Deburralldrilledholes.Removealldebrisfromtheworkareaafterdrillingandbeforeproceeding
furtherwithanyinstallation.DONOTusecompressedairtoremovedebris.Flyingobjectscan
cause serious injury.
Prep Door for Input Unit
1. Temporarily attach the cable routing plate to the front of the door for use as a template, using
thelockmountingscrewstoholditinplace.(SeeFigure9.)
2. Center punch four mounting holes for the Input Unit.
3. Measureandmarkanadditional16mm(5/8")holeforcableroutingapproximately32mm
(11/4")fromthetopofthecableroutingplate.(SeeFigure10.)
4. Removethecableroutingplate.
5. Drillthecableroutingholefortheinputunitusinga14mm16mm(5/8")drillbit.
6. Drillthefourmountingholesfortheinputunitusinga10mm(3/8")drillbit.
Install Lock Body & Input Unit
Note:
ForRoll-UpDoorapplicationsusingaTodco(orWhitingGeneralPurpose)handle,
use the longer 8mm mounting bolts supplied for the bottom two holes of the lock body
and use the longer 6mm mounting bolts supplied for the bottom two holes of the input
unit.
1. Start to attach the two cable routing plates to the inside of the door using two of the lock body
mounting bolts and two lock washers. Attach through the upper right and lower left corners of
the lock body mounting holes.
2. Ontheoutsideofthedoor,placethelockbodygasketoverthetwoboltstoholditinplace.
3. Whileholdingthelockbody,routethecablethroughthegasketandthecableroutingholefor
the lock body.
Fig. 9 - Use Cable Routing Plate as Template
Fig. 10 - Measure & Mark Cable Routing Hole
WARNING
!
1 1/4"