Kaco Powador 3200 Operating instructions manual - page 8
Operating Instructions Powador 3200 / 4400 / 5300 / 5500 / 6600_EN
Page 9
4.5
Level 1 menu – Display mode
The display menu is shown once the Powador inverter starts
up. Measured values and all of the counters are displayed
here. Key ”1” is used to navigate through the individual menu
items.
Inverter type display
Generator voltage and current
Grid voltage, current and power
External
limit
Daily peak capacity
Relay 33 remaining time
Temperature inside unit
Yield
counter
Yield
today
Total
yield
(Total) economy of CO
2
Oper. hours cntr
Operating hours today
Total operating hours
Figure 4.4: Display mode menu
Explanation of the individual menu items:
Inverter type display
Display of the inverter type
Powador 3200 / 4400 / 5300 / 5500 / 6600
Generator voltage and current
The current voltage and current of the PV array that is con-
nected to the inverter.
Grid voltage, current and power
The current grid voltage, grid current and the power that is
currently being fed into the grid.
External limit
Power regulation according to the specifi cations of the
German Renewable Energies Act (EEG) to 60%, 30% or 0%.
Daily peak capacity
The peak power of the day in question that was fed into the
grid for a short time.
Relay 33 remaining time
Displays the remaining time for the Relay 33 function. This is
displayed only when the ”Relay 33” function is activated and
the potential-free contact is connected in ”Relay 33” mode.
The display format is hh:mm.
Temperature inside unit
Displays the current heat sink temperature in °C. The unit
switches off if it becomes too hot.
Yield counter
This counter totals all yields until it is reset again. The cus-
tomer can confi gure the time periods for this counter, e.g. as a
monthly counter. The counter can be cleared in the ”Clear
yield” confi guration mode.
Yield today
The power that has been fed into the grid during the current
day.
Total yield
The power that has been fed into the grid since start-up of the
inverter. The initial value can be set in the confi guration mode.
(Total) economy of CO
2
Shows the CO
2
savings of this PV system compared to the
German electricity mix. The CO
2
savings are calculated from
the total yield and can also be cleared with this counter
(1 kWh corresponds to 0.56 kg of CO
2
savings).
Oper. hours cntr
This counter totals all yields until it is reset again. The cus-
tomer can confi gure the time periods for this counter, e.g. as a
monthly counter. It can be cleared in the ”Clear yield” confi gu-
ration mode.
Operating hours today
Today’s hours of operation. As soon as the inverter is in
standby mode (i.e. when LED (1) lights up), the running time is
added up.
Total operating hours
The hours of operation since start-up of the inverter. As soon
as the inverter is in standby mode (i.e. when LED (1) lights up),
the running time is added up.
In addition, all status messages are integrated into this level:
As long as they are present, they are a part of the menu,
which means that they appear again after you have scrolled
completely through level 1. They are automatically
•
cleared when the DSP (Digital Signal Processor) shows a
fault-free status, or
•
replaced when the DSP transmits a status that results in
another message.
They appear only in level 1. If they occur while the menu
system is in another level, they are saved and displayed when
you have returned to level 1 as long as they are still present.
S e c t i o n 4 ·
O p e r a t i o n