KanexPro HDSC61D-4K User manual - page 10
Compact Scaler Switcher 6x1
6
Operation Examples:
l
Connect HDMI2, HDMI4, and VGA2 ports with source devices, select HDMI4 to
outputs.
l
Press and hold for the front button SOURCE/AUTO for 3 seconds or more to enter
in auto-switching mode.
l
Connect HDMI3 with a source device, and then it will choose HDMI3 to output.
l
Remove the signal of HDMI3, Compact Scaler Switcher will detect from HDMI1 to
VGA2. And when it detects that HDMI2 is available, it will choose HDMI2 to output.
l
Cut off the power of Compact Scaler Switcher, then reboot. As the unit is in
auto-switching mode, it will choose HDMI2 to output.
4.2 RS232 Control
Here we take the software CommWatch.exe as example.
4.2.1 Control Software Operation
l
Installation Copy the control software file to the computer connected with Compact
Scaler Switcher.
l
Uninstallation Delete all the control software files in corresponding file path.
4.2.2 Basic Settings
Firstly, connect Compact Scaler Switcher with an input device and an output device.
Then, connect it with a computer that is installed with RS232 control software.
Double-click the software icon to run this software. The icon is showed as below:
The interface of the control software is showed as below: