Kaco 2901xi Operator Instructions Manual - page 7
KACO
Solar
Inc.
6
Operator’s
Instructions
blue
planet
solar generator voltage. Only the “Display” key (1) is active
at this level.
The menus are continuous, i.e. after reaching the last entry
of the menu and pressing the “Display” key (1) the first entry
is displayed again (see Figure 4.).
Figure 4.4.1: Display Mode Menu
If the “Display” key on the inverter is not operated for a
longer period of time, the display will automatically show the
currently fed-in power.
4.5 Set
Mode
Figure 4.5: Set Mode Menu
Set hour and date
The set values are consecutive, i.e. as soon as you have
reached the max. value the display will be reset to the min.
value after pressing the “Display” (1) button once again. The
display for setting the date covers a range up to 2050. After
that, the value will be reset
Clear internal power meter
When clearing the grid-feeding meter, the values for “annual
yield”, “total yield” and “operating hours per year” will be
reset. The required parameter is “2” – please enter it by
means of the “Adjustment” key (2).
Selection of interface and address
Using the menu item “Select interface”, you may change
between the RS232 and RS485 interface by means of the
“adjustment” key (2). If the RS485 interface is enabled, you
can set the address by means of the “Display” key (1).
Using the “Adjustment” key (2) you may set addresses
consecutively from 1 to 32.
The internal power meter can only be
cleared – it is not possible to make
any other adjustments!
To go to level 2 (Adjustment Mode),
keep the “Display” key (1) pressed and
simultaneously press the “Adjustment”
(2) key for approx. 2 seconds.
Using the “Adjustment” key (2) you may
now change the selected parameter.
Depending on the parameter the value
will change after pressing the
“Adjustment” key (2). To return to level
1 (Display Mode), keep the “Display”
key (1) pressed and simultaneously
press the “Adjustment” (2) key.
Keep this key pressed for approx. 2
seconds to select which measured
value should be displayed.
Set time - hour
Set time - minutes
Set date - year
Set date - month
Set date – day
Display of software version
Clear internal power meter
Select and set RS485 interface
address
Display of inverter type
Generator voltage and current
Grid voltage, current and power
Daily peak capacity
Temperature inside the device
Status display
Date and time
Daily yield
Annual yield
Total yield
Operating hours today
Operating hours per year
Total operating hours