Check the serial plate to determine if the burner is set
up for the proper type gas before connecting the quick-
disconnect or piping from the building gas supply pipe.
A. Gas pressure at manifold
NATURAL GAS – 4.0 in. W.C.
B. Gas pressure at manifold
LP GAS – 10 in. W.C. (2.49kPa)
C. Maximum incoming gas pressure
NATURAL GAS – 7 in. W.C. (2.01kPa)
D. Maximum incoming gas pressure
LP GAS – 11 in. W.C. (2.98kPa)
E. Connect incoming gas.
LIGHTING INSTRUCTIONS MIRACLEAN® GRIDDLE
(See lighting instructions plate attached to front of
Miraclean® Griddle).
Make sure that the main gas valve on the gas supply
line to the Miraclean® Griddle is in the “ON” position.
1. Turn gas valve knob to "pilot" position.
2. Push gas valve knob inwards and push the red
spark ignition button to light the pilot. Then hold
the knob for 90 seconds.
3. Release the pilot gas valve knob; pilot should
remain burning. Turn the knob to the ON
position.
4. Turn ON/OFF switch to ON position.
5. Set thermostat knob to desired position.
AIR IN THE SUPPLY LINE MAY REQUIRE A LONGER
THAN NORMAL PERIOD OF TIME TO LIGHT YOUR
MIRACLEAN® GRIDDLE DURING INITIAL INSTALLATION,
AFTER OVERNIGHT SHUTDOWN, OR WHEN
RELIGHTING.
A 5 MINUTE COMPLETE SHUT OFF PERIOD IS
REQUIRED BEFORE APPLIANCE IS RELIT
DO NOT LEAVE YOUR MIRACLEAN® GRIDDLE
OPERATING UNATTENDED.
SHUT DOWN INSTRUCTIONS
1. Turn ON/OFF switch to "off" position.
2. Rotate thermostat knob to left to "OFF"
position.
3. Turn gas valve knob to "OFF" position.
4. Check to determine that all burners and pilots
are
extinguished.