Keating Of Chicago pre 2000 series Manual - page 13
1-800-KEATING
|
GAS GRIDDLE - SERIES 2000
11
SERVICE DIAGNOSIS
The following diagnosis is only to be used as a guide to qualifi ed service personnel. Keating recommends that
you use a qualifi ed & licensed service company. (Equipment still under warranty requires it.)
NOTE: To correctly and quickly diagnose the system, the chart below should be followed in sequential order.
TROUBLE SHOOTING CHART
PROBLEM
PROBABLE CAUSE
SOLUTION
No pilot
a. Gas supply not “ON”.
b. Air in gas lines.
c. Quick disconnect not engaged.
d. Gas valve is on “OFF” position.
e. Faulty piezo ignitor.
a. Open gas supply valve.
b. Press gas valve knob in “pilot” position
and hold.
c. Reconnect quick disconnect.
d. Turn valve knob to “pilot”.
e. Replace ignitor.
Pilot won't stay on
a. Loose wires.
b. Faulty thermopile.
c. Inadequate gas supply.
d. Bad gas valve.
a. Tighten connections on all wires.
b. Replace thermopile.
c. Increase line pressure.
d. Replace gas valve.
Pilot on but no main burner ignition
a. ON/OFF switch is in “OFF” position.
b. Gas valve is in “pilot” position.
c. Thermostat is not turned on.
d. Low gas pressure.
e. Gas valve failure.
a. Put ON/OFF switch in “ON” position.
b. Turn knob to “ON” position.
c. Turn thermostat to desired
temperature.
d. Set manifold pressure to 4" WC (nat),
10" WC (LP).
e. Replace valve.
Temperature of griddle is erratic
a. Thermostat is not calibrated.
b. Air from exhaust hood excessive.
a. Calibrate thermostat with exhaust
system running.
b. Have exhaust hood inspected and air
fl ow balanced.
Griddle stays hot or overheats
a. Thermostat is not calibrated.
b. Thermostat failure.
c. Air from exhaust hood excessive.
d. Improper cooking procedure.
a. Calibrate thermostat.
b. Replace thermostat.
c. Have exhaust hood inspected and air
fl ow balanced.
d. See Cooking Procedure Section.
Burners will not shut off
a. Thermostat is not calibrated.
b. Thermostat failure.
c. Bad gas valve.
a. Calibrate thermostat.
b. Replace thermostat.
c. Replace gas valve.
Flames pulsate
a. Low gas pressure.
b. Orifi ce is dirty or clogged.
c. Air from exhaust hood excessive.
a. Set manifold pressure to 4" WC (nat),
10" WC (LP). Set line pressure to
7" WC (nat), 11" WC (LP).
b. Clean orifi ce.
c. Have exhaust hood inspected and
airfl ow balanced.