheclockstillkeepstrackoftimeeventhoughitisno longerbeingdisplayed. Toreactivatewatering,turnthedialtothe“auto run”position. Water budgeting & seasonal adjustment theautomaticstationruntimescanb...
Special functions pump on/off selection inmostsystemsthewatersupplywillbefromawellorfromthemains.Thiscontrollerwillturnon eitherapump(wellsupply)ormastervalve(mainssupply)eachtimeanautomaticormanualstart occurs.Normallythepumpormastervalveisactivatedforallstations.Howeverifthereisadual watersupplyor...
Stationno1willnowbeflashinganditwillbeoff. The display will show: thismeansthepumpwillnotturnonwhenstationno1 is running.Toturnthepumponoroffforaparticularstation pressthe buttonsothat“off”isnowflashing.Pressthe buttontoturnthe pumponorpressthe buttontoturnthepumpoffforthatparticularstationnumber. C...
0 special functions note: each program can have its own pressure build time programmed. Toalterthepressurebuildtimepressthe button.Thedelaytimeissetto“off”andwillnow flashfortheselectedprogramnumber. Usethe or buttonstoincreaseordecreasethedelaytimeseconds. Thisvaluecanbeanythingfromoffto99seconds. ...
Installation instructions mounting the controller installthecontrollerneara120vac/240vac(international)outlet.Preferablylocatedinahouse, garageorexteriorelectricaloutlet.Foreaseofoperation,eyelevelplacementisrecommended.Ideally, yourcontrollerlocationshouldnotbeexposedtorainorareaspronetofloodingorh...
Power supply connections itisrecommendedthatthetransformerisnotconnectedtoa120vac/240vac(international)supply whichisalsoservicingorsupplyingmotors(i.E.Airconditioners,poolpumps,refrigerators).Lighting circuitsaresuitableaspowersources. Thiscontrollerissuitableforoutdoorinstallationasthehousingiswea...
Installation instructions pump start relay connection (water supply by pump system) thiscontrollerdoesnotprovidepowertodriveapump.Apumpmustbedrivenviaanexternalrelay andcontactorsetupasdetailedbelow.Thecontrollerprovidesalowvoltagesignalthatactuatesthe relaywhichinturnenablesthecontactorandfinallyth...
Master valve installation thepurposeofthemastervalveistoshutoffthewatersupplytotheirrigationsystemwhen thereisafaultyvalveornoneofthestationsareoperatingcorrectly.It’susedlikeaback-upvalve orfailsafedeviceandisinstalledatthestartoftheirrigationsystemwhereitisconnectedtothe watersupplyline. Installat...
Installation instructions pump protection (system test) insomecircumstancesnotalloperationalstationsmightbehookedup.Forexample,ifthecontroller wascapableofrunning9stationsbuttherewereonly7fieldwiresandsolenoidvalvesavailablefor connection.Thissituationcanposearisktoapumpwhenthesystemtestroutineforth...
6 troubleshooting guide suggestion checkfuse,checkfieldwiring, checktransformer. Checksolenoid.Testfieldcableforcontinuity. Testcommoncableforcontinuity. Checksolenoid.Testfieldcableforcontinuity. Testcommoncableforcontinuity. Testconnections. Ifunitworksmanuallythencheckthe programming.Ifnotthenche...
Suggestion checkwiringandswapfaultystation wire’sonthecontrollerterminalblock withknownworkingstations.Ifthesame outputsarestilllockedon,returnpanel tosupplierormanufacturer. Electriciantocheckvoltageon relayorcontactor. Returnpaneltosupplierormanufacturer. Slideswitchonfrontpaneltotheon position,te...
Electrical characteristics electrical outputs power supply thisunitrunsoffa120vac60hz/240vac50hz(international)singlephasecircuit. Theinternaltransformerreducesthe120vac/240vac(international)toalowvoltagesupplyof24vac. Electricalpowersupply:input24volts50/60hz electricaloutputs:maximumof1.0amp to so...
Servicing the controller thecontrollershouldalwaysbeservicedbyanauthorizedagent. Followthesesimplestepstoreturntheunit: . Turnthepowerofftothecontroller. A)ifthecontrollerishardwired,aqualifiedelectricianwillberequiredtoremove theentireunitdependingonthefault. B)returntheentirecontrollerwithtransfor...
0 spare watering planner.
Spare watering planner.
Notes.
Notes.
Themanufacturerguaranteestotheoriginalpurchaserthatanyproductsuppliedbythemanufacturerwillbe freefromdefectsinmaterialsandworkmanshipforaperiodoftwoyearsfromthedateofpurchase.Anyproduct foundtohavedefectsinmaterialorworkmanshipwithintheperiodofthiswarrantyshallberepairedorreplaced bythemanufacturer ...