Karcher HDS 601 C Eco Operating Instructions Manual - page 9
English
HDS 601 C
9
–
Securing spray pistol
Illustration 8, Illustration 12
–
Engage spray lance in cover
holder
–
Roll up high-pressure hose and
cable and place in compartment
*
Take care not to kink high-
pressure hose and cable!
Frost will destroy unit if water is not
drained off completely!
Store unit in a frost-free location
Observe the following if the unit is
connected to a flue:
Danger of damage caused by cold
air entering through the flue.
Disconnect unit from flue at outside
temperatures below 0°C.
Take unit out of service if frost-free
storage is not possible.
DISCONTINUATION OF USAGE
In the event of lengthy periods of
non-use or if frost-free storage is not
possible:
–
Drain off water and flush out
equipment with antifreeze
–
Drain cleaning fluid tank
Drain off water
–
Unscrew water supply hose and
high-pressure hose
–
Unscrew supply line at boiler base
and allow heating coil to drain
–
Run unit for max. 1 min until pump
and lines are empty
Flushing unit with anti-freeze
–
Use commercial grade antifreeze
–
Observe handling instructions of
antifreeze manufacturer
–
By this means, a certain degree of
corrosion protection is achieved
MAINTENANCE
*
Disconnect unit from mains before
carrying out any maintenance or
repair work.
*
Always use genuine spare parts
Shut off unit before performing any
work, refer to AFTER USE.
–
Set mode selector switch to "0"
–
Pull power plug out of socket
–
Shut off water supply
–
Actuate handgun to depressurise
unit.
–
Detach water connection
–
Allow unit to cool down
Please consult your KÄRCHER
dealer for details of regular safety
inspection/maintenance
agreement
Maintenance intervals
Once a week
–
Clean strainer in water connection
–
Check oil level
Contact KÄRCHER AFTER-SALES
SERVICE immediately if oil is
opaque!
Once a month
–
Clean strainer in low water
protection
–
Clean filter at cleaning-agent
suction hose
After 500 hours of operation, at
least once a year
–
Change oil
MAINTENANCE TASKS
Cleaning strainer in water
connection
Fig. 18
–
Remove strainer
–
Clean in water and re-insert
Cleaning strainer in low water
protection
Fig. 19
–
Unfasten union nut and detach
hose
Fig. 20
–
Take out strainer
If necessary, screw in bolt M8
approx. 5mm to pull out strainer.
–
Clean strainer in water
–
Slide in strainer
–
Mount hose
–
Tighten union nut
Cleaning filter at cleaning-agent
suction hose
Fig. 17
–
Pull out cleaning-agent suction
hose
–
Clean filter in water and re-insert