Kaba Mas Gitcon G-152 Installation Manual - page 7
7
Operational Check
PerformtheoperationalcheckpriortoinstallingtheLockassembly.IftheG-152hasbeenpreviously
installed, perform the operational check prior to closing
the door.
Make an operational check of the unit by performing the
followingactions.(SeeFigure15forreference.)
1. Connect the Lock Body and input unit cable.
2. Activatetheinputunitbypressingandreleasingthe
REDswitchbutton.
3. "Open"willappearontheLEDdisplay.
4. Insert (latch) the operating handle locking pin into the
lock body.
5. PressandreleaseREDswitchbutton.
6. PressandreleaseREDbuttonagainwith"UNLK"
prompt.
7. GREENlightflashes.
8. PresentTest Card to input unit transponder "RFID"
communication area.
9. Turn dial on lock body to the left to release the handle.
10. Lift operating handle.
Operational check complete.
Battery Maintenance - Temporary Power
Replace Batteries
The four AA batteries located within the Input Unit should be replaced when the “Battery Low Indicator“
illuminates. To replace batteries, complete the following steps:
1. Removetheinputunitfromthedoor(4mountingbolts)anddisconnectcable.
2. Removethebackplateoftheinputunit(4screws)andthefourAAbatteriesinthebatteryretainer.
ReplacethebatterieswithfournewhighqualityAAlithiumbatteries.Oncethebatteriesareproperly
installed,thelowbatteryindicatorlightwillflash.
3. Reattach the back plate of the input unit.
4. Reconnect the cable and reinstall input unit.
5. Before closing the door, perform an operational check of the lock with the appropriate opening
procedureasdefinedfortheinputunit.
Temporary Power
Anexternal9Vsupplementarypowerconnectorisprovidedtosupplytemporarypowertotheinput
unit. The 9V connector is located at the base of the input unit and is accessible by turning the
knurled knob. It is recommended that you use a new high quality battery.
Fig. 15 - Input Unit Operation
Access to
9 volt connector
Low battery
indicator
Transponder RFID
communication area
IrDA
®
port;
Communication with
Pocket PC/Smart Phone
LED Lights;
Operational
prompts and
lock status
Switch activates
unit and enters
user cdes
LED displays
seal number
and operational
prompts