KAL-FIRE TWIN 38x15 Installation And Operating Instructions Manual

Manual is about: TWIN gas log fire

Summary of TWIN 38x15

  • Page 1

    Installation and operating instructions twin gas log fire 38 * 15 50 * 15 80 * 15 2 table of contents inleiding 4 1 installation instructions 5 1.1 i nstructions 5 1.2 g eneral requirements 6 2 montage instructies 7 2.1 g as tap 7 2.2 e lectric point 7 2.3 f lexibele connection of gas control unit t...

  • Page 2

    3 4.3.2 e xtinguishing the burners 22 5 dimensions 23 6 trouble shooting 24 6.1 s olutions flowchart - twin maual control 24 6.2 s olutions flowchart – twin ultrasound 25 6.3 s olutions flowchart - twin radio 26 7 warranty certificate 27 7.1 w arranty conditions 28 7.2 t he warranty is not applicabl...

  • Page 3

    5 1 installation instructions 1.1 instructions prior to connecting the gas log fire, please carefully observe the following instructions: • connecting of this gas log fire must be carried out exclusively by a registered installer and this in accordance with the national and/or local regulations. Bef...

  • Page 4

    7 2 montage instructies attention: all parts have to be mounted maintenance friendly. All parts have to be accessible at all times for the maintenance service !!! 2.1 gas tap the gas control system with burner have to be connected behind a gas tap, which at all times can be operated. 2.2 electric po...

  • Page 5

    9 • test leak tightness of the system by means of soapsuds or leakage testing spray. • check the protection system by activating the security; the appliance should go out. Assembly instruction electric wiring this remote control is mains dependent. The receiver part has to be connected to an earthed...

  • Page 6

    11 2.7 positioning of the chips and logs the chips cover the whole of the twin’s cover plate. The flame can be influenced by the quantity of chips used. A small quantity will allow more air to pass through, producing wilder flames. Using a lot of chips will produce a steady flame and a red glow. The...

  • Page 7

    13 for the de twin 80x15: this is the set of logs you have received: the set of logs is to be positioned as follows: 1 3 4 6 7 8 9 10 2 5 1 3 4 6 7 8 9 10 2 5 14 2.8 extra accesoires 2.8.1 optional set of logs for the twin 5015 extra accessoires can be ordered. It is possible to order an optional se...

  • Page 8

    15 there are 2 types of sunken casings available: sunken casing 75 sunken casing 78 attention: place no electronics in the sunken casing !! 742 332 112 782 332 112 534 540 gas90004tw-75 gas90003tw smg 16 model nl be/fr de at/ch/gb/it propaan type b11 / b21 b11 / b21 b11 / b21 b11 / b21 b11 / b21 gas...

  • Page 9

    17 4 operating instructions the twin gas log fire’s are available with three types of controls. There are appliances with manual control, ultrasound remote control and radio remote control. 4.1 manual controlled appliances 4.1.1 lighting the burners make sure the gas tap is turned on. The main burne...

  • Page 10

    19 4.2 appliances with ultrasound remote control 4.2.1 lighting the burners make sure the gas tap is turned on. The main burner in the fire is ignited by a pilot light, which in turn is ignited by a piezo element. Once the pilot light is lit, it heats up a thermocouple which creates a small flow. Th...

  • Page 11

    21 4.3 appliances with radio remote control take the battery-protection strip out of the manual transmitter and check that the battery is still correctly positioned between the two contacts. Plug into the electric socket and turn on the gas tap. 4.3.1 lighting the burners when the big flame (figure ...

  • Page 12

    23 5 dimensions gas log fire twin 50x15: gas log fire twin 80x15: 24 6 trouble shooting 6.1 solutions flowchart - twin maual control twin is ignition sparking? Ignition sparks, does the pilot light go on? Does the pilot light come on when ignition button is held pushed in and being released after 20...

  • Page 13

    25 6.2 solutions flowchart – twin ultrasound is ignition sparking? Ignition sparks, does the pilot light go on? Does the pilot light come on when ignition button is held pushed in and being released after 20 sec.? Burner bed comes on the thermocouple is broken. Contact your dealer. Check that igniti...

  • Page 14

    27 7 warranty certificate this document is valid only i fit can be produced togehter with dated proof of purchase, and therefore it should be kept in a safe place. Customer’s name and adress customer :_________________________ street :_________________________ zipcode :_________________________ type...

  • Page 15

    29 7.2 the warranty is not applicable in the following cases: 1. For appliances with remote control: when the electronics are not installed outside the fire and its radiation range, and are not installed to be fully insulated. 2. If the above requirements are not, or are only partially, satisfied. 3...

  • Page 16

    31 annex 2: electrical connection with fan connection diagram with inatherm rsvg and efc21 control unit • with thermal reflux safety cut-out • with controlled ventilation regulator vk4100m5000b s4565df1068b honeywell s4565df1068 1 2 3 4 l 5 6 7 8 9 10 11 12 x n auxilia h053 reciever m- m+ l out x1.1...