Kantech P345KPMTR Installation Manual

Manual is about: Multi-Technology 125 KHz and 13.56 MHz Readers

Summary of P345KPMTR

  • Page 1

    P345mtr and p345kpmtr multi-technology installation manual 125 khz and 13.56 mhz readers dn1870-0905.

  • Page 2: Table of Contents

    Dn1870-0905 ii p345mtr and p345kpmtr readers installation manual table of contents introduction ................................................................................... 5 features ........................................................................................ 6 mounting ............

  • Page 3: Copyright Information

    Dn1870-0905 1 p345mtr and p345kpmtr readers installation manual copyright information copyright © 2009 tyco international ltd. And its respective companies. All rights reserved. All specifications were current as of publication date and are subject to change without notice. Kantech and the kantech l...

  • Page 4: Country

    Dn1870-0905 2 fcc digital device limitations this device complies with part 15 of the fcc rules class a. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may...

  • Page 5: Ul Standards Compliance

    Dn1870-0905 3 p345mtr and p345kpmtr readers installation manual in order to maintain compliance with fcc regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and television reception. Ca...

  • Page 6: Equipment)

    Dn1870-0905 4 • etsi en300 330-2 : electromagnetic compatibility and radio spectrum matters (erm); short range devices (srd); radio equipment in the frequency range 9 khz to 25 mhz and inductive loop systems in the frequency range 9 khz to 30 mhz; part 2: harmonized en under article 3.2 of the r&tte...

  • Page 7: Introduction

    Dn1870-0905 5 p345mtr and p345kpmtr readers installation manual introduction the p345mtr contactless readers will read prox and smart cards at frequencies of both 125 khz and 13.56 mhz. The reading capability includes, for smart cards, both unencrypted serial numbers and encrypted mifare® programmed...

  • Page 8: Features

    Dn1870-0905 6 features • universal compatibility with most 125 khz prox (including all ioprox xsf and hid® prox formats), all iso 15693, and iso 14443a credentials (badges, disk tags and key fobs). Reads both 125 khz and 13.56 mhz credentials in the same reader. • electrical protection (reverse pola...

  • Page 9

    Dn1870-0905 7 p345mtr and p345kpmtr readers installation manual figure 2: mounting assembly with isolation spacer (optional) please note that figure 2 shows the p345mtr reader and cover plate. Although the p345kpmtr keypad reader and front cover plate differ, the mounting assembly is the same as the...

  • Page 10: Installation Considerations

    Dn1870-0905 8 installation considerations the p345-spacer isolation spacer may be used to improve the read range distance when mounting the reader to a metal surface. To optimize reader range, use the number of backplates as indicated in table 2 . Use of isolation spacers is optional and not require...

  • Page 11: Wiring

    Dn1870-0905 9 p345mtr and p345kpmtr readers installation manual wiring p345mtr models have twelve terminals as noted in table 3 . The terminal strip is removable for easy installation and wiring. When attaching wires to the connector, strip off only the minimum insulation required (approx. 1/8'') an...

  • Page 12: Installation Notes

    Dn1870-0905 10 installation notes unless otherwise specified in this manual, please follow these guidelines: important: use only shielded cabling for connections. 1 connect the reader to the controller. See figure 3 for connecting the reader to a kantech controller. Note: you can use a local power s...

  • Page 13: Troubleshooting

    Dn1870-0905 11 p345mtr and p345kpmtr readers installation manual troubleshooting if the operation of a component is in doubt, substitute a known good component and retry the system. Always verify wiring against the provided wiring information before powering up the reader. Table 5: error conditions ...

  • Page 14: Technical Specifications

    Dn1870-0905 12 technical specifications cable recommendations 4 core (minimum), shielded, 22 awg (minimum) cable connectors 12 position, 3.5 mm screw terminals - plug-in certifications fcc part 15, ce and ul 294 open standards compliance iso 14443a iso 14443b (depending on specific implementation) i...

  • Page 15

    Dn1870-0905 13 p345mtr and p345kpmtr readers installation manual read range 1 to 5 in. (2.5 to 12.7 cm) depending on credential technology and environment. Note: read range for credentials of identical technologies may vary greatly depending on the tuning and antenna structure of each individual cre...

  • Page 16

    Copyright © 2009 tyco international ltd. And its respective companies. All rights reserved. Www.Kantech.Com dn1870-0905.